AAAC Overhead Electrical Conductor Cable for Power Distribution Line
|
Still deciding? Get samples of $ !
Order Sample
|
Product Details
| Customization: | Available |
|---|---|
| Type: | Bare |
| Conductor Type: | Stranded |
Shipping
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Payment Guarantee
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Secured Trading Service
Diamond Member Since 2025
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Importers and Exporters
Fast Delivery
Management Certification
Product Certification
The supplier has import and export rights
The supplier can deliver the goods within 30 days
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
The supplier's products already have relevant certification qualifications, including:
CE
CCC
CE
CCC
Sign In to see all verified strength labels (22)
Find Similar Products
Basic Info.
- Model NO.
- AAAC
- Application
- Overhead
- Conductor Material
- Aluminum
- Insulation Material
- Bare
- Material Shape
- Round Wire
- Range of Application
- Power Translation and Distribution
- Certification
- ISO9001, CE, CCC
- Brand
- Xunda
- Product Capacity
- 100ton/Day
- Material
- AAAC
- Voltage Rate
- Low and Medium Voltage, High Voltage
- Conductivity
- 52%-61% Iacs
- Rated Temperature
- 70-150 ºC
- Ampacity
- 5A/mm2
- Elastic Modulus
- 70gpa
- Standard
- IEC 61089 ASTM B399
- Package Length
- Customized
- Third Party Inspection
- Yes
- Ome Accepted
- Yes
- Transport Package
- Drum
- Specification
- 16-1000mm2
- Trademark
- XUNDA
- Origin
- China
- HS Code
- 7614900000
- Production Capacity
- 500km/Month
Packaging & Delivery
- Package Size
- 100.00cm * 100.00cm * 100.00cm
- Package Gross Weight
- 1000.000kg
Product Description
AAC is used mainly in urban areas where the spacing is short and the supports are close. All aluminium conductors are made up of one or more strands of aluminium wire depending on the end usage. AAC is also used extensively in coastal regions because it has a high degree of corrosion resistance.Concentric lay stranded Aluminium Conductors (AAC) are made out of Hard-Drawn aluminum wires.
AAAC is used as a bare overhead conductor for power transmission and distribution lines, on aerial circuits that require a larger mechanical resistance than AAC, and a better corrosion resistance than ACSR. The sag characteristics and the strength-to-weight ratio of AAAC is better than both AAC / ACSR.Concentric lay stranded Aluminium Alloy Conductors (AAAC) are made out of high strength Aluminium-Magnesium-Silicon Alloy.
Used as bare overhead transmission conductor and as primary and secondary distribution conductor and messenger support. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
Aluminium Conductor Steel Reinforced (ACSR) is concentrically stranded conductor with one or more layers of hard drawn aluminium wire on galvanized steel wire core. The core can be single wire or stranded depending on the size. Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease
SPECIFICATION
IEC 61089
AAAC/A2
| Code | Area | No.of | Diameter | Linear | Rated | D.C. | |
| Number | Wires | Wire | Cond. | Mass | Strength | Resistance | |
| mm2 | mm | mm | kg/km | kN | Ω/km | ||
| 16 | 18.4 | 7 | 1.83 | 5.49 | 50.4 | 5.43 | 1.7896 |
| 25 | 28.8 | 7 | 2.29 | 6.86 | 78.7 | 8.49 | 1.1453 |
| 40 | 46 | 7 | 2.89 | 8.68 | 125.9 | 13.58 | 0.7158 |
| 63 | 72.5 | 7 | 3.63 | 10.9 | 198.3 | 21.39 | 0.4545 |
| 100 | 115 | 19 | 2.78 | 13.9 | 316.3 | 33.95 | 0.2877 |
| 125 | 144 | 19 | 3.1 | 15.5 | 395.4 | 42.44 | 0.2302 |
| 160 | 184 | 19 | 3.51 | 17.6 | 506.1 | 54.32 | 0.1798 |
| 200 | 230 | 19 | 3.93 | 19.6 | 632.7 | 67.91 | 0.1439 |
| 250 | 288 | 19 | 4.39 | 22 | 790.8 | 84.88 | 0.1151 |
| 315 | 363 | 37 | 3.53 | 24.7 | 998.9 | 106.95 | 0.0916 |
| 400 | 460 | 37 | 3.98 | 27.9 | 1268.4 | 135.81 | 0.0721 |
| 450 | 518 | 37 | 4.22 | 29.6 | 1426.9 | 152.79 | 0.0641 |
| 500 | 575 | 37 | 4.45 | 31.2 | 1585.5 | 169.76 | 0.0577 |
| 560 | 645 | 61 | 3.67 | 33 | 1778.4 | 190.14 | 0.0516 |
| 630 | 725 | 61 | 3.89 | 35 | 2000.7 | 213.9 | 0.0458 |
| 710 | 817 | 61 | 4.13 | 37.2 | 2254.8 | 241.07 | 0.0407 |
| 800 | 921 | 61 | 4.38 | 39.5 | 2540.6 | 271.62 | 0.0361 |
| 900 | 1036 | 91 | 3.81 | 41.8 | 2861.1 | 305.58 | 0.0321 |
| 1000 | 1151 | 91 | 4.01 | 44.1 | 3179 | 339.53 | 0.0289 |
| 1120 | 1289 | 91 | 4.25 | 46.7 | 3560.5 | 380.27 | 0.0258 |
| 1250 | 1439 | 91 | 4.49 | 49.4 | 3973.7 | 424.41 | 0.0231 |
AAAC / A3
| Code | Area | No.of | Diameter | Linear | Rated | D.C. | |
| Number | Wires | Wire | Cond. | Mass | Strength | Resistance | |
| mm2 | mm | mm | kg/km | kN | Ω/km | ||
| 16 | 18.6 | 7 | 1.84 | 5.52 | 50.8 | 6.04 | 1.7896 |
| 25 | 29 | 7 | 2.3 | 6.9 | 79.5 | 9.44 | 1.1453 |
| 40 | 46.5 | 7 | 2.91 | 8.72 | 127.1 | 15.1 | 0.7158 |
| 63 | 73.2 | 7 | 3.65 | 10.9 | 200.2 | 23.06 | 0.4545 |
| 100 | 116 | 19 | 2.79 | 14 | 319.3 | 37.76 | 0.2877 |
| 125 | 145 | 19 | 3.12 | 15.6 | 399.2 | 47.2 | 0.2302 |
| 160 | 186 | 19 | 3.53 | 17.6 | 511 | 58.56 | 0.1798 |
| 200 | 232 | 19 | 3.95 | 19.7 | 638.7 | 73.2 | 0.1439 |
| 250 | 290 | 19 | 4.41 | 22.1 | 798.4 | 91.5 | 0.1151 |
| 315 | 366 | 37 | 3.55 | 24.8 | 1008.4 | 115.29 | 0.0916 |
| 400 | 465 | 37 | 4 | 28 | 1280.5 | 146.4 | 0.0721 |
| 450 | 523 | 37 | 4.24 | 29.7 | 1440.5 | 164.7 | 0.0641 |
| 500 | 581 | 37 | 4.47 | 31.3 | 1600.6 | 183 | 0.0577 |
| 560 | 651 | 61 | 3.69 | 33.2 | 1795.3 | 204.96 | 0.0516 |
| 630 | 732 | 61 | 3.91 | 35.2 | 2019.8 | 230.58 | 0.0458 |
| 710 | 825 | 61 | 4.15 | 37.3 | 2276.2 | 259.86 | 0.0407 |
| 800 | 930 | 61 | 4.4 | 39.6 | 2564.8 | 292.8 | 0.0361 |
| 900 | 1046 | 91 | 3.83 | 42.1 | 2888.3 | 329.4 | 0.0321 |
| 1000 | 1162 | 91 | 4.03 | 44.4 | 3209.3 | 366 | 0.0289 |
| 1120 | 1301 | 91 | 4.27 | 46.9 | 3594.4 | 409.92 | 0.0258 |
ASTM B 399
AAAC| Conductor Size | No. and Diameter | Overall Diameter | Mass | Rated Strength | Nominal DC Resistance at 20ºC | |
| AWG or MCM | mm2 | mm | mm | kg/km | kN | Ω/km |
| 6 | 13.2 | 7/1.55 | 4.65 | 36.2 | 4.18 | 2.5361 |
| 4 | 21.1 | 7/1.96 | 5.88 | 57.9 | 6.69 | 1.586 |
| 2 | 33.5 | 7/2.47 | 7.41 | 92 | 10.6 | 0.9987 |
| 1/0 | 53.5 | 7/3.12 | 9.36 | 146.8 | 17 | 0.62592 |
| 2/0 | 67.3 | 7/3.50 | 10.5 | 184.8 | 20.4 | 0.49738 |
| 3/0 | 84.9 | 7/3.93 | 11.79 | 233 | 25.7 | 0.3945 |
| 4/0 | 107 | 7/4.42 | 13.26 | 294.7 | 32.5 | 0.31188 |
| 250 | 126 | 19/2.91 | 14.55 | 346.7 | 38.8 | 0.26509 |
| 300 | 152 | 19/3.19 | 15.95 | 416.7 | 46.6 | 0.22059 |
| 350 | 178 | 19/3.45 | 17.25 | 487.3 | 52 | 0.1886 |
| 400 | 203 | 19/3.69 | 18.45 | 557.5 | 59.5 | 0.16486 |
| 450 | 228 | 19/3.91 | 19.55 | 626 | 66.8 | 0.14683 |
| 500 | 253 | 19/4.12 | 20.6 | 695 | 74.2 | 0.13224 |
| 550 | 279 | 37/3.10 | 21.7 | 766.2 | 83.9 | 0.11995 |
| 600 | 303 | 37/3.23 | 22.61 | 831.9 | 91 | 0.11049 |
| 650 | 330 | 37/3.37 | 23.59 | 905.5 | 94.9 | 0.1015 |
| 700 | 354 | 37/3.49 | 24.43 | 971.2 | 101 | 0.09464 |
| 750 | 381 | 37/3.62 | 25.34 | 1045 | 109 | 0.08796 |
| 800 | 404 | 37/3.73 | 26.11 | 1109 | 116 | 0.08285 |
| 900 | 456 | 37/3.96 | 27.72 | 1250 | 131 | 0.07351 |
| 1000 | 508 | 37/4.18 | 29.26 | 1393 | 146 | 0.06597 |
| Code Name | Conductor Size | No. and Diameter | Overall Diameter | Mass | Rated Strength | Nominal DC Resistance at 20ºC | |
| MCM | mm2 | mm | mm | kg/km | kN | Ω/km | |
| AKRON | 30.58 | 15.5 | 7/1.68 | 5.04 | 42.58 | 4.92 | 2.159 |
| ALTON | 48.69 | 24.7 | 7/2.12 | 6.36 | 67.8 | 7.83 | 1.356 |
| AMES | 77.47 | 39.2 | 7/2.67 | 8.01 | 107.5 | 12.4 | 0.8547 |
| AZUSA | 123.3 | 62.4 | 7/3.37 | 10.11 | 171.3 | 18.9 | 0.5365 |
| ANAHEIM | 155.4 | 78.6 | 7/3.78 | 11.34 | 215.6 | 23.8 | 0.4264 |
| AMHERST | 195.7 | 99.3 | 7/4.25 | 12.75 | 272.5 | 30 | 0.3373 |
| ALLIANCE | 246.9 | 125 | 7/4.77 | 14.31 | 343.2 | 37.8 | 0.2678 |
| BUTTE | 312.8 | 159 | 19/3.26 | 16.3 | 435.1 | 46.5 | 0.2112 |
| CANTON | 394.5 | 200 | 19/3.66 | 18.3 | 548.5 | 58.6 | 0.1676 |
| CAIRO | 465.4 | 236 | 19/3.98 | 19.9 | 648.6 | 69.2 | 0.1417 |
| DARIEN | 559.5 | 284 | 19/4.36 | 21.8 | 778.3 | 83.1 | 0.1181 |
| ELGIN | 652.4 | 331 | 19/4.71 | 23.55 | 908.3 | 97 | 0.1012 |
| FLINT | 740.8 | 375 | 37/3.59 | 25.13 | 1028 | 107 | 0.08944 |
| GREELEY | 927.2 | 470 | 37/4.02 | 28.14 | 1289 | 135 | 0.07133 |
Send your message to this supplier
People who viewed this also viewed
Product Groups
Find Similar Products By Category
- Supplier Homepage
- Products
- Aluminum Bare Conductor
- All Aluminum Alloy Conductor
- AAAC Overhead Electrical Conductor Cable for Power Distribution Line
Related Categories
Hot Searches
More