Customization: | Available |
---|---|
Type: | Insulated |
Conductor Type: | Stranded |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ABC-aerial bundled cables
Code Word | Phase Conductor | Bare Neutral Messenger | Approx. Diameter of Cable | Approx. Weight | ||||
Size | No.of wires | Nominal Insulation Thickness | Size | No.of Wires | Diameter of Wires | |||
AWG or Kcmil | No. | mm | AWG or Kcmil | No. | mm | mm | kg/km | |
AAC/XLPE+AAC | ||||||||
Pekingese | 6 | 1 | 1.14 | 6 | 7 | 1.56 | 11.1 | 92 |
Collie | 6 | 7 | 1.14 | 6 | 7 | 1.56 | 11.5 | 94 |
Cocker | 6 | 7 | 1.52 | 6 | 7 | 1.56 | 12.2 | 100 |
Dachshund | 4 | 1 | 1.14 | 4 | 7 | 1.96 | 13.4 | 140 |
Spaniel | 4 | 7 | 1.14 | 4 | 7 | 1.96 | 13.9 | 143 |
Cairn | 4 | 7 | 1.52 | 4 | 7 | 1.96 | 14.6 | 150 |
Doberman | 2 | 7 | 1.14 | 2 | 7 | 2.47 | 16.9 | 220 |
Airedale | 1 | 19 | 1.52 | 1 | 7 | 2.78 | 19.6 | 280 |
Basset | 1/0 | 7 | 1.52 | 1/0 | 7 | 3.12 | 21.8 | 355 |
Malemute | 1/0 | 19 | 1.52 | 1/0 | 7 | 3.12 | 21.6 | 350 |
AAC/XLPE+AAAC | ||||||||
Chihuahua | 6 | 1 | 1.14 | 30.58 | 7 | 1.68 | 11.4 | 98 |
Vizsla | 6 | 7 | 1.14 | 30.58 | 7 | 1.68 | 11.8 | 100 |
Harrier | 4 | 1 | 1.14 | 48.69 | 7 | 2.12 | 13.8 | 149 |
Whippet | 4 | 7 | 1.14 | 48.69 | 7 | 2.12 | 14.4 | 154 |
Schnauzer | 2 | 7 | 1.14 | 77.47 | 7 | 2.67 | 17.5 | 235 |
Afghan | 1/0 | 7 | 1.52 | 123.3 | 7 | 3.37 | 22.5 | 378 |
Heeler | 1/0 | 19 | 1.52 | 123.3 | 7 | 3.37 | 22.3 | 375 |
AAC/XLPE+ACSR | ||||||||
Setter | 6 | 1 | 1.14 | 6 | 6/1 | 1.68 | 11.4 | 109 |
Shepherd | 6 | 7 | 1.14 | 6 | 6/1 | 1.68 | 11.8 | 112 |
Retriever | 6 | 7 | 1.52 | 6 | 6/1 | 1.68 | 12.6 | 119 |
Eskimo | 4 | 1 | 1.14 | 4 | 6/1 | 2.12 | 13.8 | 166 |
Terrier | 4 | 7 | 1.14 | 4 | 6/1 | 2.12 | 14.4 | 170 |
Yorkshire | 4 | 7 | 1.52 | 4 | 6/1 | 2.12 | 15.1 | 180 |
Chow | 2 | 7 | 1.14 | 2 | 6/1 | 2.67 | 17.5 | 262 |
Labrador | 1 | 19 | 1.52 | 1 | 6/1 | 3 | 20.2 | 339 |
Bloodhound | 1/0 | 7 | 1.52 | 1/0 | 6/1 | 3.37 | 22.5 | 425 |
Bull | 1/0 | 19 | 1.52 | 1/0 | 6/1 | 3.37 | 22.3 | 422 |
Triplex Service Drop - Aluminum Conductors
Code Word | Phase Conductor | Bare Neutral Messenger | Approx. Diameter of Cable | Approx. Weight | ||||
Size | No.of Wires | Nominal Insulation Thickness | Size | No.of Wires | Diameter of Wires | |||
AWG or Kcmil | No. | mm | AWG or Kcmil | No. | mm | mm | kg/km | |
AAC/XLPE+AAC | ||||||||
Haiotis | 6 | 1 | 1.14 | 6 | 7 | 1.56 | 12.6 | 148 |
Pike | 6 | 7 | 0.76 | 6 | 7 | 1.56 | 12.1 | 139 |
Patella | 6 | 7 | 1.14 | 6 | 7 | 1.56 | 13.2 | 154 |
Albus | 6 | 7 | 1.52 | 6 | 7 | 1.56 | 14.3 | 170 |
Fusus | 4 | 1 | 1.14 | 4 | 7 | 1.96 | 15 | 221 |
Limpet | 4 | 7 | 1.14 | 6 | 7 | 1.56 | 14.9 | 208 |
Oyster | 4 | 7 | 1.14 | 4 | 7 | 1.96 | 15.8 | 230 |
Argo | 4 | 7 | 1.52 | 4 | 7 | 1.96 | 16.9 | 249 |
Clam | 2 | 7 | 1.14 | 2 | 7 | 2.47 | 19 | 347 |
Thia | 2 | 7 | 1.52 | 2 | 7 | 2.47 | 20.1 | 370 |
Mussel | 2 | 7 | 1.14 | 4 | 7 | 1.96 | 17.9 | 312 |
Pyrula | 1 | 7 | 1.52 | 1 | 7 | 2.78 | 22.4 | 465 |
Hyas | 1 | 19 | 1.52 | 1 | 7 | 2.78 | 22.2 | 450 |
Snail | 1/0 | 7 | 1.52 | 2 | 7 | 2.47 | 23.2 | 517 |
Murex | 1/0 | 7 | 1.52 | 1/0 | 7 | 3.12 | 24.6 | 572 |
Purpura | 1/0 | 19 | 1.52 | 1/0 | 7 | 3.12 | 24.4 | 554 |
Nassa | 2/0 | 7 | 1.52 | 2/0 | 7 | 3.5 | 27.1 | 706 |
Trophon | 2/0 | 19 | 1.52 | 2/0 | 7 | 3.5 | 26.8 | 684 |
Quahog | 3/0 | 7 | 2.03 | 3/0 | 7 | 3.93 | 31.3 | 920 |
Ione | 3/0 | 19 | 2.03 | 3/0 | 7 | 3.93 | 31 | 892 |
Melita | 3/0 | 19 | 1.52 | 3/0 | 19 | 2.39 | 29.7 | 845 |
Coquina | 4/0 | 7 | 1.52 | 4/0 | 7 | 4.42 | 33 | 1082 |
Tusk | 4/0 | 7 | 2.03 | 4/0 | 7 | 4.42 | 34.5 | 1134 |
Apus | 4/0 | 19 | 2.03 | 4/0 | 7 | 4.42 | 34.1 | 1098 |
Portunus | 4/0 | 19 | 2.03 | 4/0 | 19 | 2.68 | 34.2 | 1098 |
Chiton | 266.8 | 19 | 2.03 | 266.8 | 19 | 3.01 | 38.4 | 1379 |
Alverno | 300 | 37 | 2.03 | 4/0 | 19 | 2.68 | 37.8 | 1386 |
Nannynose | 336.4 | 19 | 2.03 | 336.4 | 19 | 3.38 | 42.4 | 1707 |
AAC/XLPE+AAAC | ||||||||
Minex | 6 | 1 | 1.14 | 30.58 | 7 | 1.68 | 12.8 | 154 |
Hippa | 6 | 7 | 1.14 | 30.58 | 7 | 1.68 | 13.4 | 160 |
Code Word | Phase Conductor | Bare Neutral Messenger | Approx. Diameter of Cable | Approx. Weight | ||||
Size | No.of Wires | NominalInsulation Thickness | Size | No.of Wires | Diameter of Wires | |||
AWG or Kcmil | No. | mm | AWG or Kcmil | No. | mm | mm | kg/km | |
AAC/XLPE+AAAC | ||||||||
Artemia | 4 | 1 | 1.14 | 30.58 | 7 | 1.68 | 14.4 | 205 |
Crad | 4 | 7 | 1.14 | 30.58 | 7 | 1.68 | 15.2 | 214 |
Prawn | 4 | 1 | 1.14 | 48.69 | 7 | 2.12 | 15.3 | 231 |
Barnacle | 4 | 7 | 1.14 | 48.69 | 7 | 2.12 | 16.1 | 239 |
Solaster | 2 | 7 | 1.14 | 48.69 | 7 | 2.12 | 18.2 | 322 |
Pagurus | 2 | 7 | 1.52 | 48.69 | 7 | 2.12 | 19.3 | 345 |
Shrimp | 2 | 7 | 1.14 | 77.47 | 7 | 2.67 | 19.4 | 362 |
Lobster | 2 | 7 | 1.52 | 77.47 | 7 | 2.67 | 20.5 | 385 |
Sanderab | 1/0 | 7 | 1.52 | 77.47 | 7 | 2.67 | 23.6 | 532 |
Echinus | 1/0 | 19 | 1.52 | 77.47 | 7 | 2.67 | 23.4 | 514 |
Gammarus | 1/0 | 7 | 1.52 | 123.3 | 7 | 3.37 | 25.1 | 597 |
Leda | 1/0 | 19 | 1.52 | 123.3 | 7 | 3.37 | 24.9 | 579 |
Crayfish | 2/0 | 7 | 1.52 | 97.65 | 7 | 3 | 26 | 655 |
Sipho | 2/0 | 19 | 1.52 | 97.65 | 7 | 3 | 25.7 | 633 |
Abalone | 2/0 | 7 | 1.52 | 123.3 | 7 | 3.37 | 26.8 | 691 |
Spirula | 2/0 | 19 | 1.52 | 123.3 | 7 | 3.37 | 26.5 | 669 |
Dungenese | 2/0 | 7 | 1.52 | 155.4 | 7 | 3.78 | 27.7 | 736 |
Cyclops | 2/0 | 19 | 1.52 | 155.4 | 7 | 3.78 | 27.4 | 714 |
Slug | 3/0 | 7 | 1.52 | 123.3 | 7 | 3.37 | 28.6 | 809 |
Fulgur | 3/0 | 19 | 1.52 | 123.3 | 7 | 3.37 | 28.4 | 781 |
Balanus | 3/0 | 19 | 2.03 | 123.3 | 7 | 3.37 | 29.8 | 828 |
Stonecrab | 3/0 | 7 | 1.52 | 195.7 | 7 | 4.25 | 30.5 | 904 |
Flustra | 3/0 | 19 | 1.52 | 195.7 | 7 | 4.25 | 30.3 | 884 |
