This kind of spaced aerial cable ( SAC cable) is used for aerial power tranmission at 15/25/35 maximum system voltage. the phase to phase voltage is 10/20/33KV.
Construction
Conductor: Hard drawn aluminium wire according to the IEC 60228 standard.
Conductor screen: XLPE compound
Insulation: XLPE ( crosslinked polyethylene)
Jacket: Black XLPE
Specifications
• ICEA S-66-524 Cross-Linked-Thermosetting-Polyethylene-Insulated Wire and Cable for The Transmission and Distribution of Electrical Energy
• GB/T 14049 (Equal to IEC 60502-2) Aerial Insulated Cables For Rated Voltage of 10kV
| Nominal Size | Min.No. | Covering Thickness | Cable Diameter | Min. Breaking Load | Weight | ||||
| of Wires | Conductor Shield | Inner Layer | Outer Layer | ||||||
| mm2 | No. | mm | mm | mm | mm | N | kg/km | ||
| 3-Layer 15kV AAC/XLPE/XLPE | |||||||||
| 25 | 6 | 0.6 | 1.91 | 1.91 | 15.2 | 3762 | 218 | ||
| 35 | 6 | 0.6 | 1.91 | 1.91 | 16.2 | 5177 | 258 | ||
| 50 | 6 | 0.6 | 1.91 | 1.91 | 17.3 | 7011 | 307 | ||
| 70 | 12 | 0.6 | 1.91 | 1.91 | 19 | 10354 | 387 | ||
| 95 | 15 | 0.6 | 1.91 | 1.91 | 20.8 | 13727 | 482 | ||
| 120 | 15 | 0.6 | 1.91 | 1.91 | 22 | 17339 | 564 | ||
| 150 | 15 | 0.6 | 1.91 | 1.91 | 23.7 | 21033 | 660 | ||
| 185 | 30 | 0.6 | 1.91 | 1.91 | 25.3 | 26732 | 780 | ||
| 240 | 30 | 0.6 | 1.91 | 1.91 | 27.6 | 34679 | 968 | ||
| Nominal Size | Min. No. | Covering Thickness | Cable Diameter | Min. Breaking Load | Weight | ||||
| of Wires | Conductor Shield | Inner Layer | Outer Layer | ||||||
| mm2 | No. | mm | mm | mm | mm | N | kg/km | ||
| 3-Layer 15kV AAC/XLPE/HDPE | |||||||||
| 25 | 6 | 0.6 | 1.91 | 1.91 | 15.2 | 3762 | 221 | ||
| 35 | 6 | 0.6 | 1.91 | 1.91 | 16.2 | 5177 | 261 | ||
| 50 | 6 | 0.6 | 1.91 | 1.91 | 17.3 | 7011 | 310 | ||
| 70 | 12 | 0.6 | 1.91 | 1.91 | 19 | 10354 | 390 | ||
| 95 | 15 | 0.6 | 1.91 | 1.91 | 20.8 | 13727 | 486 | ||
| 120 | 15 | 0.6 | 1.91 | 1.91 | 22 | 17339 | 568 | ||
| 150 | 15 | 0.6 | 1.91 | 1.91 | 23.7 | 21033 | 664 | ||
| 185 | 30 | 0.6 | 1.91 | 1.91 | 25.3 | 26732 | 785 | ||
| 240 | 30 | 0.6 | 1.91 | 1.91 | 27.6 | 34679 | 973 | ||
25kV SAC Cable
| Nominal Size | Min. No. | Covering Thickness | Cable Diameter | Min. Breaking Load | Weight | ||
| of Wires | Conductor Shield | Inner Layer | Outer Layer | ||||
| mm2 | No. | mm | mm | mm | mm | N | kg/km |
| 3-Layer 25kV AAC/XLPE/XLPE | |||||||
| 25 | 6 | 0.7 | 3.18 | 3.18 | 20.1 | 3762 | 351 |
| 35 | 6 | 0.7 | 3.18 | 3.18 | 21.1 | 5177 | 398 |
| 50 | 6 | 0.7 | 3.18 | 3.18 | 22.2 | 7011 | 455 |
