Product Details
Customization: Available
Customization: Available
Application: Construction, Overhead, Underground, Industrial
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 30 days
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
CCC
to see all verified strength labels (22)
  • Premium ACSR Bare Conductor with IEC61089 Compliance Standards
  • Premium ACSR Bare Conductor with IEC61089 Compliance Standards
  • Premium ACSR Bare Conductor with IEC61089 Compliance Standards
  • Premium ACSR Bare Conductor with IEC61089 Compliance Standards
  • Premium ACSR Bare Conductor with IEC61089 Compliance Standards
  • Premium ACSR Bare Conductor with IEC61089 Compliance Standards
Find Similar Products

Basic Info.

Model NO.
ACSR
Standard
IEC ASTM BS as Gbt
Voltage
Low and Medium Voltage Cable
Transport Package
Wooden Drum, Steel Drum, Steel&Wooden Drum, Pallet
Specification
A2/A3
Trademark
Xunda Cable
Origin
Henan
HS Code
7614900000
Production Capacity
3000 Tons/Month

Product Description

ACSR 

Premium ACSR Bare Conductor with IEC61089 Compliance Standards
DESCRIPTION
Aluminium Conductor Steel Reinforced (ACSR) is concentrically stranded conductor with one or more layers of hard drawn aluminium wire on galvanized steel wire core. The core can be single wire or stranded depending on the size. Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease.

APPLICATION
Used as bare overhead transmission conductor and as primary and secondary distribution conductor and messenger support. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
Premium ACSR Bare Conductor with IEC61089 Compliance Standards

Standards 
•IEC61089    • ASTM B 232    • BS EN 50182    • AS 3607    • GB/T 1179

IEC61089 (ACSR / A1/S1A)
Code Steel Ratio Areas No.of Wire Diameter Diameter Linear Mass Rated D.C.
Number Wires Strength Resistance
  Al Steel Total Al Steel Al Steel Core Cond.    
  % mm2 mm2 mm2     mm mm mm mm kg/km kN Ω/km
16 17 16 2.67 18.7 6 1 1 .84 1.84 1.84 5.53 64.6 6.08 1.7934
25 17 25 4.17 29.2 6 1 2.3 2.3 2.3 6.91 100.9 9.13 1.1478
40 17 40 6.67 46.7 6 1 2.91 2.91 2.91 8.74 161.5 14.4 0.7174
63 17 63 10.5 73.5 6 1 3.66 3.66 3.66 11 254.4 21.63 0.4555
100 17 100 16.7 117 6 1 4.61 4.61 4.61 13.8 403.8 34.33 0.2869
125 6 125 6.94 132 18 1 2.97 2.97 2.97 14.9 397.9 29.17 0.2304
125 16 125 20.4 145 26 7 2.47 1.92 5.77 15.7 503.9 45.69 0.231
160 6 160 8.89 169 18 1 3.36 3.36 3.36 16.8 509.3 36.18 0.18
160 16 160 26.1 186 26 7 2.8 2.18 6.53 17.7 644.9 57.69 0.1805
200 6 200 11.1 211 18 1 3.76 3.76 3.76 18.8 636.7 44.22 0.144
200 16 200 32.6 233 26 7 3.13 2.43 7.3 19.8 806.2 70.13 0.1444
250 10 250 24.6 275 22 7 3.8 2.11 6.34 21.6 880.6 68.72 0.1154
250 16 250 40.7 291 26 7 3.5 2.72 8.16 22.2 1007.7 87.67 0.1155
315 7 315 21.8 337 45 7 2.99 1.99 5.97 23.9 1039.6 79.03 0.0917
315 16 315 51.3 366 26 7 3.93 3.05 9.16 24.9 1269.7 106.83 0.0917
400 7 400 27.7 428 45 7 3.36 2.24 6.73 26.9 1320.1 98.36 0.0722
400 13 400 51.9 452 54 7 3.07 3.07 9.21 27.6 1510.3 123.04 0.0723
450 7 450 31.1 481 45 7 3.57 2.38 7.14 28.5 1485.2 107.47 0.0642
450 13 450 58.3 508 54 7 3.26 3.26 9.77 29.3 1699.1 138.42 0.0643
500 7 500 34.6 535 45 7 3.76 2.51 7.52 30.1 1650.2 119.41 0.0578
500 13 500 64.8 565 54 7 3.43 3.43 10.3 30.9 1887.9 153.8 0.0578
560 7 560 38.7 599 45 7 3.98 2.65 7.96 31.8 1848.2 133.74 0.0516
560 13 560 70.9 631 54 19 3.63 2.18 10.9 32.7 2103.4 172.59 0.0516
630 7 630 43.6 674 45 7 4.22 2.81 8.44 33.8 2079.2 150.45 0.0459
630 13 630 79.8 710 54 19 3.85 2.31 11.6 34.7 2366.3 191.77 0.0459
710 7 710 49.1 759 45 7 4.48 2.99 8.96 35.9 2343.2 169.56 0.0407
710 13 710 89.9 800 54 19 4.09 2.45 12.3 36.8 2666.8 216.12 0.0407
800 4 800 34.6 835 72 7 3.76 2.51 7.52 37.6 2480.2 167.41 0.0361
800 8 800 66.7 867 84 7 3.48 3.48 10.4 38.3 2732.7 205.33 0.0362
800 13 800 101 901 54 19 4.34 2.61 13 39.1 3004.9 243.52 0.0362
900 4 900 38.9 939 72 7 3.99 2.66 7.98 39.9 2790.2 188.33 0.0321
900 8 900 75 975 84 7 3.69 3.69 11.1 40.6 3074.2 226.5 0.0322
1000 4 1000 43.2 1043 72 7 4.21 2.8 8.41 42.1 3100.3 209.26 0.0289
1120 4 1120 47.3 1167 72 19 4.45 1.78 8.9 44.5 3464.9 234.53 0.0258
1120 8 1120 91.2 1211 84 19 4.12 2.47 12.4 45.3 3811.5 283.17 0.0258
1250 8 1250 102 1352 84 19 4.35 2.61 13.1 47.9 4253.9 316.04 0.0232
1250 4 1250 52.8 1303 72 19 4.7 1.88 9.4 47 3867.1 261.75 0.0231

IEC61089 (ACSR / A1/S2A)
Code Steel Ratio Areas No.of Wire Diameter Diameter Linear Mass Rated D.C.
Number Wires Strength Resistance
  Al Steel Total Al Steel Al Steel Core Cond.    
  % mm2 mm2 mm2     mm mm mm mm kg/km kN Ω/km
16 17 16 2.67 18.7 6 1 1.84 1.84 1.84 5.53 64.6 6.45 1.7934
25 17 25 4.17 29.2 6 1 2.3 2.3 2.3 6.91 100.9 9.71 1.1478
40 17 40 6.67 46.7 6 1 2.91 2.91 2.91 8.74 161.5 15.33 0.7174
63 17 63 10.5 73.5 6 1 3.66 3.66 3.66 11 254.4 22.37 0.4555
100 17 100 16.7 117 6 1 4.61 4.61 4.61 13.8 403.8 35.5 0.2869
125 6 125 6.94 132 18 1 2.97 2.97 2.97 14.9 397.9 30.14 0.2304
125 16 125 20.4 145 26 7 2.47 1.92 5.77 15.7 503.9 48.54 0.231
160 6 160 8.89 169 18 1 3.36 3.36 3.36 16.8 509.3 37.42 0.18
160 16 160 26.1 186 26 7 2.8 2.18 6.53 17.7 644.9 61.34 0.1805
200 6 200 11.1 211 18 1 3.76 3.76 3.76 18.8 636.7 45 0.144
200 16 200 32.6 233 26 7 3.13 2.43 7.3 19.8 806.2 74.69 0.1444
250 10 250 24.6 275 22 7 3.8 2.11 6.34 21.6 880.6 72.16 0.1154
250 16 250 40.7 291 26 7 3.5 2.72 8.16 22.2 1007.7 93.37 0.1155
315 7 315 21.8 337 45 7 2.99 1.99 5.97 23.9 1039.6 82.08 0.0917
315 16 315 51.3 366 26 7 3.93 3.05 9.16 24.9 1269.7 114.02 0.0917
400 7 400 27.7 428 45 7 3.36 2.24 6.73 26.9 1320.1 102.23 0.0722
400 13 400 51.9 452 54 7 3.07 3.07 9.21 27.6 1510.3 130.3 0.0723
450 7 450 31.1 481 45 7 3.57 2.38 7.14 28.5 1485.2 111.82 0.0642
450 13 450 58.3 508 54 7 3.26 3.26 9.77 29.3 1699.1 146.58 0.0643
500 7 500 34.6 535 45 7 3.76 2.51 7.52 30.1 1650.2 124.25 0.0578
500 13 500 64.8 565 54 7 3.43 3.43 10.3 30.9 1887.9 162.87 0.0578
560 7 560 38.7 599 45 7 3.98 2.65 7.96 31.8 1848.2 139.16 0.0516
560 13 560 70.9 631 54 19 3.63 2.18 10.9 32.7 2103.4 182.52 0.0516
630 7 630 43.6 674 45 7 4.22 2.81 8.44 33.8 2079.2 156.55 0.0459
630 13 630 79.8 710 54 19 3.85 2.31 11.6 34.7 2366.3 202.94 0.0459
710 7 710 49.1 759 45 7 4.48 2.99 8.96 35.9 2343.2 176.43 0.0407
710 13 710 89.9 800 54 19 4.09 2.45 12.3 36.8 2666.8 228.71 0.0407
800 4 800 34.6 835 72 7 3.76 2.51 7.52 37.6 2480.2 172.25 0.0361
800 8 800 66.7 867 84 7 3.48 3.48 10.4 38.3 2732.7 214.67 0.0362
800 13 800 101 901 54 19 4.34 2.61 13 39.1 3004.9 257.71 0.0362
900 4 900 38.9 939 72 7 3.99 2.66 7.98 39.9 2790.2 193.78 0.0321
900 8 900 75 975 84 7 3.69 3.69 11.1 40.6 3074.2 231.75 0.0322
1000 4 1000 43.2 1043 72 7 4.21 2.8 8.41 42.1 3100.3 215.31 0.0289
1120 4 1120 47.3 1167 72 19 4.45 1.78 8.9 44.5 3464.9 241.15 0.0258
1120 8 1120 91.2 1211 84 19 4.12 2.47 12.4 45.3 3811.5 295.94 0.0258
1250 4 1250 52.8 1303 72 19 4.7 1.88 9.4 47 3867.1 269.14 0.0231
1250 8 1250 102 1352 84 19 4.35 2.61 13.1 47.9 4253.9 330.29 0.0232

IEC61089 (ACSR / A1/S3A)
Code Steel Ratio Areas No.of Wire Diameter Diameter Linear Mass Rated D.C.
Number Wires Strength Resistance
  Al Steel Total Al Steel Al Steel Core Cond.    
  % mm2 mm2 mm2     mm mm mm mm kg/km kN Ω/km
16 17 16 2.67 18.7 6 1 1.84 1.84 1.84 5.53 64.6 6.83 1.7934
25 17 25 4.17 29.2 6 1 2.3 2.3 2.3 6.91 100.9 10.25 1.1478
40 17 40 6.67 46.7 6 1 2.91 2.91 2.91 8.74 161.5 16.2 0.7174
63 17 63 10.5 73.5 6 1 3.66 3.66 3.66 11 254.4 24.15 0.4555
100 17 100 16.7 117 6 1 4.61 4.61 4.61 13.8 403.8 38.33 0.2869
125 6 125 6.94 132 18 1 2.97 2.97 2.97 14.9 397.9 31.04 0.2304
125 16 125 20.4 145 26 7 2.47 1.92 5.77 15.7 503.9 51.39 0.231
160 6 160 8.89 169 18 1 3.36 3.36 3.36 16.8 509.3 38.67 0.18
160 16 160 26.1 186 26 7 2.8 2.18 6.53 17.7 644.9 64.99 0.1805
200 6 200 11.l 211 18 1 3.76 3.76 3.76 18.8 636.7 46.89 0.144
200 16 200 32.6 233 26 7 3.13 2.43 7.3 19.8 806.2 78.93 0.1444
250 10 250 24.6 275 22 7 3.8 2.11 6.34 21.6 880.6 75.6 0.1154
250 16 250 40.7 291 26 7 3.5 2.72 8.16 22.2 1007.7 98.66 0.1155
315 7 315 21.8 337 45 7 2.99 1.99 5.97 23.9 1039.6 85.13 0.0917
315 16 315 51.3 366 26 7 3.93 3.05 9.16 24.9 1269.7 121.2 0.0917
400 7 400 27.7 428 45 7 3.36 2.24 6.73 26.9 1320.1 106.1 0.0722
400 13 400 51.9 452 54 7 3.07 3.07 9.21 27.6 1510.3 137.56 0.0723
450 7 450 31.1 481 45 7 3.57 2.38 7.14 28.5 1485.2 115.87 0.0642
450 13 450 58.3 508 54 7 3.26 3.26 9.77 29.3 1699.1 154.75 0.0643
500 7 500 34.6 535 45 7 3.76 2.51 7.52 30.1 1650.2 128.74 0.0578
500 13 500 64.8 565 54 7 3.43 3.43 10.3 30.9 1887.9 171.94 0.0578
560 7 560 38.7 599 45 7 3.98 2.65 7.96 31.8 1848.2 144.19 0.0516
560 13 560 70.9 631 54 19 3.63 2.18 10.9 32.7 2103.4 192.45 0.0516
630 7 630 43.6 674 45 7 4.22 2.81 8.44 33.8 2079.2 162.21 0.0459
630 13 630 79.8 710 54 19 3.85 2.31 11.6 34.7 2366.3 213.32 0.0459
710 7 710 49.1 759 45 7 4.48 2.99 8.96 35.9 2343.2 182.81 0.0407
710 13 710 89.9 800 54 19 4.09 2.45 12.3 36.8 2666.8 240.41 0.0407
800 4 800 34.6 835 72 7 3.76 2.51 7.52 37.6 2480.2 176.74 0.0361
800 8 800 66.7 867 84 7 3.48 3.48 10.4 38.3 2732.7 224 0.0362
800 13 800 101 901 54 19 4.34 2.61 13 39.1 3004.9 270.88 0.0362
900 4 900 38.9 939 72 7 3.99 2.66 7.98 39.9 2790.2 198.83 0.0321
900 8 900 75 975 84 7 3.69 3.69 11.1 40.6 3074.2 244.5 0.0322
1000 4 1000 43.2 1043 72 7 4.21 2.8 8.41 42.1 3100.3 220.93 0.0289
1120 4 1120 47.3 1167 72 19 4.48 1.78 8.9 44.5 3464.9 247.77 0.0258
1120 8 1120 91.2 1211 84 19 4.12 2.47 12.4 45.3 3811.5 307.79 0.0258
1250 4 1250 52.8 1303 72 19 4.7 1.88 9.4 47 3867.1 276.53 0.0231
1250 8 1250 102 1352 84 19 4.35 2.61 13.1 47.9 4253.9 343.52 0.0232

Premium ACSR Bare Conductor with IEC61089 Compliance Standards
Industry Solutions
Power grid
New energy
Building
Industry
Marine cable
Telecommunication
Railway
Instrument


Our Certificate
Premium ACSR Bare Conductor with IEC61089 Compliance Standards
Company Information


Premium ACSR Bare Conductor with IEC61089 Compliance StandardsPremium ACSR Bare Conductor with IEC61089 Compliance StandardsPremium ACSR Bare Conductor with IEC61089 Compliance StandardsPremium ACSR Bare Conductor with IEC61089 Compliance Standards
FAQ

1. Q:Are you a factory or trading company?
A: Manufacturing base in Henan ,China, with more than 150 workers.

2. Q:How can I visit there?
A: Sure,lf you need,we will arrange the driver to pick you up.

3. Q:How can I get some samples?
A: Contact me on below,Determine sample and address for shipping.

4. Q:Have you ever supplied cables to our country?
A: Xunda Cable have been sold to over 30 countries and regions in the world. you cancontact me for details.

5. Q:What is your MOQ?
A: MOQ Normally 1km for insulated cables(1 ton for bare conductor).Please contact mefor detail info if you have specific cable requirement.

6. Q:When can l get the price?
A: Usually quote within 3hours after we get your inquiry.

7. Q:How long is your delivery time?
A: According to your order's quantity.Usually our lead time is 3 - 20 working days.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier