Secured Trading Service

Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring

  • Audited Supplier
  • 2 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • High Performance PVC Material: Resistant to abrasion, moisture, sunlight, and oil for durable industrial use.
  • Certified Quality Standards: Complies with ISO9001, CE, CCC, RoHS, and IEC 60502-1 standards.
  • Robust Shielding Structure: Features galvanized steel tape shield for effective electromagnetic interference protection.
  • Wide Voltage Range: Suitable for AC rated voltage U0/U up to 0.6/1kV for fixed laying applications.
  • Customizable Options: Offers customized color and package length to meet specific project requirements.
  • Strict Quality Inspection: 100% finished product inspection including visual and functional checks.
  • Versatile Conductor Options: Available with Class 1, 2, or 5 solid, stranded, or soft copper conductors.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring

Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring pictures & photos
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring pictures & photos
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring pictures & photos
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring pictures & photos
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring pictures & photos
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring pictures & photos
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
  • Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
  • Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
    Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
  • Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
    Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
  • Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
    Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
  • Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
    Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
  • Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
    Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
  • Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
    Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring

Find Similar Products

Product Description

Product Details
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
 

 

Application
Good electrical and mechanical properties. Resistance to abrasion, moisture and sunlight. Adequate resistance to oil and abrasion.
This product is applicable to AC rated voltage U0/U is the control cable for fixed laying in control, monitoring circuit and protection circuit of (U0/U) 0.6/1kV and below.


 
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
 

 

CONSTRUCTION
Conductor: Conductor: Copper, class 1, 2, or 5, solid, stranded round or soft conductor

Insulation: Polyvinyl chloride PVC

Filler: Non-hygroscopic material

Binder: Non-hygroscopic material

Metal shield: Galvanized steel tape

Outer sheath: Polyvinyl chloride PV

 

Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring

SPECIFICATION

IEC 60228 Conductors of Insulate Cables

IEC 60502-1 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1kV(Um=1.2kV) up to 30kV(Um=36kV) - Part 1: Cables for Rated Voltages of 1kV (Um=1.2kV) and 3kV(Um=3.6kV)

Voltage Test
Each drum of finished cable should withstand power frequency voltage 3.5kV for 5 minutes,the insulation is not breakdown.
Service conditions and operation parameters of Cable:
The cable is applied to fixed installation for rated voltage 0.6/1kV of power transportation and distribution line.
Max. rated temperature of conductor. nominal operating 90ºC
Short circuit: max. for 5 sec.250ºC
The cable can be laid without drop restriction, and the environment temperature shall not be lower than 0ºC.

 

