Soft Annealed Bare Copper Conductor for Grounding System

Product Details
Customization: Available
Application: Computer, Electronic, Automobile, RF, Home Appliance, Motorcycle
Wire Core Material: Steel Wire
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 30 days
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
CCC
to see all verified strength labels (22)
  • Soft Annealed Bare Copper Conductor for Grounding System
  • Soft Annealed Bare Copper Conductor for Grounding System
  • Soft Annealed Bare Copper Conductor for Grounding System
  • Soft Annealed Bare Copper Conductor for Grounding System
  • Soft Annealed Bare Copper Conductor for Grounding System
  • Soft Annealed Bare Copper Conductor for Grounding System
Find Similar Products

Basic Info.

Model NO.
Copper Conductor
Industry Type
Industrial Wire Harness
Bandaging Materials
None
General Wiring Harness
None
Signal
Low Voltage Wiring Harness
Shape
Round
Interface Type
AC/DC
Certification
VDE, RoHS, ISO9001, CCC
Brand
Xunda
Quality
100% Test It
Standard
Tbt ASTM BS Tbt
Construction
Concentrically Stranded Round Conduc
Transport Package
Wooden Drum, Steel Drum, Steel&Wooden Drum, Pallet
Specification
IEC 61089
Trademark
Xunda Cable
Origin
Henan
HS Code
7614900000
Production Capacity
3000 Tons/Month

Product Description

Copper Conductor


DESCRIPTION
Stranded bare copper and copper alloy are suitable for overhead power transmission systems and overhead electric traction systems.

APPLICATION
Stranded bare copper and copper alloy are suitable for overhead power transmission systems and overhead electric traction systems.

Soft Annealed Bare Copper Conductor for Grounding System

Standards 
•ASTM B 8    • BS 7884    • DIN 48201    • TBT 3111

BS 7884
Nominal area of cross-section of stranded conductor Construction (stranding and wire diameter) Overall diameter of conductor (approx.) Nominal mass per unit length Resistance at 20 °C Minimum breaking load
Nominal Max.
mm² number/mm mm kg/km Ω/km Ω/km N
10 7/1.35 4.05 89.82 1.788 1.829 3752
14 7/1.60 4.8 126.2 1.273 1.303 5267
16 3/2.65 5.7 148.3 1.082 1.106 6194
16 7/1.70 5.1 142.4 1.128 1.154 5946
25 7/2.10 6.3 217.3 0.7391 0.7563 9073
32 3/3.75 8.06 296.9 0.5405 0.552 12400
32 7/2.46 7.38 298.2 0.5386 0.5497 12442
35 7/2.50 7.5 308 0.5215 0.5337 12860
50 7/3.00 9 443.5 0.3622 0.3706 18520
50 19/1.80 9 435.8 0.3727 0.3819 17700
70 7/3.55 10.65 621.1 0.2586 0.2646 25930
70 19/2.10 10.5 593.2 0.2738 0.2806 24090
95 19/2.50 12.5 840.7 0.1932 0.198 34140
100 7/4.30 12.9 911.2 0.1763 0.181 36540
120 19/2.80 14 1055 0.154 0.1578 42830
125 19/2.90 14.5 1131 0.1436 0.1471 45940
150 19/3.20 16 1377 0.118 0.1208 55940
150 37/2.25 15.75 1334 0.1233 0.1264 53880
185 19/3.55 17.75 1695 0.09582 0.09815 68860
185 37/2.50 17.5 1647 0.09981 0.1024 66490
12 3/2.30 4.95 112.4 1.743 1.78 6968
16 7/1.70 5.1 143.3 1.368 1.399 8883
22 7/2.00 6 198.3 0.9882 1.011 12290
25 7/2.10 6.3 218.7 0.8959 0.9171 13550
30 7/2.30 6.9 262.3 0.7469 0.7645 16260
35 7/2.50 7.5 309.9 0.6324 0.6471 19210
38 7/2.60 7.8 335.2 0.5847 0.5983 20780
45 7/2.90 8.7 417 0.4698 0.4809 24600
55 7/3.20 9.6 507.8 0.3859 0.395 29950
70 19/2.10 10.5 596.8 0.3316 0.3403 35990
75 7/3.70 11.1 678.8 0.2887 0.2954 38010
95 19/2.50 12.5 845.9 0.2343 0.24 51010
100 7/4.30 12.9 916.9 0.2138 0.2195 51160
120 19/2.80 14 1061 0.1862 0.1914 60890
125 19/2.90 14.5 1138 0.1739 0.1784 65310
150 19/3.20 16 1386 0.1428 0.1465 79530
150 37/2.25 15.75 1342 0.1493 0.1533 80490
180 19/3.50 17.5 1658 0.1196 0.1225 95140
180 37/2.50 17.5 1657 0.1209 0.1242 99330
200 19/3.70 18.5 1853 0.1068 0.1696 100900
240 19/4.00 20 2165 0.09153 0.09378 117900