Crisia | 3/0 | 19 | 2.03 | 195.7 | 7 | 4.25 | 31.7 | 931 |
Squid | 4/0 | 7 | 1.52 | 155.4 | 7 | 3.78 | 31.6 | 1001 |
Arca | 4/0 | 19 | 1.52 | 155.4 | 7 | 3.78 | 31.3 | 966 |
Bugula | 4/0 | 19 | 2.03 | 155.4 | 7 | 3.78 | 32.7 | 1018 |
Kingcrab | 4/0 | 7 | 1.52 | 246.9 | 7 | 4.77 | 33.8 | 1131 |
Lepas | 4/0 | 19 | 1.52 | 246.9 | 7 | 4.77 | 33.4 | 1096 |
Cassis | 4/0 | 19 | 2.03 | 246.9 | 7 | 4.77 | 34.9 | 1147 |
Cyphoma | 4/0 | 7 | 1.52 | 123.3 | 7 | 3.37 | 30.8 | 957 |
Mitre | 4/0 | 19 | 1.52 | 123.3 | 7 | 3.37 | 30.4 | 921 |
Argonaut | 336.4 | 19 | 2.03 | 246.9 | 7 | 4.77 | 40.5 | 1579 |
Nautilis | 336.4 | 19 | 2.03 | 394.5 | 19 | 3.66 | 43.4 | 1787 |
Code Word | Phase Conductor | Bare Neutral Messenger | Approx. Diameter of Cable | Approx. Weight | ||||
Size | No.of Wires | NominalInsulation Thickness | Size | No.of wires | Diameter of Wires | |||
AWG or Kcmil | No. | mm | AWG or Kcmil | No. | mm | mm | kg/km | |
AAC/XLPE+ACSR | ||||||||
Paludina | 6 | 1 | 1.14 | 6 | 6/1 | 1.68 | 12.8 | 165 |
Voluta | 6 | 7 | 1.14 | 6 | 6/1 | 1.68 | 13.4 | 171 |
Bolma | 6 | 7 | 1.52 | 6 | 6/1 | 1.68 | 14.5 | 188 |
Scallop | 4 | 1 | 1.14 | 6 | 6/1 | 1.68 | 14.4 | 217 |
Strombus | 4 | 7 | 1.14 | 6 | 6/1 | 1.68 | 15.1 | 225 |
Carnea | 4 | 7 | 1.52 | 6 | 6/1 | 1.68 | 16.2 | 244 |
Whelk | 4 | 1 | 1.14 | 4 | 6/1 | 2.12 | 15.3 | 249 |
Periwinkle | 4 | 7 | 1.14 | 4 | 6/1 | 2.12 | 16.1 | 257 |
Calma | 4 | 7 | 1.52 | 4 | 6/1 | 2.12 | 17.2 | 277 |
Cockle | 2 | 7 | 1.14 | 4 | 6/1 | 2.12 | 18.2 | 340 |
Gebia | 2 | 7 | 1.52 | 4 | 6/1 | 2.12 | 19.3 | 363 |
Conch | 2 | 7 | 1.14 | 2 | 6/1 | 2.67 | 19.4 | 391 |
Uca | 2 | 7 | 1.52 | 2 | 6/1 | 2.67 | 20.5 | 414 |
Vermeths | 1 | 7 | 1.52 | 1 | 6/1 | 3 | 22.9 | 520 |
Atya | 1 | 19 | 1.52 | 1 | 6/1 | 3 | 22.6 | 506 |
Janthina | 1/0 | 7 | 1.52 | 2 | 6/1 | 2.67 | 23.6 | 561 |
Ranella | 1/0 | 19 | 1.52 | 2 | 6/1 | 2.67 | 23.4 | 543 |
Neritina | 1/0 | 7 | 1.52 | 1/0 | 6/1 | 3.37 | 25.1 | 642 |
Cenia | 1/0 | 19 | 1.52 | 1/0 | 6/1 | 3.37 | 24.9 | 624 |
Cavolinia | 2/0 | 7 | 1.52 | 1 | 6/1 | 3 | 26 | 691 |
Clio | 2/0 | 19 | 1.52 | 1 | 6/1 | 3 | 25.7 | 669 |
Runcina | 2/0 | 7 | 1.52 | 2/0 | 6/1 | 3.78 | 27.7 | 794 |
Triton | 2/0 | 19 | 1.52 | 2/0 | 6/1 | 3.78 | 27.4 | 772 |
Sanddollar | 3/0 | 7 | 1.52 | 1/0 | 6/1 | 3.37 | 28.6 | 854 |
Aega | 3/0 | 19 | 1.52 | 1/0 | 6/1 | 3.37 | 28.4 | 827 |
Pisa | 3/0 | 19 | 2.03 | 1/0 | 6/1 | 3.37 | 29.8 | 874 |
Cherrystone | 3/0 | 7 | 1.52 | 3/0 | 6/1 | 4.25 | 30.5 | 983 |
Mursia | 3/0 | 19 | 1.52 | 3/0 | 6/1 | 4.25 | 30.3 | 956 |
Mysis | 3/0 | 19 | 2.03 | 3/0 | 6/1 | 4.25 | 31.7 | 1003 |
Cuttlefish | 4/0 | 7 | 1.52 | 2/0 | 6/1 | 3.78 | 31.7 | 1059 |
Code Word | Phase Conductor | Bare Neutral Messenger | Approx. Diameter of Cable | Approx. Weight | ||||
Size | No.of Wires | NominalInsulation Thickness | Size | No.of wires | Diameter of Wires | |||
AWG or Kcmil | No. | mm | AWG or Kcmil | No. | mm | mm | kg/km | |
AAC/XLPE+ACSR | ||||||||
Cerapus | 4/0 | 19 | 1.52 | 2/0 | 6/1 | 3.78 | 31.3 | 1024 |
Nepatus | 4/0 | 19 | 2.03 | 2/0 | 6/1 | 3.78 | 32.7 | 1075 |
Razor | 4/0 | 7 | 1.52 | 4/0 | 6/1 | 4.77 | 33.8 | 1222 |
Zuzara | 4/0 | 19 | 1.52 | 4/0 | 6/1 | 4.77 | 33.4 | 1187 |
Alima | 4/0 | 19 | 2.03 | 4/0 | 6/1 | 4.77 | 34.9 | 1238 |
Callista | 266.8 | 19 | 2.03 | 3/0 | 6/1 | 4.25 | 36.7 | 1350 |
Dosinia | 266.8 | 19 | 2.03 | 266.8 | 18/1 | 3.09 | 38.7 | 1438 |
Cowry | 336.4 | 19 | 2.03 | 4/0 | 6/1 | 4.77 | 40.5 | 1670 |
Limpet | 336.4 | 19 | 2.03 | 336.4 | 18/1 | 3.47 | 42.7 | 1782 |
Quadruplex Service Drop - Aluminum Conductors
Code Word | Phase Conductor | Bare Neutral Messenger | Approx. Diameter of Cable | Approx. Weight | ||||
Size | No.of Wires | Nominal Insulation Thickness | Size | No.of wires | Diameter of Wires | |||
AWG or Kcmil | No. | mm | AWG or Kcmil | No. | mm | mm | kg/km | |
AAC/XLPE+AAC | ||||||||
Quarter | 6 | 1 | 1.14 | 6 | 7 | 1.56 | 14.4 | 203 |
Clydesdate | 4 | 1 | 1.14 | 4 | 7 | 1.96 | 17.1 | 302 |
Pinto | 4 | 7 | 1.14 | 4 | 7 | 1.96 | 18.1 | 315 |
Mustang | 2 | 7 | 1.14 | 2 | 7 | 2.47 | 21.7 | 474 |
Shire | 1 | 19 | 1.52 | 1 | 7 | 2.78 | 25.4 | 616 |
Libyan | 1/0 | 7 | 1.52 | 1/0 | 7 | 3.12 | 28.2 | 784 |
Criollo | 1/0 | 19 | 1.52 | 1/0 | 7 | 3.12 | 27.9 | 757 |
Orloff | 2/0 | 7 | 1.52 | 2/0 | 7 | 3.5 | 30.9 | 965 |
Percheron | 2/0 | 19 | 1.52 | 2/0 | 7 | 3.5 | 30.6 | 931 |
Mongolian | 3/0 | 7 | 1.52 | 3/0 | 7 | 3.93 | 34.1 | 1190 |
Hanoverian | 3/0 | 19 | 1.52 | 3/0 | 19 | 2.39 | 33.8 | 1148 |
Singlefoot | 4/0 | 7 | 1.52 | 4/0 | 7 | 4.42 | 37.6 | 1474 |
Oldenburg | 4/0 | 19 | 1.52 | 4/0 | 19 | 2.68 | 37.2 | 1421 |
Lippizaner | 336.4 | 19 | 2.03 | 336.4 | 19 | 3.38 | 48.3 | 2322 |
AAC/XLPE+AAAC | ||||||||
Bay | 6 | 1 | 1.14 | 30.58 | 7 | 1.68 | 14.7 | 209 |
French-Coach | 6 | 7 | 1.14 | 30.58 | 7 | 1.68 | 15.4 | 218 |
German-Coach | 4 | 1 | 1.14 | 48.69 | 7 | 2.12 | 17.4 | 312 |
Arabian | 4 | 7 | 1.14 | 48.69 | 7 | 2.12 | 18.4 | 324 |
Belgian | 2 | 7 | 1.14 | 77.47 | 7 | 2.67 | 22 | 489 |
Viatka | 1/0 | 7 | 1.52 | 77.47 | 7 | 2.67 | 27.4 | 743 |
Thoroughbred | 2/0 | 19 | 1.52 | 155.4 | 7 | 3.78 | 31.1 | 962 |
Celtic | 2/0 | 7 | 1.52 | 123.3 | 7 | 3.37 | 30.7 | 950 |
Norman | 2/0 | 19 | 1.52 | 123.3 | 7 | 3.37 | 30.3 | 917 |
Donkey | 3/0 | 7 | 1.52 | 123.3 | 7 | 3.37 | 33 | 1126 |
Burro | 3/0 | 19 | 1.52 | 123.3 | 7 | 3.37 | 32.7 | 1085 |
Dobbin | 3/0 | 7 | 1.52 | 195.7 | 7 | 4.25 | 34.6 | 1229 |
Trotter | 3/0 | 19 | 1.52 | 195.7 | 7 | 4.25 | 34.3 | 1188 |
Roan | 4/0 | 7 | 1.52 | 123.3 | 7 | 3.37 | 35.7 | 1348 |
Gotland | 4/0 | 19 | 1.52 | 123.3 | 7 | 3.37 | 35.2 | 1295 |
Bali | 4/0 | 7 | 1.52 | 155.4 | 7 | 3.78 | 36.5 | 1393 |
Skyros | 4/0 | 19 | 1.52 | 155.4 | 7 | 3.78 | 36 | 1340 |
P ony | 4/0 | 7 | 1.52 | 246.9 | 7 | 4.77 | 38.3 | 1522 |
Code Word | Phase Conductor | Bare Neutral Messenger | Approx. Diameter of Cable | Approx. Weight | ||||
Size | No.of Wires | NominalInsulation Thickness | Size | No.of Wires | Diameter of Wires | |||
AWG or Kcmil | No. | mm | AWG or Kcmil | No. | mm | mm | kg/km | |
AAC/XLPE+AAAC | ||||||||
Walking | 4/0 | 19 | 1.52 | 246.9 | 7 | 4.77 | 37.8 | 1470 |
Exmoor | 336.4 | 19 | 2.03 | 246.9 | 19 | 2.89 | 46.8 | 2193 |
Breton | 336.4 | 19 | 2.03 | 394.5 | 19 | 3.66 | 49.1 | 2402 |
AAC/XLPE+ACSR | ||||||||
Morochuca | 6 | 1 | 1.14 | 6 | 6/1 | 1.68 | 14.7 | 221 |
Chola | 6 | 7 | 1.14 | 6 | 6/1 | 1.68 | 15.4 | 229 |
Morgan | 4 | 1 | 1.14 | 4 | 6/1 | 2.12 | 17.4 | 330 |
Hackney | 4 | 7 | 1.14 | 4 | 6/1 | 2.12 | 18.4 | 342 |
Palomino | 2 | 7 | 1.14 | 2 | 6/1 | 2.67 | 22 | 518 |
Albino | 1 | 19 | 1.52 | 1 | 6/1 | 3 | 25.8 | 672 |
Standardbred | 1/0 | 7 | 1.52 | 1/0 | 6/1 | 3.37 | 28.6 | 854 |
Costena | 1/0 | 19 | 1.52 | 1/0 | 6/1 | 3.37 | 28.3 | 827 |
Chicoteagues | 2/0 | 7 | 1.52 | 2/0 | 6/1 | 3.78 | 31.5 | 1053 |
Grullo | 2/0 | 19 | 1.52 | 2/0 | 6/1 | 3.78 | 31.1 | 1022 |
Mare | 3/0 | 7 | 1.52 | 3/0 | 6/1 | 4.25 | 34.6 | 1301 |
Suffolk | 3/0 | 19 | 1.52 | 3/0 | 6/1 | 4.25 | 34.3 | 1260 |
Stallion | 4/0 | 7 | 1.52 | 4/0 | 6/1 | 4.77 | 38.3 | 1614 |
Appaloosa | 4/0 | 19 | 1.52 | 4/0 | 6/1 | 4.77 | 37.8 | 1561 |
Gelding | 336.4 | 19 | 2.03 | 4/0 | 6/1 | 4.77 | 46.7 | 2285 |
Bronco | 336.4 | 19 | 2.03 | 336.4 | 18/1 | 3.47 | 48.6 | 2396 |
NFC 33-209
Designation | Average Thickness of Insulation (prescribed value) | Core | |||||||
Nature | Nominal Section | No. of Wires | Max. DC Resistance at 20 0C | Conductor | Breaking Force | Outside Diameter | |||
Diameter | |||||||||
(mm2) | No. | (Ω/km) | Min. (mm) | Max. (mm) | Min. (daN) | (mm) | Min. (mm) | Max. (mm) | |
Phase or neutral or public lighting | 16 | 7 | 1.91 | 4.6 | 5.1 | 190 | 1.2 | 7 | 7.8 |
25 | 7 | 1.2 | 5.8 | 6.3 | 300 | 1.4 | 8.6 | 9.4 | |
35 | 7 | 0.868 | 6.8 | 7.3 | -- | 1.6 | 10 | 10.9 | |
50 | 7 | 0.641 | 7.9 | 8.4 | -- | 1.6 | 11.1 | 12 | |
70 | 12 | 0.443 | 9.7 | 10.2 | -- | 1.8 | 13.3 | 14.2 | |
95 | 19 | 0.32 | 11 | 12 | -- | 1.8 | 14.6 | 15.7 | |
120 | 19 | 0.253 | 12 | 13.1 | -- | 1.8 | 15.6 | 16.7 | |
150 | 19 | 0.206 | 13.9 | 15 | -- | 1.8 | 17.3 | 18.6 | |
Neutral | 54.6 | 7 | 0.63 | 9.2 | 9.6 | 1660 | 1.6 | 12.3 | 13 |
70 | 7 | 0.5 | 10 | 10.2 | 2050 | 1.6 | 12.9 | 13.6 | |
95 | 19 | 0.343 | 12.2 | 12.9 | 2750 | 1.6 | 15.3 | 16.3 | |
Pilot | 1.5 | 1 | 12.1 | -- | 1.5 | -- | 1.2 | 3.7 | 4.2 |
AAC/XLPE
No. of Cores and Section | No. of Wires | Nominal Insulation Thickness | Approx. Diameter | Max. DC. Resistance at 20ºC | Approx. Weight |
of Cable | |||||
mm2 | No. | mm | mm | Ω/km | kg/km |
2x16 | 7 | 1.2 | 14.4 | 1.91 | 131 |
2x25 | 7 | 1.4 | 17.6 | 1.2 | 200 |
2x35 | 7 | 1.6 | 20.4 | 0.868 | 273 |
2x50 | 7 | 1.6 | 22.6 | 0.641 | 350 |
2x70 | 12 | 1.8 | 26.8 | 0.443 | 495 |
2x95 | 19 | 1.8 | 30.4 | 0.32 | 656 |
2x120 | 19 | 1.8 | 32.8 | 0.253 | 799 |
4x16 | 7 | 1.2 | 17.4 | 1.91 | 262 |
4x25 | 7 | 1.4 | 21.3 | 1.2 | 399 |
4x35 | 7 | 1.6 | 24.7 | 0.868 | 547 |
4x50 | 7 | 1.6 | 27.3 | 0.641 | 699 |
4x70 | 12 | 1.8 | 32.4 | 0.443 | 990 |
4x95 | 19 | 1.8 | 36.8 | 0.32 | 1311 |
4x120 | 19 | 1.8 | 39.7 | 0.253 | 1597 |
AAC/XLPE+AAAC/XLPE
No. of Cores and Section | No. of Wires | Nominal Insulation Thickness | Approx. Diameter | Max. DC. Resistance at 20ºC | Approx. Weight | |||
Phase | Neutral | Phase | Neutral | of Cable | Phase | Neutral | ||
mm2 | No. | No. | mm | mm | mm | Ω/km | Ω/km | kg/km |
1x25+1x54.6 | 7 | 7 | 1.4 | 1.6 | 21.3 | 1.2 | 0.63 | 309 |
1x35+1x54.6 | 7 | 7 | 1.6 | 1.6 | 22.7 | 0.868 | 0.63 | 345 |
1x50+1x54.6 | 7 | 7 | 1.6 | 1.6 | 23.8 | 0.641 | 0.63 | 384 |
1x70+1x54.6 | 12 | 7 | 1.8 | 1.6 | 25.9 | 0.443 | 0.63 | 456 |
1x95+1x54.6 | 19 | 7 | 1.8 | 1.6 | 27.7 | 0.32 | 0.63 | 537 |
1x70+1x70 | 12 | 7 | 1.8 | 1.6 | 26.7 | 0.443 | 0.5 | 491 |
1x95+1x70 | 19 | 7 | 1.8 | 1.6 | 28.5 | 0.32 | 0.5 | 571 |
1x120+1x70 | 19 | 7 | 1.8 | 1.6 | 29.7 | 0.253 | 0.5 | 643 |
1x120+1x95 | 19 | 19 | 1.8 | 1.6 | 31.9 | 0.253 | 0.343 | 737 |
1x150+1x95 | 19 | 19 | 1.8 | 1.6 | 33.6 | 0.206 | 0.343 | 819 |
3x25+1x54.6 | 7 | 7 | 1.4 | 1.6 | 23.5 | 1.2 | 0.63 | 508 |
3x35+1x54.6 | 7 | 7 | 1.6 | 1.6 | 26.1 | 0.868 | 0.63 | 619 |
3x50+1x54.6 | 7 | 7 | 1.6 | 1.6 | 28.1 | 0.641 | 0.63 | 733 |
3x70+1x54.6 | 12 | 7 | 1.8 | 1.6 | 31.9 | 0.443 | 0.63 | 951 |
3x95+1x54.6 | 19 | 7 | 1.8 | 1.6 | 35.2 | 0.32 | 0.63 | 1192 |
3x70+1x70 | 12 | 7 | 1.8 | 1.6 | 32.4 | 0.443 | 0.5 | 986 |
3x95+1x70 | 19 | 7 | 1.8 | 1.6 | 35.6 | 0.32 | 0.5 | 1227 |
3x120+1x70 | 19 | 7 | 1.8 | 1.6 | 37.8 | 0.253 | 0.5 | 1441 |
3x120+1x95 | 19 | 19 | 1.8 | 1.6 | 39.1 | 0.253 | 0.343 | 1536 |
3x150+1x95 | 19 | 19 | 1.8 | 1.6 | 42.2 | 0.206 | 0.343 | 1779 |
AAC/XLPE+AAAC/XLPE+AAC/XLPE
No. of Cores and Section | No. of Wires | Nominal Insulation Thickness | Approx. Diameter | Max. DC. Resistance at 20ºC | ||||||
Phase | Neutral | Street Light | Phase | Neutral | Street Light | of Cable | Phase | Neutral | Public lighting | |
mm2 | No. | No. | No. | mm | mm | mm | mm | Ω/km | Ω/km | Ω/km |
3x25+1x54.6+1x16 | 7 | 7 | 7 | 1.4 | 1.6 | 1.2 | 30.1 | 1.2 | 0.63 | 1.91 |
3x35+1x54.6+1x16 | 7 | 7 | 7 | 1.6 | 1.6 | 1.2 | 32.9 | 0.868 | 0.63 | 1.91 |
3x50+1x54.6+1x16 | 7 | 7 | 7 | 1.6 | 1.6 | 1.2 | 35.1 | 0.641 | 0.63 | 1.91 |
3x70+1x54.6+1x16 | 12 | 7 | 7 | 1.8 | 1.6 | 1.2 | 39.3 | 0.443 | 0.63 | 1.91 |
3x70+1x54.6+1x25 | 12 | 7 | 7 | 1.8 | 1.6 | 1.4 | 39.3 | 0.443 | 0.63 | 1.2 |
3x70+1x70+1x16 | 12 | 7 | 7 | 1.8 | 1.6 | 1.2 | 40.1 | 0.443 | 0.5 | 1.91 |
3x95+1x70+1x16 | 19 | 7 | 7 | 1.8 | 1.6 | 1.2 | 43.7 | 0.32 | 0.5 | 1.91 |
3x120+1x70+1x16 | 19 | 7 | 7 | 1.8 | 1.6 | 1.2 | 46.1 | 0.253 | 0.5 | 1.91 |
3x120+1x95+1x16 | 19 | 19 | 7 | 1.8 | 1.6 | 1.2 | 48.3 | 0.253 | 0.343 | 1.91 |
3x150+1x95+1x16 | 19 | 19 | 7 | 1.8 | 1.6 | 1.2 | 51.7 | 0.206 | 0.343 | 1.91 |
3x25+1x54.6+2x16 | 7 | 7 | 7 | 1.4 | 1.6 | 1.2 | 30.1 | 1.2 | 0.63 | 1.91 |
3x35+1x54.6+2x16 | 7 | 7 | 7 | 1.6 | 1.6 | 1.2 | 32.9 | 0.868 | 0.63 | 1.91 |
3x50+1x54.6+2x16 | 7 | 7 | 7 | 1.6 | 1.6 | 1.2 | 35.1 | 0.641 | 0.63 | 1.91 |
3x70+1x54.6+2x16 | 12 | 7 | 7 | 1.8 | 1.6 | 1.2 | 39.3 | 0.443 | 0.63 | 1.91 |
3x70+1x54.6+2x25 | 12 | 7 | 7 | 1.8 | 1.6 | 1.4 | 39.3 | 0.443 | 0.63 | 1.2 |
3x70+1x70+2x16 | 12 | 7 | 7 | 1.8 | 1.6 | 1.2 | 40.1 | 0.443 | 0.5 | 1.91 |
3x95+1x70+2x16 | 19 | 7 | 7 | 1.8 | 1.6 | 1.2 | 43.7 | 0.32 | 0.5 | 1.91 |
3x120+1x70+2x16 | 19 | 7 | 7 | 1.8 | 1.6 | 1.2 | 46.1 | 0.253 | 0.5 | 1.91 |
3x120+1x95+2x16 | 19 | 19 | 7 | 1.8 | 1.6 | 1.2 | 48.3 | 0.253 | 0.343 | 1.91 |
3x150+1x95+2x16 | 19 | 19 | 7 | 1.8 | 1.6 | 1.2 | 51.7 | 0.206 | 0.343 | 1.91 |
Number of Cores and Size | Min. No. of Wires | Nominal Insulation Thickness | Approx. Diameter of Cable | Max. DC. Resistance at 20ºC | Breaking Load | Approx .weight |
mm2 | No. | mm | mm | Ω/km | kN | kg/km |
1x10 | 6 | 1 | 5.8 | 3.08 | 1.65 | 41 |
1x16 | 6 | 1.2 | 7.2 | 1.91 | 2.517 | 65 |
1x25 | 6 | 1.2 | 8.4 | 1.2 | 3.762 | 94 |
1x35 | 6 | 1.4 | 9.8 | 0.868 | 5.177 | 129 |
1x50 | 6 | 1.4 | 10.9 | 0.641 | 7.011 | 166 |
1x70 | 12 | 1.4 | 12.6 | 0.443 | 10.354 | 229 |
1x95 | 15 | 1.6 | 14.8 | 0.32 | 13.727 | 315 |
1x120 | 15 | 1.6 | 16 | 0.253 | 17.339 | 386 |
1x150 | 15 | 1.8 | 18.1 | 0.206 | 21.033 | 476 |
1x185 | 30 | 2 | 20.1 | 0.164 | 26.732 | 594 |
1x240 | 30 | 2.2 | 22.8 | 0.125 | 34.679 | 777 |
1x300 | 30 | 2.2 | 24.9 | 0.1 | 43.349 | 955 |
1x400 | 53 | 2.2 | 27.6 | 0.0778 | 55.707 | 1205 |
2x10 | 6 | 1 | 11.6 | 3.08 | 1.65 | 84 |
2x16 | 6 | 1.2 | 14.4 | 1.91 | 2.517 | 131 |
2x25 | 6 | 1.2 | 16.8 | 1.2 | 3.762 | 189 |
2x35 | 6 | 1.4 | 19.6 | 0.868 | 5.177 | 261 |
2x50 | 6 | 1.4 | 21.8 | 0.641 | 7.011 | 336 |
2x70 | 12 | 1.4 | 25.2 | 0.443 | 10.354 | 463 |
2x95 | 15 | 1.6 | 29.6 | 0.32 | 13.727 | 637 |
2x120 | 15 | 1.6 | 32 | 0.253 | 17.339 | 779 |
4x10 | 6 | 1 | 14 | 3.08 | 1.65 | 167 |
4x16 | 6 | 1.2 | 17.4 | 1.91 | 2.517 | 262 |
4x25 | 6 | 1.2 | 20.3 | 1.2 | 3.762 | 378 |
4x35 | 6 | 1.4 | 23.7 | 0.868 | 5.177 | 522 |
4x50 | 6 | 1.4 | 26.4 | 0.641 | 7.011 | 672 |
4x70 | 12 | 1.4 | 30.5 | 0.443 | 10.354 | 926 |
4x95 | 15 | 1.6 | 35.8 | 0.32 | 13.727 | 1274 |
4x120 | 15 | 1.6 | 38.7 | 0.253 | 17.339 | 1558 |
GBT 12527
Nominal Size | Min. No. of Wires | Approx.Diameter of Conductor | Nominal Thickness of Insulation | Max. Diameter of Cable | Max. DC Resistance at 20°C | Breaking Load | |
