ASTM B231 Reliable AAC Bare Conductor for Utility and Infrastructure Projects

Product Details
Customization: Available
Application: Construction, Overhead, Underground, Industrial,
Customization: Available
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 30 days
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
CCC
to see all verified strength labels (22)
  • ASTM B231 Reliable AAC Bare Conductor for Utility and Infrastructure Projects
  • ASTM B231 Reliable AAC Bare Conductor for Utility and Infrastructure Projects
  • ASTM B231 Reliable AAC Bare Conductor for Utility and Infrastructure Projects
  • ASTM B231 Reliable AAC Bare Conductor for Utility and Infrastructure Projects
  • ASTM B231 Reliable AAC Bare Conductor for Utility and Infrastructure Projects
  • ASTM B231 Reliable AAC Bare Conductor for Utility and Infrastructure Projects
Find Similar Products

Basic Info.

Model NO.
AAC
Voltage
Low and Medium Voltage Cable
Certification
ISO, CCC, ASTM
Transport Package
Wooden Drum, Steel Drum, Steel&Wooden Drum, Pallet
Specification
ASTM B231
Trademark
Xunda Cable
Origin
Henan
HS Code
7614900000
Production Capacity
5000 Tons/Month

Product Description

AAC-All Aluminum Conductor
ASTM B231 Reliable AAC Bare Conductor for Utility and Infrastructure Projects
ASTM B231 Reliable AAC Bare Conductor for Utility and Infrastructure Projects
ASTM B231 Reliable AAC Bare Conductor for Utility and Infrastructure Projects



DESCRIPTION
AAC-All aluminum Conductors has the characteristics of simple structure, convenient erection and maintenance, low cost, large transmission capacity, good conductivity, sufficient mechanical strength and high tensile strength. Concentric lay stranded Aluminium Conductors (AAC) are made out of Hard-Drawn aluminum wires. 

APPLICATION
AAC is used mainly in urban areas where the spacing is short and the supports are close. All aluminium conductors are made up of one or more strands of aluminium wire depending on the end usage. AAC is also used extensively in coastal regions because it has a high degree of corrosion resistance.
ASTM B231 Reliable AAC Bare Conductor for Utility and Infrastructure Projects

STANDARDS ASTM B231
 
Code Name Area Number of Wires Diameter of Wire Approx. Overall Diameter Unit Weight Nominal Breaking Load Nominal DC Resistance at 20ºC
Nominal Actual
AWG or MCM mm2 No. mm mm kg/km kN ohm/km
PEACHBELL 6 13.3 7 1.56 4.68 36.6 2.53 2.1606
ROSE 4 21.1 7 1.96 5.88 58.2 3.91 1.3619
IRIS 2 33.6 7 2.47 7.41 92.6 5.99 0.855
PANSY 1 42.4 7 2.78 8.34 116.6 7.3 0.6779
POPPY 1/0 53.5 7 3.12 9.36 147.2 8.84 0.5373
ASTER 2/0 67.4 7 3.5 10.5 185.7 11.1 0.4262
PHLOX 3/0 85 7 3.93 11.79 233.9 13.5 0.3379
OXLIP 4/0 107.2 7 4.42 13.26 295.2 17 0.268
VALERIAN 250 126.7 19 2.91 14.55 348.6 20.7 0.2268
SNEEZEWORT 250 126.7 7 4.8 14.4 348.8 20.1 0.2268
LAUREL 266.8 135.2 19 3.01 15.05 372.2 22.1 0.2126
DAISY 266.8 135.2 7 4.96 14.88 372.3 21.4 0.2126
PEONY 300 152 19 3.19 15.95 418.3 24.3 0.189
TULIP 336.4 170.5 19 3.38 16.9 469.5 27.3 0.1686
DAFFODIL 350 177.3 19 3.45 17.25 487.9 28.4 0.1621
CANNA 397.5 201.4 19 3.67 18.35 554.9 31.6 0.1427
GOLDENTUFT 450 228 19 3.91 19.55 627.6 35 0.126
SYRINGA 477 241.7 37 2.88 20.16 664.8 38.6 0.1189
COSMOS 477 241.7 19 4.02 20.1 664.8 37 0.1189
HYACINTH 500 253.3 37 2.95 20.65 696.8 40.5 0.1134
ZINNIA 500 253.3 19 4.12 20.6 697.1 38.9 0.1134
MISTLETOE 556.5 282 37 3.12 21.84 775.7 44.3 0.1019
DAHLIA 556.5 282 19 4.35 21.75 775.8 43.3 0.1019
MEADOWSWEET 600 304 37 3.23 22.61 836.3 47.5 0.0945
ORCHID 636 322.3 37 3.33 23.31 886.9 50.4 0.0892
HEUCHERA 650 329.4 37 3.37 23.59 907.4 51.7 0.0872
FLAG 700 354.7 61 2.72 24.48 975.8 57.1 0.081
VERBENA 700 354.7 37 3.49 24.43 975.7 55.4 0.081
NASTURTIUM 715.5 362.6 61 2.75 24.75 998.5 58.4 0.0793
VIOLET 715.5 362.6 37 3.53 24.71 998.5 56.7 0.0793
 
Code Name Area Number of Wires Diameter of Wire Approx. Overall Diameter Unit Weight Nominal Breaking Load Nominal DC Resistance at 20ºC
Nominal Actual
AWG or MCM mm2 No. mm mm kg/km kN ohm/km
CATTAIL 750 380 61 2.82 25.38 1046 60.3 0.0756
PETUNIA 750 380 37 3.62 25.34 1046 58.6 0.0756
LILAC 795 402.8 61 2.9 26.1 1110 63.8 0.0713
ARBUTUS 795 402.8 37 3.72 26.04 1109 61.8 0.0713
SNAPDRAGON 900 456 61 3.09 27.81 1256 70.8 0.063
COCKSCOMB 900 456 37 3.96 27.72 1256 68.4 0.063
GOLDENROD 954 483.4 61 3.18 28.62 1331 75 0.0594
MAGNOLIA 954 483.4 37 4.08 28.56 1331 72.6 0.0594
CAMELLIA 1000 506.7 61 3.25 29.25 1394 78.3 0.0567
HAWKWEED 1000 506.7 37 4.18 29.26 1395 76.2 0.0567
LARKSPUR 1033.5 523.7 61 3.31 29.79 1442 81.3 0.0549
BLUEBELL 1033.5 523.7 37 4.25 29.75 1441 78.8 0.0549
MARIGOLD 1113 564 61 3.43 30.87 1553 87.3 0.0509
HAWTHORN 1192.5 604.2 61 3.55 31.95 1662 93.5 0.0476
NARCISSUS 1272 644.5 61 3.67 33.03 1774 98.1 0.0446
COLUMBINE 1351 684.6 61 3.78 34.02 1884 104 0.042
CARNATION 1431 725.1 61 3.89 35.01 1997 108 0.0396
GLADIOLUS 1510.5 765.4 61 4 36 2108 114 0.0375
COREOPSIS 1590 805.7 61 4.1 36.9 2216 120 0.0357
JESSAMINE 1750 886.7 61 4.3 38.7 2442 132 0.0324
COWSLIP 2000 1013 91 3.77 41.47 2787 153 0.0284
SAGEBRUSH 2250 1140 91 3.99 43.89 3166 167 0.0255
LUPINE 2500 1267 91 4.21 46.31 3519 186 0.0229
BITTERROOT 2750 1393 91 4.42 48.62 3872 205 0.0208
TRILLIUM 3000 1520 127 3.9 50.7 4226 223 0.0191
BLUEBONNET 3500 1773 127 4.22 54.86 4977 261 0.0165
 
ASTM B231 Reliable AAC Bare Conductor for Utility and Infrastructure Projects
Industry Solutions
Power grid
New energy
Building
Industry
Marine cable
Telecommunication
Railway
Instrument


Our Certificate
ASTM B231 Reliable AAC Bare Conductor for Utility and Infrastructure Projects
Company Information


ASTM B231 Reliable AAC Bare Conductor for Utility and Infrastructure ProjectsASTM B231 Reliable AAC Bare Conductor for Utility and Infrastructure ProjectsASTM B231 Reliable AAC Bare Conductor for Utility and Infrastructure ProjectsASTM B231 Reliable AAC Bare Conductor for Utility and Infrastructure Projects
FAQ


1.Q:Are you a factory or trading company?
A: Manufacturing base in Henan ,China, with more than 150 workers.

2.Q:How can I visit there?
A: Sure,lf you need,we will arrange the driver to pick you up.

3.Q:How can I get some samples?
A: Contact me on below,Determine sample and address for shipping.

4.Q:Have you ever supplied cables to our country?
A: Xunda Cable have been sold to over 30 countries and regions in the world. you cancontact me for details.

5.Q:What is your MOQ?
A: MOQ Normally 1km for insulated cables(1 ton for bare conductor).Please contact mefor detail info if you have specific cable requirement.

6. Q:When can l get the price?
A: Usually quote within 3hours after we get your inquiry.

7.Q:How long is your delivery time?
A: According to your order's quantity.Usually our lead time is 3 - 20 working days.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier