Application
Building Wire H07-K 450-750V
The versatile H07V-K (RV) wire is specifically crafted for installation within electric tubes, whether under or on plaster, in the dry atmosphere of closed installation conduits. Ideal for internal wiring, this wire suits distribution and switching box equipment perfectly. Please note, direct installation in cable guides is restricted to ensure optimal performance.
Building Wire H07-R 450-750V
Engineered for excellence, H07V-R (BVR) wire is tailored for electric installations in tubes, beneath or above plaster in dry enclosures. Its application extends to the internal wiring of distribution and switching boxes, ensuring reliable performance. However, for maximum safety and efficiency, it should not be laid directly in cable guides.
Building Wire H07-U 450-750V
H07V-U(BV) is meticulously designed for electric installation within tubes, either under or on plaster in dry, closed installation conduits. It is ideally suited for internal wiring applications within distribution and switching boxes. Direct placement in cable guides is not advised for maintaining optimal functionality and safety.
Construction
Conductor: Constructed with premium copper for unparalleled conductivity, featuring class 1 solid conductors for superior durability.
Insulation: High-quality PVC for enhanced safety and reliability, ensuring exceptional insulation properties.
Building Wire H07-R 450-750V
Compliant with IEC 60228 Conductors of Insulated Cables, ensuring supreme quality and reliability.
Adhering to IEC 60227-3 standards, this product features Polyvinyl Chloride Insulated Cables for voltages up to and including 450/750 V - ideal for non-sheathed cables used in fixed wiring applications.
Aligned with DIN VED 0281-3 standards, offering excellence in Polyvinyl Chloride Insulated Cables for voltages up to and including 450/750 V, perfect for non-sheathed cables in fixed wiring scenarios.
Boasting a rated voltage Uo/U of 450/750 V, these cables deliver dependable performance.
Designed for a normal operating temperature of 70˚C, these cables ensure consistent and safe functionality.
In the event of a short circuit, these cables can withstand temperatures up to 160˚C for a maximum of 5 seconds, showcasing robust durability.
IEC 60227-3 (mark 60227 IEC 01)
Minimum bending radius:
4D for D < 8mm, offering flexibility for smaller diameters.
5D for 8mm < D < 12mm, ensuring optimal usability for medium-sized cables.
6D for D > 12mm, providing robust support for larger cables.
Note: D is the overall diameter of the cable, ensuring clarity and precision in installation.
Building Wire H07-K 450-750V
Compliant with IEC 60228 Conductors of Insulated Cables, promising exceptional quality and performance.
Following IEC 60227-3 standards, these cables feature Polyvinyl Chloride Insulation for voltages up to 450/750 V - perfect for fixed wiring applications without sheathing.
In line with DIN VED 0281-3 standards, these cables offer superior Polyvinyl Chloride Insulation for voltages up to 450/750 V, ideal for fixed wiring applications without sheathing.
Rated voltage Uo/U: 450/750 V, ensuring reliable and efficient power delivery.
Operating comfortably at a normal temperature of 70˚C, safeguarding consistent performance.
Capable of enduring short circuit temperatures up to 160˚C for up to 5 seconds, showcasing resilience and reliability.
IEC 60227-3 (mark 60227 IEC 01)
Minimum bending radius:
4D for D < 8mm, enhancing versatility for smaller cables.
5D for 8mm < D < 12mm, ensuring optimal performance for medium cables.
6D for D > 12mm, supporting larger cables with robustness.
Note: D represents the overall diameter of the cable, aiding in precision during installation.
Building Wire H07-U 450-750V
Adheres to IEC 60228 standards for Conductors of Insulated Cables, guaranteeing high quality and dependability.
Complies with IEC 60227-3 standards, offering Polyvinyl Chloride Insulated Cables for voltages up to 450/750 V - a perfect fit for fixed wiring without sheathing.
Meets DIN VED 0281-3 standards, providing Polyvinyl Chloride Insulated Cables for voltages up to 450/750 V, tailored for fixed wiring applications without sheathing.
Rated voltage Uo/U: 450/750 V, ensuring stability and efficiency in power transmission.
Works optimally at a normal operating temperature of 70˚C, ensuring reliability.
Built to withstand short circuit temperatures up to 160˚C for 5 seconds, demonstrating robust durability.
IEC 60227-3 (mark 60227 IEC 01)
Minimum bending radius:
4D for D < 8mm, providing flexibility for smaller diameters.
5D for 8mm < D < 12mm, ensuring adaptability for mid-sized cables.
6D for D > 12mm, delivering robust support for large diameter cables.
Note: 'D' denotes the comprehensive diameter of the cable, ensuring optimal fit and performance.
| Conductor | Insulation Thickness | Overall Diameter | Approx. Weight | Max. D.C. Resistance of Conductor | Allowable Ampacities | ||
| at 20ºC | |||||||
| Min. | Max. | ||||||
| mm2 | Class of | mm | mm | mm | kg/km | Ω/km | A |
| Conductor | |||||||
| 1.5 | 1 | 0.7 | 2.6 | 3.2 | 21 | 12.1 | 18 |
| 2.5 | 1 | 0.8 | 3.2 | 3.9 | 32 | 7.41 | 25 |
| 4 | 1 | 0.8 | 3.6 | 4.4 | 47 | 4.61 | 33 |
| 6 | 1 | 0.8 | 4.1 | 5 | 65 | 3.08 | 42 |
| 10 | 1 | 1 | 5.3 | 6.4 | 110 | 1.83 | 58 |
H07V-R (BVR): This flexible wire is perfect for house wiring, providing versatile and efficient copper cable solutions.
| Conductor | Insulation Thickness | Overall Diameter | Approx. Weight | Max. D.C. | Allowable Ampacities | ||
| Resistance of Conductor | |||||||
| at 20ºC | |||||||
| Min. | Max. | ||||||
| mm2 | Class of | mm | mm | mm | kg/km | Ω/km | A |
| Conductor | |||||||
| 1.5 | 2 | 0.7 | 2.7 | 3.3 | 22 | 12.1 | 18 |
| 2.5 | 2 | 0.8 | 3.3 | 4 | 35 | 7.41 | 25 |
| 4 | 2 | 0.8 | 3.8 | 4.6 | 50 | 4.61 | 33 |
| 6 | 2 | 0.8 | 4.3 | 5.2 | 70 | 3.08 | 42 |
| 10 | 2 | 1 | 5.6 | 6.7 | 112 | 1.83 | 58 |
| 16 | 2 | 1 | 6.4 | 7.8 | 169 | 1.15 | 78 |
| 25 | 2 | 1.2 | 8.1 | 9.7 | 262 | 0.727 | 105 |
| 35 | 2 | 1.2 | 9 | 10.9 | 357 | 0.524 | 130 |
| 50 | 2 | 1.4 | 10.6 | 12.8 | 497 | 0.387 | 155 |
| 70 | 2 | 1.4 | 12.1 | 14.6 | 675 | 0.268 | 200 |
| 95 | 2 | 1.6 | 14.1 | 17.1 | 936 | 0.193 | 250 |
| 120 | 2 | 1.6 | 15.6 | 18.8 | 1161 | 0.153 | 290 |
| 150 | 2 | 1.8 | 17.3 | 20.9 | 1444 | 0.124 | 335 |
| 185 | 2 | 2 | 19.3 | 23.3 | 1801 | 0.0991 | 390 |
| 240 | 2 | 2.2 | 22 | 26.6 | 2354 | 0.0754 | 470 |
| 300 | 2 | 2.4 | 24.5 | 29.6 | 2887 | 0.0601 | 240 |
| 400 | 2 | 2.6 | 27.5 | 33.2 | 3825 | 0.047 | 635 |
| Conductor | Insulation Thickness | Overall Diameter | Approx. Weight | Max. D.C. Resistance of Conductor | Allowable Ampacities | ||
| at 20ºC | |||||||
| Min. | Max. | ||||||
| mm2 | Class of | mm | mm | mm | kg/km | Ω/km | A |
| Conductor | |||||||
| 1.5 | 5 | 0.7 | 2.8 | 3.4 | 21 | 13.3 | 18 |
| 2.5 | 5 | 0.8 | 3.4 | 4.1 | 34 | 7.98 | 25 |
| 4 | 5 | 0.8 | 3.9 | 4.8 | 50 | 4.95 | 33 |
| 6 | 5 | 0.8 | 4.4 | 5.3 | 71 | 3.3 | 42 |
| 10 | 5 | 1 | 5.7 | 6.8 | 107 | 1.91 | 58 |
| 16 | 5 | 1 | 6.7 | 8.1 | 169 | 1.21 | 78 |
| 25 | 5 | 1.2 | 8.4 | 10.2 | 266 | 0.78 | 105 |
| 35 | 5 | 1.2 | 9.7 | 11.7 | 347 | 0.554 | 130 |
| 50 | 5 | 1.4 | 11.5 | 13.9 | 486 | 0.386 | 155 |
| 70 | 5 | 1.4 | 13.2 | 16 | 705 | 0.272 | 200 |
| 95 | 5 | 1.6 | 15.1 | 18.2 | 905 | 0.206 | 250 |
| 120 | 5 | 1.6 | 16.7 | 20.2 | 1117 | 0.161 | 290 |
| 150 | 5 | 1.8 | 18.6 | 22.5 | 1380 | 0.129 | 335 |
| 185 | 5 | 2 | 20.6 | 24.9 | 1742 | 0.106 | 390 |
| 240 | 5 | 2.2 | 23.5 | 28.4 | 2152 | 0.0801 | 470 |