Hard copper | Annealedcopper | Hard copper | |||||
mm2 | No. | mm | mm | mm | Ω/km | Ω/km | N |
10 | 6 | 3.8 | 1 | 6.5 | 1.906 | 1.83 | 3471 |
16 | 6 | 4.8 | 1.2 | 8 | 1.198 | 1.15 | 5486 |
25 | 6 | 6 | 1.2 | 9.4 | 0.749 | 0.727 | 8465 |
35 | 6 | 7 | 1.4 | 11 | 0.54 | 0.524 | 11731 |
50 | 6 | 8.4 | 1.4 | 12.3 | 0.399 | 0.387 | 16052 |
70 | 12 | 10 | 1.4 | 14.1 | 0.276 | 0.268 | 23461 |
95 | 15 | 11.6 | 1.6 | 16.5 | 0.199 | 0.193 | 31759 |
120 | 18 | 13 | 1.6 | 18.1 | 0.158 | 0.153 | 39911 |
150 | 18 | 14.6 | 1.8 | 20.2 | 0.128 | 0.124 | 49505 |
185 | 30 | 16.2 | 2 | 22.5 | 0.1021 | 0.0991 | 61846 |
240 | 34 | 18.4 | 2.2 | 25.6 | 0.0777 | 0.0754 | 79823 |
Henan Xunda Cable Co., Ltd., established in 2001, is a manufacturer specializing in the R&D and production of high-quality wires and cables. With over 20 years of experience, we provide reliable cable solutions, strengthened by our subsidiary, Xina Cable, for global reach and better service.
We produce a wide range of cables, including AAC, AAAC, ACSR, Power Cables (up to 35KV), Control Cables, Concentric Cables, Solar Cables, Building Wires, Nylon Wires, LSOH wires, and Branch Cables. Our products are widely used in power transmission, petrochemicals, metallurgy, construction, and infrastructure projects.
Located in the Industrial Zone of Gongyi, Zhengzhou City, Henan, China, our 30, 000m2 factory employs over 100 staff, including 20 senior technicians. With 30+ advanced production lines including high-speed drawing, stranding, and extrusion equipment, our daily bare conductor production capacity achieves more than 100 tons. Our strict quality control system and full-scale testing equipment ensure all products comply with ISO9001, CCC, and international standards, ensuring safety, durability, and reliability.
We have exported to over 20 countries, including Chile, Dominica, Panama, Colombia, Nicaragua, Peru, Philippines, Vietnam, Malaysia, Australia, PNG, Burundi, Tanzania, Madagascar, Angola among others. We provide 48-hour technical support, flexible payments, and efficient logistics for smooth transactions and timely delivery.
Our mission: Transmit Light, Connect World, Create Win-win, Grow together!
* Cutting-edge production and testing equipment ensures top-tier quality.
* Rigorously controlled raw materials for optimal standard adherence.
* Direct sales from the factory with competitive pricing, highlighting our dedication to quality sourcing.
* Comprehensive inquiry and consulting support available.
* Enjoy free sample and sample testing support to experience our product firsthand.
* Count on our swift delivery service to meet your timeline.
* Outstanding pre-sale and after-sale services to ensure complete satisfaction.