IEC 60502-1

    
No. of Cores
and Nominal
Cross Section
Conductor Type Nominal Insulation Thickness  Nominal Nominal Approx. Approx. Weight Max. D.C. Resistance
of Conductor
Copper Tape Thickness Sheath Thickness Overall Diameter at 20ºC 
No. × mm²   mm mm mm mm kg/km Ω/km
2×0.5 2 0.6 0.2 1.8 10.9 173 36
2×0.75 2 0.6 0.2 1.8 11.3 193 24.5
2×1 2 0.6 0.2 1.8 11.7 206 18.1
2×1.5 2 0.8 0.2 1.8 13.1 256 12.1
2×2.5 2 0.8 0.2 1.8 13.9 292 7.41
2×4 2 1 0.2 1.8 15.8 375 4.61
2×6 2 1 0.2 1.8 16.9 436 3.08
2×10 2 1 0.2 1.8 18.7 576 1.83
3×0.5 2 0.6 0.2 1.8 11.2 191 36
3×0.75 2 0.6 0.2 1.8 11.7 217 24.5
3×1 2 0.6 0.2 1.8 12.1 234 18.1
3×1.5 2 0.8 0.2 1.8 13.6 285 12.1
3×2.5 2 0.8 0.2 1.8 14.5 334 7.41
3×4 2 1 0.2 1.8 16.5 439 4.61
3×6 2 1 0.2 1.8 17.7 528 3.08
3×10 2 1 0.2 1.8 19.6 709 1.83
4×0.5 2 0.6 0.2 1.8 11.8 206 36
4×0.75 2 0.6 0.2 1.8 12.3 228 24.5
4×1 2 0.6 0.2 1.8 12.7 259 18.1
4×1.5 2 0.8 0.2 1.8 14.4 332 12.1
4×2.5 2 0.8 0.2 1.8 15.4 394 7.41
4×4 2 1 0.2 1.8 17.7 525 4.61
4×6 2 1 0.2 1.8 19 642 3.08
4×10 2 1 0.2 1.8 21.2 888 1.83
5×0.5 2 0.6 0.2 1.8 12.4 227 36
5×0.75 2 0.6 0.2 1.8 12.9 266 24.5
5×1 2 0.6 0.2 1.8 13.4 291 18.1
5×1.5 2 0.8 0.2 1.8 15.3 372 12.1
5×2.5 2 0.8 0.2 1.8 16.4 451 7.41
5×4 2 1 0.2 1.8 19 609 4.61
5×6 2 1 0.2 1.8 20.4 738 3.08
5×10 2 1 0.2 1.8 22.9 1042 1.83
6×0.5 2 0.6 0.2 1.8 13 248 36
6×0.75 2 0.6 0.2 1.8 13.6 279 24.5
               
 
No. of Cores
and Nominal
Cross Section
Conductor Type Nominal Insulation Thickness  Nominal Nominal Approx. Approx. Weight Max. D.C. Resistance
of Conductor
Copper Tape Thickness Sheath Thickness Overall Diameter at 20ºC 
No. × mm²   mm mm mm mm kg/km Ω/km
6×1 2 0.6 0.2 1.8 14.2 308 18.1
6×1.5 2 0.8 0.2 1.8 16.3 403 12.1
6×2.5 2 0.8 0.2 1.8 17.5 489 7.41
6×4 2 1 0.2 1.8 20.4 668 4.61
6×6 2 1 0.2 1.8 22 829 3.08
6×10 2 1 0.2 1.8 24.7 1133 1.83
7×0.5 2 0.6 0.2 1.8 13 255 36
7×0.75 2 0.6 0.2 1.8 13.6 288 24.5
7×1 2 0.6 0.2 1.8 14.2 320 18.1
7×1.5 2 0.8 0.2 1.8 16.3 423 12.1
7×2.5 2 0.8 0.2 1.8 17.5 519 7.41
7×4 2 1 0.2 1.8 20.4 717 4.61
7×6 2 1 0.2 1.8 22 889 3.08
7×10 2 1 0.2 1.8 24.7 1227 1.83
8×0.5 2 0.6 0.2 1.8 13.9 285 36
8×0.75 2 0.6 0.2 1.8 14.7 324 24.5
8×1 2 0.6 0.2 1.8 15.3 361 18.1
8×1.5 2 0.8 0.2 1.8 17.7 479 12.1
8×2.5 2 0.8 0.2 1.8 19.2 590 7.41
8×4 2 1 0.2 1.8 22.4 819 4.61
8×6 2 1 0.2 1.8 24.3 1016 3.08
8×10 2 1 0.2 1.8 27.4 1409 1.83
9×0.5 2 0.6 0.2 1.8 14.7 312 36
9×0.75 2 0.6 0.2 1.8 15.5 357 24.5
9×1 2 0.6 0.2 1.8 16.2 398 18.1
9×1.5 2 0.8 0.2 1.8 18.8 529 12.1
9×2.5 2 0.8 0.2 1.8 20.4 656 7.41
9×4 2 1 0.2 1.8 24 912 4.61
9×6 2 1 0.2 1.8 26 1139 3.08
9×10 2 1 0.2 1.9 29.7 1597 1.83
10×0.5 2 0.6 0.2 1.8 15.1 329 36
10×0.75 2 0.6 0.2 1.8 15.9 376 24.5
10×1 2 0.6 0.2 1.8 16.7 420 18.1
10×1.5 2 0.8 0.2 1.8 19.5 563 12.1
10×2.5 2 0.8 0.2 1.8 21.1 700 7.41
               
 
No. of Cores
and Nominal
Cross Section
Conductor Type Nominal Insulation Thickness  Nominal Nominal Approx. Approx. Weight Max. D.C. Resistance
of Conductor
Copper Tape Thickness Sheath Thickness Overall Diameter at 20ºC 
No. × mm²   mm mm mm mm kg/km Ω/km
10×4 2 1 0.2 1.8 24.9 979 4.61
10×6 2 1 0.2 1.8 27.1 1226 3.08
10×10 2 1 0.2 1.9 30.9 1721 1.83
12×0.5 2 0.6 0.2 1.8 15.4 348 36
12×0.75 2 0.6 0.2 1.8 16.3 402 24.5
12×1 2 0.6 0.2 1.8 17.1 453 18.1
12×1.5 2 0.8 0.2 1.8 20 615 12.1
12×2.5 2 0.8 0.2 1.8 21.7 772 7.41
12×4 2 1 0.2 1.8 25.6 1093 4.61
12×6 2 1 0.2 1.8 27.9 1376 3.08
14×0.5 2 0.6 0.2 1.8 16 377 36
14×0.75 2 0.6 0.2 1.8 16.9 437 24.5
14×1 2 0.6 0.2 1.8 17.7 495 18.1
14×1.5 2 0.8 0.2 1.8 20.8 677 12.1
14×2.5 2 0.8 0.2 1.8 22.6 857 7.41
14×4 2 1 0.2 1.8 26.8 1223 4.61
14×6 2 1 0.2 1.9 29.3 1562 3.08
16×0.5 2 0.6 0.2 1.8 16.6 409 36
16×0.75 2 0.6 0.2 1.8 17.6 477 24.5
16×1 2 0.6 0.2 1.8 18.4 542 18.1
16×1.5 2 0.8 0.2 1.8 21.7 745 12.1
16×2.5 2 0.8 0.2 1.8 23.7 949 7.41
16×4 2 1 0.2 1.8 28.1 1362 4.61
16×6 2 1 0.2 1.9 30.8 1744 3.08
19×0.5 2 0.6 0.2 1.8 17.2 446 36
19×0.75 2 0.6 0.2 1.8 18.3 524 24.5
19×1 2 0.6 0.2 1.8 19.2 599 18.1
19×1.5 2 0.8 0.2 1.8 22.7 832 12.1
19×2.5 2 0.8 0.2 1.8 24.8 1068 7.41
19×4 2 1 0.2 1.9 29.7 1559 4.61
19×6 2 1 0.2 2 32.9 2018 3.08
20×0.5 2 0.6 0.2 1.8 17.9 469 36
20×0.75 2 0.6 0.2 1.8 19 551 24.5
20×1 2 0.6 0.2 1.8 20 630 18.1
20×1.5 2 0.8 0.2 1.8 23.7 877 12.1
20×2.5 2 0.8 0.2 1.8 25.9 1126 7.41
               
 
No. of Cores
and Nominal
Cross Section
Conductor Type Nominal Insulation Thickness  Nominal Nominal Approx. Approx. Weight Max. D.C. Resistance
of Conductor
Copper Tape Thickness Sheath Thickness Overall Diameter at 20ºC 
No. × mm2   mm mm mm mm kg/km Ω/km
20×4 2 1 0.2 1.9 31.2 1643 4.61
20×6 2 1 0.2 2 34.9 2165 3.08
21×0.5 2 0.6 0.2 1.8 17.9 478 36
21×0.75 2 0.6 0.2 1.8 19 563 24.5
21×1 2 0.6 0.2 1.8 20 645 18.1
21×1.5 2 0.8 0.2 1.8 23.7 900 12.1
21×2.5 2 0.8 0.2 1.8 25.9 1159 7.41
21×4 2 1 0.2 1.9 31.2 1697 4.61
21×6 2 1 0.2 2 34.9 2238 3.08
22×0.5 2 0.6 0.2 1.8 18.6 501 36
22×0.75 2 0.6 0.2 1.8 19.8 591 24.5
22×1 2 0.6 0.2 1.8 20.8 677 18.1
22×1.5 2 0.8 0.2 1.8 24.8 946 12.1
22×2.5 2 0.8 0.2 1.8 27.2 1218 7.41
22×4 2 1 0.2 2 33.6 1845 4.61
22×6 2 1 0.5 2.1 38.1 2723 3.08
24×0.5 2 0.6 0.2 1.8 19.3 538 36
24×0.75 2 0.6 0.2 1.8 20.6 635 24.5
24×1 2 0.6 0.2 1.8 21.6 728 18.1
24×1.5 2 0.8 0.2 1.8 25.8 1019 12.1
24×2.5 2 0.8 0.2 1.8 28.4 1316 7.41
24×4 2 1 0.2 2 35.1 1995 4.61
24×6 2 1 0.5 2.2 39.9 2957 3.08
27×0.5 2 0.6 0.2 1.8 19.6 566 36
27×0.75 2 0.6 0.2 1.8 20.9 673 24.5
27×1 2 0.6 0.2 1.8 22 775 18.1
27×1.5 2 0.8 0.2 1.8 26.3 1094 12.1
27×2.5 2 0.8 0.2 1.9 29.1 1433 7.41
27×4 2 1 0.2 2.1 36 2178 4.61
27×6 2 1 0.5 2.2 40.7 3190 3.08
30×0.5 2 0.6 0.2 1.8 20.2 603 36
30×0.75 2 0.6 0.2 1.8 21.5 720 24.5
30×1 2 0.6 0.2 1.8 22.7 832 18.1
30×1.5 2 0.8 0.2 1.8 27.1 1180 12.1
30×2.5 2 0.8 0.2 1.9 30 1553 7.41
30×4 2 1 0.5 2.1 38.4 2726 4.61
               
 
No. of Cores
andNominal
Cross Section
Conductor Type Nominal Insulation Thickness  Nominal Nominal Approx. Approx. Weight Max. D.C. Resistance
of Conductor
Copper Tape Thickness Sheath Thickness Overall Diameter at 20ºC 
No. × mm²   mm mm mm mm kg/km Ω/km
30×6 2 1 0.5 2.3 42.2 3473 3.08
33×0.5 2 0.6 0.2 1.8 20.8 645 36
33×0.75 2 0.6 0.2 1.8 22.2 772 24.5
33×1 2 0.6 0.2 1.8 23.4 894 18.1
33×1.5 2 0.8 0.2 1.8 28.1 1272 12.1
33×2.5 2 0.8 0.2 1.9 31.1 1679 7.41
33×4 2 1 0.5 2.2 39.9 2953 4.61
33×6 2 1 0.5 2.3 43.7 3749 3.08
37×0.5 2 0.6 0.2 1.8 21.4 690 36
37×0.75 2 0.6 0.2 1.8 22.9 831 24.5
37×1 2 0.6 0.2 1.8 24.1 966 18.1
37×1.5 2 0.8 0.2 1.9 29.2 1395 12.1
37×2.5 2 0.8 0.2 2 32.7 1858 7.41
37×4 2 1 0.5 2.2 41.3 3208 4.61
37×6 2 1 0.5 2.4 45.4 4110 3.08
44×0.5 2 0.6 0.2 1.8 23.5 800 36
44×0.75 2 0.6 0.2 1.8 25.2 965 24.5
44×1 2 0.6 0.2 1.8 26.6 1125 18.1
44×1.5 2 0.8 0.2 2 32.9 1656 12.1
44×2.5 2 0.8 0.5 2.1 38.1 2589 7.41
44×4 2 1 0.5 2.4 46.6 3831 4.61
44×6 2 1 0.5 2.5 51.1 4884 3.08
48×0.5 2 0.6 0.2 1.8 23.8 836 36
48×0.75 2 0.6 0.2 1.8 25.5 1015 24.5
48×1 2 0.6 0.2 1.8 27 1186 18.1
48×1.5 2 0.8 0.2 2 33.8 1791 12.1
48×2.5 2 0.8 0.5 2.2 38.8 2752 7.41
48×4 2 1 0.5 2.4 47.3 4061 4.61
48×6 2 1 0.5 2.6 52.1 5215 3.08
52×0.5 2 0.6 0.2 1.8 24.4 883 36
52×0.75 2 0.6 0.2 1.8 26.1 1074 24.5
52×1 2 0.6 0.2 1.8 27.6 1259 18.1
52×1.5 2 0.8 0.2 2 34.6 1903 12.1
52×2.5 2 0.8 0.5 2.2 39.8 2917 7.41
52×4 2 1 0.5 2.5 48.7 4338 4.61
52×6 2 1 0.5 2.6 53.4 5556 3.08
               
