The conductor consists of a phase conductor and a neutral conductor. The material of the phase conductors is Aluminum or copper and may be solid, stranded circular compacted or compressed or uncompressed conductor. The neutral conductors are stranded round circular uncompressed aluminum or copper or aluminum-alloy conductor or ACSR or ACSR/AW etc. And the insulating material is black weather or UV-resistant thermoplastic polyethylene (PE) or cross-linked polyethylene (XLPE).
Note: Neutral conductors can be insulated or non-insulated.
Application
Conductor: Stranded,Circular compacted ,Circular compressed AAC or AAAC.
Insulation: Cross-linked polyethylene (XLPE),Black color,Weather and UV resistant.
Designation | Average Thickness of Insulation (prescribed value) | Core | |||||||
Nature | Nominal Section | No. of Wires | Max. DC Resistance at 20 0C | Conductor | Breaking Force | Outside Diameter | |||
Diameter | |||||||||
(mm2) | No. | (Ω/km) | Min. (mm) | Max. (mm) | Min. (daN) | (mm) | Min. (mm) | Max. (mm) | |
Phase or neutral or public lighting | 16 | 7 | 1.91 | 4.6 | 5.1 | 190 | 1.2 | 7 | 7.8 |
25 | 7 | 1.2 | 5.8 | 6.3 | 300 | 1.4 | 8.6 | 9.4 | |
35 | 7 | 0.868 | 6.8 | 7.3 | -- | 1.6 | 10 | 10.9 | |
50 | 7 | 0.641 | 7.9 | 8.4 | -- | 1.6 | 11.1 | 12 | |
70 | 12 | 0.443 | 9.7 | 10.2 | -- | 1.8 | 13.3 | 14.2 | |
95 | 19 | 0.32 | 11 | 12 | -- | 1.8 | 14.6 | 15.7 | |
120 | 19 | 0.253 | 12 | 13.1 | -- | 1.8 | 15.6 | 16.7 | |
150 | 19 | 0.206 | 13.9 | 15 | -- | 1.8 | 17.3 | 18.6 | |
Neutral | 54.6 | 7 | 0.63 | 9.2 | 9.6 | 1660 | 1.6 | 12.3 | 13 |
70 | 7 | 0.5 | 10 | 10.2 | 2050 | 1.6 | 12.9 | 13.6 | |
95 | 19 | 0.343 | 12.2 | 12.9 | 2750 | 1.6 | 15.3 | 16.3 |
No. of Cores and Section | No. of Wires | Nominal Insulation Thickness | Approx. Diameter | Max. DC. Resistance at 20ºC | Approx. Weight |
of Cable | |||||
mm2 | No. | mm | mm | Ω/km | kg/km |
2x16 | 7 | 1.2 | 14.4 | 1.91 | 131 |
2x25 | 7 | 1.4 | 17.6 | 1.2 | 200 |
2x35 | 7 | 1.6 | 20.4 | 0.868 | 273 |
2x50 | 7 | 1.6 | 22.6 | 0.641 | 350 |
2x70 | 12 | 1.8 | 26.8 | 0.443 | 495 |
2x95 | 19 | 1.8 | 30.4 | 0.32 | 656 |
2x120 | 19 | 1.8 | 32.8 | 0.253 | 799 |
4x16 | 7 | 1.2 | 17.4 | 1.91 | 262 |
4x25 | 7 | 1.4 | 21.3 | 1.2 | 399 |
4x35 | 7 | 1.6 | 24.7 | 0.868 | 547 |
4x50 | 7 | 1.6 | 27.3 | 0.641 | 699 |
4x70 | 12 | 1.8 | 32.4 | 0.443 | 990 |
4x95 | 19 | 1.8 | 36.8 | 0.32 | 1311 |
4x120 | 19 | 1.8 | 39.7 | 0.253 | 1597 |
No. of Cores and Section | No. of Wires | Nominal Insulation Thickness | Approx. Diameter | Max. DC. Resistance at 20ºC | Approx. Weight | |||
Phase | Neutral | Phase | Neutral | of Cable | Phase | Neutral | ||
mm2 | No. | No. | mm | mm | mm | Ω/km | Ω/km | kg/km |
1x25+1x54.6 | 7 | 7 | 1.4 | 1.6 | 21.3 | 1.2 | 0.63 | 309 |
1x35+1x54.6 | 7 | 7 | 1.6 | 1.6 | 22.7 | 0.868 | 0.63 | 345 |
1x50+1x54.6 | 7 | 7 | 1.6 | 1.6 | 23.8 | 0.641 | 0.63 | 384 |
1x70+1x54.6 | 12 | 7 | 1.8 | 1.6 | 25.9 | 0.443 | 0.63 | 456 |
1x95+1x54.6 | 19 | 7 | 1.8 | 1.6 | 27.7 | 0.32 | 0.63 | 537 |
1x70+1x70 | 12 | 7 | 1.8 | 1.6 | 26.7 | 0.443 | 0.5 | 491 |
1x95+1x70 | 19 | 7 | 1.8 | 1.6 | 28.5 | 0.32 | 0.5 | 571 |
1x120+1x70 | 19 | 7 | 1.8 | 1.6 | 29.7 | 0.253 | 0.5 | 643 |
1x120+1x95 | 19 | 19 | 1.8 | 1.6 | 31.9 | 0.253 | 0.343 | 737 |
1x150+1x95 | 19 | 19 | 1.8 | 1.6 | 33.6 | 0.206 | 0.343 | 819 |
3x25+1x54.6 | 7 | 7 | 1.4 | 1.6 | 23.5 | 1.2 | 0.63 | 508 |
3x35+1x54.6 | 7 | 7 | 1.6 | 1.6 | 26.1 | 0.868 | 0.63 | 619 |
3x50+1x54.6 | 7 | 7 | 1.6 | 1.6 | 28.1 | 0.641 | 0.63 | 733 |
3x70+1x54.6 | 12 | 7 | 1.8 | 1.6 | 31.9 | 0.443 | 0.63 | 951 |
3x95+1x54.6 | 19 | 7 | 1.8 | 1.6 | 35.2 | 0.32 | 0.63 | 1192 |
3x70+1x70 | 12 | 7 | 1.8 | 1.6 | 32.4 | 0.443 | 0.5 | 986 |
3x95+1x70 | 19 | 7 | 1.8 | 1.6 | 35.6 | 0.32 | 0.5 | 1227 |
3x120+1x70 | 19 | 7 | 1.8 | 1.6 | 37.8 | 0.253 | 0.5 | 1441 |
3x120+1x95 | 19 | 19 | 1.8 | 1.6 | 39.1 | 0.253 | 0.343 | 1536 |
3x150+1x95 | 19 | 19 | 1.8 | 1.6 | 42.2 | 0.206 | 0.343 | 1779 |
AAC/XLPE+AAAC/XLPE+AAC/XLPE
No. of Cores and Section | No. of Wires | Nominal Insulation Thickness | Approx. Diameter | Max. DC. Resistance at 20ºC | ||||||
Phase | Neutral | Street Light | Phase | Neutral | Street Light | of Cable | Phase | Neutral | Public lighting | |
mm2 | No. | No. | No. | mm | mm | mm | mm | Ω/km | Ω/km | Ω/km |
3x25+1x54.6+1x16 | 7 | 7 | 7 | 1.4 | 1.6 | 1.2 | 30.1 | 1.2 | 0.63 | 1.91 |
3x35+1x54.6+1x16 | 7 | 7 | 7 | 1.6 | 1.6 | 1.2 | 32.9 | 0.868 | 0.63 | 1.91 |
3x50+1x54.6+1x16 | 7 | 7 | 7 | 1.6 | 1.6 | 1.2 | 35.1 | 0.641 | 0.63 | 1.91 |
3x70+1x54.6+1x16 | 12 | 7 | 7 | 1.8 | 1.6 | 1.2 | 39.3 | 0.443 | 0.63 | 1.91 |
3x70+1x54.6+1x25 | 12 | 7 | 7 | 1.8 | 1.6 | 1.4 | 39.3 | 0.443 | 0.63 | 1.2 |
3x70+1x70+1x16 | 12 | 7 | 7 | 1.8 | 1.6 | 1.2 | 40.1 | 0.443 | 0.5 | 1.91 |
3x95+1x70+1x16 | 19 | 7 | 7 | 1.8 | 1.6 | 1.2 | 43.7 | 0.32 | 0.5 | 1.91 |
3x120+1x70+1x16 | 19 | 7 | 7 | 1.8 | 1.6 | 1.2 | 46.1 | 0.253 | 0.5 | 1.91 |
3x120+1x95+1x16 | 19 | 19 | 7 | 1.8 | 1.6 | 1.2 | 48.3 | 0.253 | 0.343 | 1.91 |
3x150+1x95+1x16 | 19 | 19 | 7 | 1.8 | 1.6 | 1.2 | 51.7 | 0.206 | 0.343 | 1.91 |
3x25+1x54.6+2x16 | 7 | 7 | 7 | 1.4 | 1.6 | 1.2 | 30.1 | 1.2 | 0.63 | 1.91 |
3x35+1x54.6+2x16 | 7 | 7 | 7 | 1.6 | 1.6 | 1.2 | 32.9 | 0.868 | 0.63 | 1.91 |
3x50+1x54.6+2x16 | 7 | 7 | 7 | 1.6 | 1.6 | 1.2 | 35.1 | 0.641 | 0.63 | 1.91 |
3x70+1x54.6+2x16 | 12 | 7 | 7 | 1.8 | 1.6 | 1.2 | 39.3 | 0.443 | 0.63 | 1.91 |
3x70+1x54.6+2x25 | 12 | 7 | 7 | 1.8 | 1.6 | 1.4 | 39.3 | 0.443 | 0.63 | 1.2 |
3x70+1x70+2x16 | 12 | 7 | 7 | 1.8 | 1.6 | 1.2 | 40.1 | 0.443 | 0.5 | 1.91 |
3x95+1x70+2x16 | 19 | 7 | 7 | 1.8 | 1.6 | 1.2 | 43.7 | 0.32 | 0.5 | 1.91 |
3x120+1x70+2x16 | 19 | 7 | 7 | 1.8 | 1.6 | 1.2 | 46.1 | 0.253 | 0.5 | 1.91 |
3x120+1x95+2x16 | 19 | 19 | 7 | 1.8 | 1.6 | 1.2 | 48.3 | 0.253 | 0.343 | 1.91 |
3x150+1x95+2x16 | 19 | 19 | 7 | 1.8 | 1.6 | 1.2 | 51.7 | 0.206 | 0.343 | 1.91 |