| 70 | 12 | 0.7 | 3.18 | 3.18 | 23.9 | 10354 | 548 |
| 95 | 15 | 0.7 | 3.18 | 3.18 | 25.7 | 13727 | 657 |
| 120 | 15 | 0.7 | 3.18 | 3.18 | 26.9 | 17339 | 748 |
| 150 | 15 | 0.7 | 3.18 | 3.18 | 28.6 | 21033 | 856 |
| 185 | 30 | 0.7 | 3.18 | 3.18 | 30.2 | 26732 | 989 |
| 240 | 30 | 0.7 | 3.18 | 3.18 | 32.5 | 34679 | 1195 |
| Nominal Size | Min. No. | Covering Thickness | Cable Diameter | Min. Breaking Load | Weight | ||
| of Wires | Conductor Shield | Inner Layer | Outer Layer | ||||
| mm2 | No. | mm | mm | mm | mm | N | kg/km |
| 3-Layer 25kV AAC/XLPE/HDPE | |||||||
| 25 | 6 | 0.7 | 3.18 | 3.18 | 20.1 | 3762 | 356 |
| 35 | 6 | 0.7 | 3.18 | 3.18 | 21.1 | 5177 | 404 |
| 50 | 6 | 0.7 | 3.18 | 3.18 | 22.2 | 7011 | 461 |
| 70 | 12 | 0.7 | 3.18 | 3.18 | 23.9 | 10354 | 555 |
| 95 | 15 | 0.7 | 3.18 | 3.18 | 25.7 | 13727 | 664 |
| 120 | 15 | 0.7 | 3.18 | 3.18 | 26.9 | 17339 | 755 |
| 150 | 15 | 0.7 | 3.18 | 3.18 | 28.6 | 21033 | 864 |
| 185 | 30 | 0.7 | 3.18 | 3.18 | 30.2 | 26732 | 997 |
| 240 | 30 | 0.7 | 3.18 | 3.18 | 32.5 | 34679 | 1203 |
35kV SAC Cable
| Nominal Size | Min. No. | Covering Thickness | Cable Diameter | Min. Breaking Load | Weight | ||
| of Wires | Conductor Shield | Inner Layer | Outer Layer | ||||
| mm2 | No. | mm | mm | mm | mm | N | kg/km |
| 3-Layer 35kV AAC/XLPE/XLPE | |||||||
| 25 | 6 | 0.7 | 4.45 | 3.18 | 22.6 | 3762 | 433 |
| 35 | 6 | 0.7 | 4.45 | 3.18 | 23.6 | 5177 | 485 |
| 50 | 6 | 0.7 | 4.45 | 3.18 | 24.7 | 7011 | 545 |
| 70 | 12 | 0.7 | 4.45 | 3.18 | 26.4 | 10354 | 645 |
| 95 | 15 | 0.7 | 4.45 | 3.18 | 28.2 | 13727 | 761 |
| 120 | 15 | 0.7 | 4.45 | 3.18 | 29.4 | 17339 | 856 |
| 150 | 15 | 0.7 | 4.45 | 3.18 | 31.1 | 21033 | 971 |
| 185 | 30 | 0.7 | 4.45 | 3.18 | 32.7 | 26732 | 1110 |
| 240 | 30 | 0.7 | 4.45 | 3.18 | 35 | 34679 | 1324 |
| Nominal Size | Min. No. | Covering Thickness | Cable Diameter | Min. Breaking Load | Weight | ||
| of Wires | Conductor Shield | Inner Layer | Outer Layer | ||||
| mm2 | No. | mm | mm | mm | mm | N | kg/km |
| 3-Layer 35kV AAC/XLPE/HDPE | |||||||
| 25 | 6 | 0.7 | 4.45 | 3.18 | 22.6 | 3762 | 439 |
| 35 | 6 | 0.7 | 4.45 | 3.18 | 23.6 | 5177 | 491 |
| 50 | 6 | 0.7 | 4.45 | 3.18 | 24.7 | 7011 | 552 |
| 70 | 12 | 0.7 | 4.45 | 3.18 | 26.4 | 10354 | 652 |
| 95 | 15 | 0.7 | 4.45 | 3.18 | 28.2 | 13727 | 768 |
| 120 | 15 | 0.7 | 4.45 | 3.18 | 29.4 | 17339 | 864 |
| 150 | 15 | 0.7 | 4.45 | 3.18 | 31.1 | 21033 | 980 |
| 185 | 30 | 0.7 | 4.45 | 3.18 | 32.7 | 26732 | 1119 |
| 240 | 30 | 0.7 | 4.45 | 3.18 | 35 | 34679 | 1334 |