 
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring




Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring

Shielded Copper Control Cable with PVC Sheath for Industrial Machine WiringShielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring

Shielded Copper Control Cable with PVC Sheath for Industrial Machine WiringShielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring

Shielded Copper Control Cable with PVC Sheath for Industrial Machine Wiring
 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASI259471". Items marked "verified" are certified.

Watch Video
Watch Video
Henan Xunda Cable Co., Ltd.
Henan Xunda Cable Co., Ltd.
Henan Xunda Cable Co., Ltd.
Henan Xunda Cable Co., Ltd.
Henan Xunda Cable Co., Ltd.
Henan Xunda Cable Co., Ltd.
Henan Xunda Cable Co., Ltd.
Henan Xunda Cable Co., Ltd.

About Our Factory & Business Background

Address
Industrial Zone of Gongyi, Zhengzhou City, Henan, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, CFR, CIF
Average Lead Time
Peak Season Lead Time: 1-3 months
Off Season Lead Time: one month
Nearest Port
QINGDAO, TIANJIN, SHANGHAI

Our Production Capability & Technical Expertise

Main Products
AAC AAAC ACSR Power Cables (up to 35kv) Cont
verified Production Lines
27
verified Production Machines
Annealing furnace, Wire drawing machine, Stranding machine, Armored machine, Cabling machine, Extrusion machine
verified QA/QC inspectors
5 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Designs, Full Customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
5 people
verified Traceability of Raw Materials
Yes

Our Industry Experience & Global Business Record

Export Year
2025-04-14
Main Markets
North America, South America, Eastern Europe, Southeast Asia
verified New Products Launched in Last year
No

FAQ

What are the main applications for this cable?
It is applicable for fixed laying in control, monitoring, and protection circuits of power transportation and distribution lines with rated voltage up to 0.6/1kV.
What certifications does the product have?
The product is certified with ISO9001, CE, CCC, and RoHS, and complies with IEC 60502-1 standards.
Is customization available for this cable?
Yes, ODM and OEM services are available. Customized color and package length options are offered.
What is the minimum order quantity (MOQ)?
The MOQ is 1000 meters.
What is the lead time for production?
The lead time is one month during the off-season and 1-3 months during the peak season.
What payment terms are accepted?
Accepted payment terms include LC, T/T, D/P, PayPal, Western Union, Small-amount payment, and Money Gram.
How is the quality controlled?
We perform 100% inspection on finished products, including visual and functional inspections, following uniform instructions.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now