- Customized Color and Package: Color and Package Length are fully customizable to meet specific project requirements.
- High-Quality Copper Conductors: Uses Class 1, 2, or 5 stranded copper conductors for excellent electrical conductivity.
- Durable PVC Insulation and Sheath: Polyvinyl chloride materials provide resistance to abrasion, moisture, oil, and sunlight.
- Wide Voltage Range Application: Suitable for AC rated voltage U0/U up to 0.6/1kV in control and monitoring circuits.
- Comprehensive Certifications: Certified by ISO9001, CE, and CCC standards ensuring global quality compliance.
- Strict Quality Inspection: 100% visual and function inspection with third-party inspection available upon request.
- ODM and OEM Services: Full customization and design services available for ODM and OEM requirements.
Product Attributes
- Customization
- Available
- Type
- Insulated
- Conductor Type
- Stranded
- Model NO.
- KVV
- Application
- Overhead
- Conductor Material
- Copper
- Sheath Material
- PVC
- Insulation Material
- PVC
- Material Shape
- Round Wire
- Range of Application
- LSOH
- Certification
- ISO9001, CE, CCC
- Brand
- Xunda
- Rated Voltage
- 600/1000V
- Rated Temperature
- 80/105 ºC
- Resisitivity
- 17.421
- Voltage Test
- Yes
- Ampacity
- 8A/mm2
- Core
- Muticore
- Standard
- IEC 60228, IEC 60502-1
- Insulation Thickness
- 0.6-1mm
- Sheath Thickness
- 1.8-2.1
- MOQ
- 1000m
- ODM Available
- Yes
- Color
- Customized
- Package Length
- Customized
- Third Party Inspection
- Available
- Environment Friendly
- Yes
- Transport Package
- Drum/Tray
- Specification
- 0.5-10mm2
- Trademark
- XUNDA
- Origin
- China
- HS Code
- 8544492900
- Production Capacity
- 100km/Month
- Package Size
- 100.00cm * 100.00cm * 100.00cm
- Package Gross Weight
- 1000.000kg
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of Flexible Copper Conductor Multicore PVC Insulated Control Cable for Automation
Find Similar Products
Product Description
Application
Good electrical and mechanical properties. Resistance to abrasion, moisture and sunlight. Adequate resistance to oil and abrasion.
This product is applicable to AC rated voltage U0/U is the control cable for fixed laying in control, monitoring circuit and protection circuit of (U0/U) 0.6/1kV and below.
CONSTRUCTION
Conductor: Conductor: Copper, class 1, 2, or 5, solid, stranded round or soft conductor
Insulation: Polyvinyl chloride PVC
Filler: Non-hygroscopic material
Binder: Non-hygroscopic material
Outer sheath: Polyvinyl chloride PV
SPECIFICATION
IEC 60228 Conductors of Insulate Cables
IEC 60502-1 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1kV(Um=1.2kV) up to 30kV(Um=36kV) - Part 1: Cables for Rated Voltages of 1kV (Um=1.2kV) and 3kV(Um=3.6kV)
Voltage Test
Each drum of finished cable should withstand power frequency voltage 3.5kV for 5 minutes,the insulation is not breakdown.
Service conditions and operation parameters of Cable:
The cable is applied to fixed installation for rated voltage 0.6/1kV of power transportation and distribution line.
Max. rated temperature of conductor. nominal operating 90ºC
Short circuit: max. for 5 sec.250ºC
The cable can be laid without drop restriction, and the environment temperature shall not be lower than 0ºC.
IEC 60502-1
| No. of Cores and Nominal Cross Section |
Conductor Type | Nominal Insulation Thickness |
Nominal Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight | Max. D.C. Resistance of Conductor at 20ºC |
| No. × mm² | mm | mm | mm | kg/km | Ω/km | |
| 2×0.5 | 2 | 0.6 | 1.8 | 8.1 | 74 | 36 |
| 2×0.75 | 2 | 0.6 | 1.8 | 8.5 | 89 | 24.5 |
| 2×1 | 2 | 0.6 | 1.8 | 8.9 | 98 | 18.1 |
| 2×1.5 | 2 | 0.8 | 1.8 | 10.3 | 131 | 12.1 |
| 2×2.5 | 2 | 0.8 | 1.8 | 11.1 | 157 | 7.41 |
| 2×4 | 2 | 1 | 1.8 | 13 | 217 | 4.61 |
| 2×6 | 2 | 1 | 1.8 | 14.1 | 265 | 3.08 |
| 2×10 | 2 | 1 | 1.8 | 15.9 | 383 | 1.83 |
| 3×0.5 | 2 | 0.6 | 1.8 | 8.4 | 88 | 36 |
| 3×0.75 | 2 | 0.6 | 1.8 | 8.9 | 109 | 24.5 |
| 3×1 | 2 | 0.6 | 1.8 | 9.3 | 121 | 18.1 |
| 3×1.5 | 2 | 0.8 | 1.8 | 10.8 | 154 | 12.1 |
| 3×2.5 | 2 | 0.8 | 1.8 | 11.7 | 192 | 7.41 |
| 3×4 | 2 | 1 | 1.8 | 13.7 | 272 | 4.61 |
| 3×6 | 2 | 1 | 1.8 | 14.9 | 348 | 3.08 |
| 3×10 | 2 | 1 | 1.8 | 16.8 | 505 | 1.83 |
| 4×0.5 | 2 | 0.6 | 1.8 | 9 | 97 | 36 |
| 4×0.75 | 2 | 0.6 | 1.8 | 9.5 | 113 | 24.5 |
| 4×1 | 2 | 0.6 | 1.8 | 9.9 | 138 | 18.1 |
| 4×1.5 | 2 | 0.8 | 1.8 | 11.6 | 191 | 12.1 |
| 4×2.5 | 2 | 0.8 | 1.8 | 12.6 | 240 | 7.41 |
| 4×4 | 2 | 1 | 1.8 | 14.9 | 344 | 4.61 |
| 4×6 | 2 | 1 | 1.8 | 16.2 | 445 | 3.08 |
| 4×10 | 2 | 1 | 1.8 | 18.4 | 664 | 1.83 |
| 5×0.5 | 2 | 0.6 | 1.8 | 9.6 | 110 | 36 |
| 5×0.75 | 2 | 0.6 | 1.8 | 10.1 | 143 | 24.5 |
| 5×1 | 2 | 0.6 | 1.8 | 10.6 | 161 | 18.1 |
| 5×1.5 | 2 | 0.8 | 1.8 | 12.5 | 220 | 12.1 |
| 5×2.5 | 2 | 0.8 | 1.8 | 13.6 | 285 | 7.41 |
| 5×4 | 2 | 1 | 1.8 | 16.2 | 412 | 4.61 |
| 5×6 | 2 | 1 | 1.8 | 17.6 | 523 | 3.08 |
| 5×10 | 2 | 1 | 1.8 | 20.1 | 799 | 1.83 |
| No. of Cores and Nominal Cross Section |
Conductor Type | Nominal Insulation Thickness |
Nominal Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight | Max. D.C. Resistance of Conductor at 20ºC |
| No. × mm² | mm | mm | mm | kg/km | Ω/km | |
| 6×0.5 | 2 | 0.6 | 1.8 | 10.2 | 124 | 36 |
| 6×0.75 | 2 | 0.6 | 1.8 | 10.8 | 147 | 24.5 |
| 6×1 | 2 | 0.6 | 1.8 | 11.4 | 170 | 18.1 |
| 6×1.5 | 2 | 0.8 | 1.8 | 13.5 | 239 | 12.1 |
| 6×2.5 | 2 | 0.8 | 1.8 | 14.7 | 311 | 7.41 |
| 6×4 | 2 | 1 | 1.8 | 17.6 | 455 | 4.61 |
| 6×6 | 2 | 1 | 1.8 | 19.2 | 596 | 3.08 |
| 6×10 | 2 | 1 | 1.8 | 21.9 | 868 | 1.83 |
| 7×0.5 | 2 | 0.6 | 1.8 | 10.2 | 131 | 36 |
| 7×0.75 | 2 | 0.6 | 1.8 | 10.8 | 157 | 24.5 |
| 7×1 | 2 | 0.6 | 1.8 | 11.4 | 182 | 18.1 |
| 7×1.5 | 2 | 0.8 | 1.8 | 13.5 | 259 | 12.1 |
| 7×2.5 | 2 | 0.8 | 1.8 | 14.7 | 341 | 7.41 |
| 7×4 | 2 | 1 | 1.8 | 17.6 | 504 | 4.61 |
| 7×6 | 2 | 1 | 1.8 | 19.2 | 657 | 3.08 |
| 7×10 | 2 | 1 | 1.8 | 21.9 | 962 | 1.83 |
| 8×0.5 | 2 | 0.6 | 1.8 | 11.1 | 150 | 36 |
| 8×0.75 | 2 | 0.6 | 1.8 | 11.9 | 180 | 24.5 |
| 8×1 | 2 | 0.6 | 1.8 | 12.5 | 209 | 18.1 |
| 8×1.5 | 2 | 0.8 | 1.8 | 14.9 | 298 | 12.1 |
| 8×2.5 | 2 | 0.8 | 1.8 | 16.4 | 392 | 7.41 |
| 8×4 | 2 | 1 | 1.8 | 19.6 | 582 | 4.61 |
| 8×6 | 2 | 1 | 1.8 | 21.5 | 755 | 3.08 |
| 8×10 | 2 | 1 | 1.8 | 24.6 | 1111 | 1.83 |
| 9×0.5 | 2 | 0.6 | 1.8 | 11.9 | 167 | 36 |
| 9×0.75 | 2 | 0.6 | 1.8 | 12.7 | 203 | 24.5 |
| 9×1 | 2 | 0.6 | 1.8 | 13.4 | 235 | 18.1 |
| 9×1.5 | 2 | 0.8 | 1.8 | 16 | 334 | 12.1 |
| 9×2.5 | 2 | 0.8 | 1.8 | 17.6 | 442 | 7.41 |
| 9×4 | 2 | 1 | 1.8 | 21.2 | 655 | 4.61 |
| 9×6 | 2 | 1 | 1.8 | 23.2 | 857 | 3.08 |
| 9×10 | 2 | 1 | 1.8 | 26.7 | 1261 | 1.83 |
| No. of Cores and Nominal Cross Section |
Conductor Type | Nominal Insulation Thickness |
Nominal Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight | Max. D.C. Resistance of Conductor at 20ºC |
| No. × mm² | mm | mm | mm | kg/km | Ω/km | |
| 10×0.5 | 2 | 0.6 | 1.8 | 12.3 | 179 | 36 |
| 10×0.75 | 2 | 0.6 | 1.8 | 13.1 | 216 | 24.5 |
| 10×1 | 2 | 0.6 | 1.8 | 13.9 | 252 | 18.1 |
| 10×1.5 | 2 | 0.8 | 1.8 | 16.7 | 360 | 12.1 |
| 10×2.5 | 2 | 0.8 | 1.8 | 18.3 | 478 | 7.41 |
| 10×4 | 2 | 1 | 1.8 | 22.1 | 711 | 4.61 |
| 10×6 | 2 | 1 | 1.8 | 24.3 | 932 | 3.08 |
| 10×10 | 2 | 1 | 1.8 | 27.9 | 1369 | 1.83 |
| 12×0.5 | 2 | 0.6 | 1.8 | 12.6 | 195 | 36 |
| 12×0.75 | 2 | 0.6 | 1.8 | 13.5 | 238 | 24.5 |
| 12×1 | 2 | 0.6 | 1.8 | 14.3 | 280 | 18.1 |
| 12×1.5 | 2 | 0.8 | 1.8 | 17.2 | 406 | 12.1 |
| 12×2.5 | 2 | 0.8 | 1.8 | 18.9 | 543 | 7.41 |
| 12×4 | 2 | 1 | 1.8 | 22.8 | 816 | 4.61 |
| 12×6 | 2 | 1 | 1.8 | 25.1 | 1072 | 3.08 |
| 14×0.5 | 2 | 0.6 | 1.8 | 13.2 | 217 | 36 |
| 14×0.75 | 2 | 0.6 | 1.8 | 14.1 | 266 | 24.5 |
| 14×1 | 2 | 0.6 | 1.8 | 14.9 | 314 | 18.1 |
| 14×1.5 | 2 | 0.8 | 1.8 | 18 | 459 | 12.1 |
| 14×2.5 | 2 | 0.8 | 1.8 | 19.8 | 617 | 7.41 |
| 14×4 | 2 | 1 | 1.8 | 24 | 932 | 4.61 |
| 14×6 | 2 | 1 | 1.8 | 26.3 | 1230 | 3.08 |
| 16×0.5 | 2 | 0.6 | 1.8 | 13.8 | 242 | 36 |
| 16×0.75 | 2 | 0.6 | 1.8 | 14.8 | 298 | 24.5 |
| 16×1 | 2 | 0.6 | 1.8 | 15.6 | 352 | 18.1 |
| 16×1.5 | 2 | 0.8 | 1.8 | 18.9 | 516 | 12.1 |
| 16×2.5 | 2 | 0.8 | 1.8 | 20.9 | 696 | 7.41 |
| 16×4 | 2 | 1 | 1.8 | 25.3 | 1055 | 4.61 |
| 16×6 | 2 | 1 | 1.8 | 27.8 | 1393 | 3.08 |
| 19×0.5 | 2 | 0.6 | 1.8 | 14.4 | 271 | 36 |
| 19×0.75 | 2 | 0.6 | 1.8 | 15.5 | 336 | 24.5 |
| 19×1 | 2 | 0.6 | 1.8 | 16.4 | 400 | 18.1 |
| 19×1.5 | 2 | 0.8 | 1.8 | 19.9 | 592 | 12.1 |
| 19×2.5 | 2 | 0.8 | 1.8 | 22 | 802 | 7.41 |
| 19×4 | 2 | 1 | 1.8 | 26.7 | 1222 | 4.61 |
| 19×6 | 2 | 1 | 1.9 | 29.9 | 1643 | 3.08 |
| No. of Cores and Nominal Cross Section |
Conductor Type | Nominal Insulation Thickness |
Nominal Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight | Max. D.C. Resistance of Conductor at 20ºC |
| No. × mm² | mm | mm | mm | kg/km | Ω/km | |
| 20×0.5 | 2 | 0.6 | 1.8 | 15.1 | 286 | 36 |
| 20×0.75 | 2 | 0.6 | 1.8 | 16.2 | 355 | 24.5 |
| 20×1 | 2 | 0.6 | 1.8 | 17.2 | 422 | 18.1 |
| 20×1.5 | 2 | 0.8 | 1.8 | 20.9 | 624 | 12.1 |
| 20×2.5 | 2 | 0.8 | 1.8 | 23.1 | 845 | 7.41 |
| 20×4 | 2 | 1 | 1.8 | 28.2 | 1288 | 4.61 |
| 20×6 | 2 | 1 | 1.9 | 31.5 | 1731 | 3.08 |
| 21×0.5 | 2 | 0.6 | 1.8 | 15.1 | 294 | 36 |
| 21×0.75 | 2 | 0.6 | 1.8 | 16.2 | 366 | 24.5 |
| 21×1 | 2 | 0.6 | 1.8 | 17.2 | 436 | 18.1 |
| 21×1.5 | 2 | 0.8 | 1.8 | 20.9 | 647 | 12.1 |
| 21×2.5 | 2 | 0.8 | 1.8 | 23.1 | 879 | 7.41 |
| 21×4 | 2 | 1 | 1.8 | 28.2 | 1342 | 4.61 |
| 21×6 | 2 | 1 | 1.9 | 31.5 | 1804 | 3.08 |
| 22×0.5 | 2 | 0.6 | 1.8 | 15.8 | 309 | 36 |
| 22×0.75 | 2 | 0.6 | 1.8 | 17 | 385 | 24.5 |
| 22×1 | 2 | 0.6 | 1.8 | 18 | 458 | 18.1 |
| 22×1.5 | 2 | 0.8 | 1.8 | 22 | 679 | 12.1 |
| 22×2.5 | 2 | 0.8 | 1.8 | 24.4 | 922 | 7.41 |
| 22×4 | 2 | 1 | 1.9 | 30.2 | 1430 | 4.61 |
| 22×6 | 2 | 1 | 2 | 33.5 | 1908 | 3.08 |
| 24×0.5 | 2 | 0.6 | 1.8 | 16.5 | 338 | 36 |
| 24×0.75 | 2 | 0.6 | 1.8 | 17.8 | 420 | 24.5 |
| 24×1 | 2 | 0.6 | 1.8 | 18.8 | 500 | 18.1 |
| 24×1.5 | 2 | 0.8 | 1.8 | 23 | 739 | 12.1 |
| 24×2.5 | 2 | 0.8 | 1.8 | 25.6 | 1006 | 7.41 |
| 24×4 | 2 | 1 | 1.9 | 31.7 | 1559 | 4.61 |
| 24×6 | 2 | 1 | 2 | 35.1 | 2084 | 3.08 |
| 27×0.5 | 2 | 0.6 | 1.8 | 16.8 | 362 | 36 |
| 27×0.75 | 2 | 0.6 | 1.8 | 18.1 | 453 | 24.5 |
| 27×1 | 2 | 0.6 | 1.8 | 19.2 | 542 | 18.1 |
| 27×1.5 | 2 | 0.8 | 1.8 | 23.5 | 808 | 12.1 |
| 27×2.5 | 2 | 0.8 | 1.8 | 26.1 | 1104 | 7.41 |
| 27×4 | 2 | 1 | 2 | 32.6 | 1732 | 4.61 |
| 27×6 | 2 | 1 | 2.1 | 36.1 | 2314 | 3.08 |
| 30×0.5 | 2 | 0.6 | 1.8 | 17.4 | 392 | 36 |
| 30×0.75 | 2 | 0.6 | 1.8 | 18.7 | 493 | 24.5 |
| 30×1 | 2 | 0.6 | 1.8 | 19.9 | 592 | 18.1 |
| 30×1.5 | 2 | 0.8 | 1.8 | 24.3 | 885 | 12.1 |
| 30×2.5 | 2 | 0.8 | 1.8 | 27 | 1212 | 7.41 |
| 30×4 | 2 | 1 | 2 | 33.8 | 1903 | 4.61 |
| 30×6 | 2 | 1 | 2.1 | 37.4 | 2547 | 3.08 |



About the Supplier
This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASI259471". Items marked "" are certified.
Company Profile
Henan Xunda Cable Co., Ltd., established in 2001, is a manufacturer specializing in the R&D and production of high-quality wires and cables. With over 20 years of experience, we provide reliable cable solutions, strengthened by our subsidiary, Xina Cable, for global reach and better service.
We produce a wide range of cables, including AAC, AAAC, ACSR, Power Cables (up to 35KV), Control Cables, Concentric Cables, Solar Cables, Building Wires, Nylon Wires, LSOH wires, and Branch Cables. Our products are widely used in power transmission, petrochemicals, metallurgy, construction, and infrastructure projects.
Located in the Industrial Zone of Gongyi, Zhengzhou City, Henan, China, our 30, 000m2 factory employs over 100 staff, including 20 senior technicians. With 30+ advanced production lines including high-speed drawing, stranding, and extrusion equipment, our daily bare conductor production capacity achieves more than 100 tons. Our strict quality control system and full-scale testing equipment ensure all products comply with ISO9001, CCC, and international standards, ensuring safety, durability, and reliability.
We have exported to over 20 countries, including Chile, Dominica, Panama, Colombia, Nicaragua, Peru, Philippines, Vietnam, Malaysia, Australia, PNG, Burundi, Tanzania, Madagascar, Angola among others. We provide 48-hour technical support, flexible payments, and efficient logistics for smooth transactions and timely delivery.
Our mission: Transmit Light, Connect World, Create Win-win, Grow together!
About Our Factory & Business Background
- Address
- Industrial Zone of Gongyi, Zhengzhou City, Henan, China
- Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
- International Commercial Terms(Incoterms)
- FOB, CFR, CIF
- Average Lead Time
-
Peak Season Lead Time: 1-3 months
Off Season Lead Time: one month - Nearest Port
- QINGDAO, TIANJIN, SHANGHAI
Our Production Capability & Technical Expertise
- Main Products
- AAC AAAC ACSR Power Cables (up to 35kv) Cont
-
Production Lines
- 27
-
Production Machines
- Annealing furnace, Wire drawing machine, Stranding machine, Armored machine, Cabling machine, Extrusion machine
-
QA/QC inspectors
- 5 people
-
Inspection Type for Finished Products
- 100% inspection(Visual inspection & Function inspection)
-
Inspection Method for Finished Products
- Have instructions and uniformly followed
-
Customization Options
- Customization from Designs, Full Customization
-
ODM Service Available
- Yes
-
OEM Service Available
- Yes
-
R&D Engineers
- 5 people
-
Traceability of Raw Materials
- Yes
Our Industry Experience & Global Business Record
- Export Year
- 2025-04-14
- Main Markets
- North America, South America, Eastern Europe, Southeast Asia
-
New Products Launched in Last year
- No
FAQ
- Are you a factory or trading company
- We are a factory based in Henan, China, with more than150 workers
- How can I visit there?
- If you need, we will arange a driver to pick you up
- How can I get some samples?
- Contact me on below, Determine sample and address for shipping
- Have you ever supplied cables to our country?
- We have been sold to over 30 countries and regions in the world. You can contact me for details
- What's your MOQ?
- It is normally 1km for insulated cables and 1 ton for bare conductor.
- When can I get the price?
- Usually quote within 3 hours after we get your inquiry
- How long is your delivery time?
- According to your order's quantity. Usuall your lead time is 3-20 working days
Send your message to this supplier
People who viewed this also viewed
-
US$1.89-33.37 / Meter
-
US$0.20-2.99 / Meter
-
US$0.30-0.78 / Meter
-
US$1.50 / Piece
-
US$0.12-0.90 / Meter
-
US$0.20-6.99 / Meter
-
US$4.20 / Meter
-
US$0.50-3.00 / kg
Find Similar Products By Category
- Supplier Homepage
- Products
- Control Cable
- Flexible Copper Conductor Multicore PVC Insulated Control Cable for Automation
Related Categories
Hot Searches
- China Cable Factories
- Control Cable Factories
- Wire Cable Factories
- PVC Cable Factories
- Copper Pvc Cable
- Pvc Copper Wire Cable
- Copper Insulated Wire Cable
- Copper Control Cable
- Flexible Wire Cable
- Top 10 Cable
- Cable Trends
- Flexible Control Cable Bulkbuy