ASTM B 8
Size of Conductor Size of Conductor Nominal Conductor Diameter, inA Nominal ConductorDiameler, inA Nominal Conductor Diameler, inA Nominal Conductor Diameler, inA Nominal Conductor Diameler, inA   Mass Mass dc Resistance at 20°C dc Resistance at 20°C
Concentric Strand Concentric Strand Concentric Strand Concentric Strand Concentric Strand
cmil or AWG numbers mm2 Class A A Class A Class B Reverse Unilay Compressed Area in2 lbs/1000 ft kg/km Ω /1000 ft Ω/km
Concentric Diameter
Compreseed in
Class B  
Diameter  
in  
*5 000 000 cmil 2530 - 2.58 2 581 - - 3.927 15 890 23 649 0.00218 0.00715
4 500 000 cmil 2280 - 2.448 2.448 - - 3.534 14 300 21 283 0.00242 0.00794
4 000 000 cmil 2030 - 2.307 2 309 - - 3.142 12 590 18 738 0.0027 0.00888
3 500 000 cmil 1770 - 2.158 2159 - - 2.749 11 020 16 401 0.00308 0.0101
*3 000 000 cmil 1520 - 1.998 1.998 - - 2.356 9353 13 920 0.00356 0.0117
*2 500 000 cmil 1270 - 1.823 1. .824 - - 1.963 7 794 11 600 0.00427 0.014
*2 000 000 cmil 1010 - 1.63 1. .632 1.583 1.533 1.571 6175 9 190 0.00529 0.0174
1 900 000 cmil 963 - 1. 590 1. .590 1.542 1.494 1.492 5 866 8 730 0.00557 0.0183
1 800 000 omil 912 - 1. 547 1. .548 1.502 1.454 1.414 5558 8 272 0.00588 0.0193
*1 750 000 cmil 887 - 1.526 1.526 1 .480 1.434 1.374 5 403 8 041 0.00604 0.0198
1 700 000 cmil 861 - 1.504 1. 504 1.459 1.413 1.335 5249 7812 0.00622 0.0204
1 600 000 cmil 801 - 1.459 1.459 1.415 1.371 1.257 4 940 7352 0.00661 0.0217
*1 500 000 cmil 760 - 1.411 1.412 1.37 1.327 1.178 4 631 6 892 0.00705 0.0231
1 400 000 cmilt 709 - 1. 364 1. .364 1.323 1.282 1.1 4 323 6 435 0.00756 0.0248
1 300 000 cmil 659 - 1.314 1.315 1.275 1.236 1.021 4 014 5974 0.00814 0.0267
*1 250 000 cmil 633 - 1.288 1. .289 1.25 1.212 0.9817 3859 5 743 0.00846 0.0278
1 200 000 cmil 608 - 1.263 1.263 1.225 1.187 0.9425 3 705 5514 0.00882 0.0289
1 100 000 cmil 557 - 1. 209 1. 209 1.173 1.137 0.8639 3396 5 054 0.00962 0.0316
*1 000 000 cmil 507 1.151 1.152 1.152 1.117 1.084 0.7854 3088 4 596 0.0106 0.0348
900 000 cmil 456 1.092 1.094 1.094 1.06 1.028 0.7069 2779 4 136 0.0118 0.0387
*800 000 cmil 405 1.029 1.031 1.031 1 0.969 0.6283 2470 3676 0.0132 0.0433
*750 000 cmil 380 0.997 0.998 0.998 0.968 0.939 0.5800 2316 3447 0.0141 0.0462
*700 000 cmil 355 0.963 0.964 0.964 0.935 0.907 0.5498 2161 3216 0.0151 0.0495
650 000 cmil 329 0.928 0.929 0.929 0.901 0.874 0.5106 2007 2 987 0.0163 0.0535
*600 000 cmil 304 0.891 0.891 0.893 0.866 0.84 0.4712 1 853 2 758 0.0176 0.0578
550 000 cmil 279 0.853 0.853 0.855 0.829 0.804 0.432 1 698 2527 0.0192 0.063
*500 000 cmil 253 0.811 0.813 0.813 0.789 0.766 0.3927 1 544 2298 0.0212 0.0695
450 000 cmil 228 0.77 0.772 0.772 0.749 0.727 0 3534 1 389 2 067 0.0235 0.0771
*400 000 cmil 203 0.726 0.726 0.728 0.706 0.685 0.3142 1 235 1 838 0.0264 0.0866
*350 000 cmil 177 0.71 0.679 0.681 0.661 0.641 0.2749 1 081 1 609 0.0302 0.0991
*300 000 cmil 152 0.657 0.629 0.63 0.611 0.594 0.2356 926.3 1 378.6 0.0353 0.116
*250 000 amil 127 0.6 0.574 0.575 0.558 0.542 0.1963 771.9 1148.8 0.0423 0.139
* No.0000 107 0.522 0 522 0.528 0.512 0.498 0.1662 653.1 972 0.05 0.164
" No.000 85 0.464 0.464 0.47 0.456 0.443 0.1318 518.1 771.1 0.063 0.207
* No. 00 67.4 0.414 0.414 0.419 0.405 0.395 0.1045 410.9 611.5 0.0795 0.261
*No.0 53.5 0.368 0.368 0.373 0.362 0.352 0.08289 325.8 484.9 0.1 0.328
* No, 1,3 wire 42.4 0.36 - - - - 0.06573 255.9 380.9 0.126 0.413
* No. 1 42.4 - 0.328 0.332 0.322 0.313 0.06573 258.4 384.6 0.126 0.413
*No.2,3wire 33.6 0.32 - - - - 0.05213 202.9 301.9 0.159 0.522
*No.2 33.6 - 0.292 0.292 0.283 - 0.05213 204.9 304.9 0.159 0.522
*No.3.3wire 26.7 0.285 - - - - 0.04134 160.9 239.5 0.201 0.659
"No.3 26.7   0.26 0.26 0.252 - 0.04134 162.5 241.9 0.201 0.659
*No. 4, 3 wire 21.2 0.254 - - - - 0.03278 127.6 189.9 0.253 0.83
"No.4 21.2 - 232 0.232 0.225 - 0.03278 128.9 191.8 0.253 0.83
* No.5 16.8 - - 0.206 0.2 - 0.026 102.2 152.1 0.319 1.05
*No. 6 13.3 - - 0.184 0.178 - 0.02062 81.05 120.63 0.403 1.32
* No.7 10.6 - - 0.164 0.159 - 0.01635 64.28 95.67 0.509 1.67
* No.8 8.37 - - 0.146 0.142 - 0.01297 50.97 75.86 0.64 2.1
* No.9 6.63 - - 0.13 0.126 - 0.01028 40.42 60.16 0.809 2.65
* No. 10 5.26 - - 0.116 0.113 - 0.008155 32.06 47.72 1.02 3.35
* No. 12 3.31 - - 0.0915 0.089 - 0.005129 20.16 30 1.63 5.35
* No.14 2.08 - - 0.0726 0.071 - 0.003225 12.68 18.87 2.58 8.46
* No. 16 0.823 - - 0.0576 - - 0.002028 7.974 11.868 4.1 13.45
*No.18 0.519 - - 0.0456 - - 0.001276 5.015 7.484 6.54 21.46
* No.20 0.519 - - 0.0363 - - 0.0008023 3.154 4.694 10.3 33.8
* No.22 0.324 - - 0.0288 - - 0.0005067 1.992 2.965 16.4 53.8
* No.24 0.205 - - 0.0228 - - 0.0003176 1.249 1.859 26.1 85.6
- Class AA conductors are usually used in overhead lines where high strength and low flexibility are required.
- Class A conductors are suitable for covering with weather-resistant materials or for bare applications where more flexibility than Class AA is needed.
- Class B conductors are designed for insulating with various materials or for more flexible applications than Class A.
- Class C and D conductors offer even more flexibility than Class B and are used where extreme bending is required.


DIN 48201
Nominal area Cross- sectional Wire Overall Approx. mass per Rated strength Current carrying
mm2 area diameter unit length  kN capacity
  mm2 Number Diameter mm kg/km    A
    mm        
10 10.02 7 1.35 4.1 90 4.02 90
16 15.89 7 1.7 5.1 143 6.37 125
25 24.25 7 2.1 6.3 218 9.72 160
35 34.36 7 2.5 7.5 310 13.77 200
50 49.48 7 3 9 446 19.84 250
48.35 19 1.8 9 437 19.38 250
70 65.81 19 2.1 10.5 596 26.38 310
95 93.27 19 2.5 12.5 845 37.39 380
120 116.99 19 2.8 14 1060 46.9 440
150 147.11 37 2.25 15.8 1337 58.98 510
185 181.62 37 2.5 17.5 1649 72.81 585
240 242.54 61 2.25 20.3 2209 97.23 700
300 299.43 61 2.5 22.5 2725 120.04 800
400 400.14 61 2.89 26 3640 160.42 960
500 499.83 61 3.23 29.1 4545 200.38 1110
Note: Current carrying capacity are valid up to a frequency of 60 Hz,a wind velocity of 0.6 m/s, an initial ambient temperature of 35 °C and a conductor temperature of 70°C.

TBT 3111
Type Section area Calculated overall Structure Single wire diameter Single wire Stranded wire (Nominal)
mm2  diameter mm Min. tensile strength Min. Min. Mass per
  mm   MPa elongation breaking load unit length
Nominal Cross- sectional     Before After %  kN kg/km
    stranding stranding      
JT 70 65.81 10.5 1×19 2.1 430 410 0.7 27.45 596
JT 95 93.27 12.5 1×19 2.5 430 410 0.7 38.54 844
JT 120 116.99 14 1×19 2.8 430 410 0.7 48.01 1059
JT 150 147.12 15.75 1×37 2.25 430 410 0.7 61.21 1334
JTM 25 24.25 6.3 1×7 2.1 520 494 - 11.98 218
JTM 35 34.36 7.5 1×7 2.5 520 494 - 16.97 309
JTM 35 34.93 7.65 1×19 1.53 520 494 - 17.26 316
JTM 50 49.48 9 1×7 3 520 494 - 24.44 446
JTM 50 48.35 9 1×19 1.8 520 494 - 23.88 438
JTM 70 65.81 10.5 1×19 2.1 520 494 - 32.51 596
JTM 95 93.27 12.5 1×19 2.5 520 494 - 46.08 844
JTM 120 116.99 14 1×19 2.8 520 494 - 57.79 1059
JTM 150 147.12 15.75 1×37 2.25 520 494 - 72.67 1334
JTMH 25 24.25 6.3 1×7 2.1 620 589 - 14.28 218
JTMH 35 34.36 7.5 1×7 2.5 620 589 - 20.24 309
JTMH 35 34.93 7.65 1×19 1.53 620 589 - 20.57 316
JTMH 50 49.48 9 1×7 3 620 589 - 29.14 446
JTMH 50 48.35 9 1×19 1.8 620 589 - 28.48 438
JTMH 70 65.81 10.5 1×19 2.1 620 589 - 38.76 596
JTMH 95 93.27 12.5 1×19 2.5 620 589 - 54.94 844
JTMH 120 116.99 14 1×19 2.8 620 589 - 68.91 1059
JTMH 150 147.11 15.75 1×37 2.25 620 589 - 86.65 1334
JTMM 70 65.81 10.5 1×19 2.1 620 589 - 38.76 596
JTMM 95 93.27 12.5 1×19 2.5 620 589 - 54.94 844
JTMM 120 116.99 14 1×19 2.8 620 589 - 68.91 1059
JTMM 150 147.11 15.75 1×37 2.25 620 589 - 86.65 1334
JTCZ120 120 119.75 14.21 1×37 2.03 520 494 - 59.16 1092

  
Soft Annealed Bare Copper Conductor for Grounding System
Industry Solutions
Power grid
New energy
Building
Industry
Marine cable
Telecommunication
Railway
Instrument


Our Certificate
Soft Annealed Bare Copper Conductor for Grounding System
Company Information


Soft Annealed Bare Copper Conductor for Grounding SystemSoft Annealed Bare Copper Conductor for Grounding SystemSoft Annealed Bare Copper Conductor for Grounding SystemSoft Annealed Bare Copper Conductor for Grounding System
FAQ

1. Q:Are you a factory or trading company?
A: Manufacturing base in Henan ,China, with more than 150 workers.

2. Q:How can I visit there?
A: Sure,lf you need,we will arrange the driver to pick you up.

3. Q:How can I get some samples?
A: Contact me on below,Determine sample and address for shipping.

4. Q:Have you ever supplied cables to our country?
A: Xunda Cable have been sold to over 30 countries and regions in the world. you cancontact me for details.

5. Q:What is your MOQ?
A: MOQ Normally 1km for insulated cables(1 ton for bare conductor).Please contact mefor detail info if you have specific cable requirement.

6. Q:When can l get the price?
A: Usually quote within 3hours after we get your inquiry.

7. Q:How long is your delivery time?
A: According to your order's quantity.Usually our lead time is 3 - 20 working days.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier