Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems

Product Details
Customization: Available
Type: Insulated
Conductor Type: Stranded
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 30 days
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
CCC
to see all verified strength labels (22)
  • Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems
  • Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems
  • Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems
  • Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems
  • Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems
  • Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems
Find Similar Products

Basic Info.

Model NO.
KVV
Application
Overhead
Conductor Material
Copper
Sheath Material
PVC
Insulation Material
PVC
Material Shape
Round Wire
Range of Application
LSOH
Certification
ISO9001, CE, CCC
Brand
Xunda
Rated Voltage
600/1000V
Rated Temperature
80/105 ºC
Resisitivity
Less Than 17.24 NΩ·m
Voltage Test
Yes
Ampacity
8A/mm2
Core
Muticore
Standard
IEC 60228, IEC 60502-1
Insulation Thickness
0.6-1mm
Sheath Thickness
1.8-2.1
MOQ
1000m
ODM Available
Yes
Color
Customized
Package Length
Customized
Third Party Inspection
Available
Environment Friendly
Yes
Transport Package
Drum/Tray
Specification
0.5-10mm2
Trademark
XUNDA
Origin
China
HS Code
8544492900
Production Capacity
100km/Month

Packaging & Delivery

Package Size
100.00cm * 100.00cm * 100.00cm
Package Gross Weight
1000.000kg

Product Description

Product Details
Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems
Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems
 

 

Application
Good electrical and mechanical properties. Resistance to abrasion, moisture and sunlight. Adequate resistance to oil and abrasion.
This product is applicable to AC rated voltage U0/U is the control cable for fixed laying in control, monitoring circuit and protection circuit of (U0/U) 0.6/1kV and below.


 
Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems
Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems
 

 

CONSTRUCTION
Conductor: Conductor: Copper, class 1, 2, or 5, solid, stranded round or soft conductor

Insulation: Polyvinyl chloride PVC

Filler: Non-hygroscopic material

Binder: Non-hygroscopic material

Outer sheath: Polyvinyl chloride PV

 

Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems

SPECIFICATION

IEC 60228 Conductors of Insulate Cables

IEC 60502-1 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1kV(Um=1.2kV) up to 30kV(Um=36kV) - Part 1: Cables for Rated Voltages of 1kV (Um=1.2kV) and 3kV(Um=3.6kV)

IEC 60502-1

  
No. of Cores and
Nominal Cross Section
Conductor Type Nominal Insulation
Thickness 
Nominal Sheath
Thickness
Approx. Overall
Diameter
Approx. Weight Max. D.C. Resistance 
of Conductor at 20ºC 
No. × mm²   mm mm mm kg/km Ω/km
2×0.5 2 0.6 1.8 8.1 74 36
2×0.75 2 0.6 1.8 8.5 89 24.5
2×1 2 0.6 1.8 8.9 98 18.1
2×1.5 2 0.8 1.8 10.3 131 12.1
2×2.5 2 0.8 1.8 11.1 157 7.41
2×4 2 1 1.8 13 217 4.61
2×6 2 1 1.8 14.1 265 3.08
2×10 2 1 1.8 15.9 383 1.83
3×0.5 2 0.6 1.8 8.4 88 36
3×0.75 2 0.6 1.8 8.9 109 24.5
3×1 2 0.6 1.8 9.3 121 18.1
3×1.5 2 0.8 1.8 10.8 154 12.1
3×2.5 2 0.8 1.8 11.7 192 7.41
3×4 2 1 1.8 13.7 272 4.61
3×6 2 1 1.8 14.9 348 3.08
3×10 2 1 1.8 16.8 505 1.83
4×0.5 2 0.6 1.8 9 97 36
4×0.75 2 0.6 1.8 9.5 113 24.5
4×1 2 0.6 1.8 9.9 138 18.1
4×1.5 2 0.8 1.8 11.6 191 12.1
4×2.5 2 0.8 1.8 12.6 240 7.41
4×4 2 1 1.8 14.9 344 4.61
4×6 2 1 1.8 16.2 445 3.08
4×10 2 1 1.8 18.4 664 1.83
5×0.5 2 0.6 1.8 9.6 110 36
5×0.75 2 0.6 1.8 10.1 143 24.5
5×1 2 0.6 1.8 10.6 161 18.1
5×1.5 2 0.8 1.8 12.5 220 12.1
5×2.5 2 0.8 1.8 13.6 285 7.41
5×4 2 1 1.8 16.2 412 4.61
5×6 2 1 1.8 17.6 523 3.08
5×10 2 1 1.8 20.1 799 1.83
No. of Cores
and Nominal
Cross Section
Conductor Type Nominal Insulation
Thickness 
Nominal Sheath
Thickness
Approx. Overall
Diameter
Approx. Weight Max. D.C. Resistance of
Conductor at 20ºC 
No. × mm²   mm mm mm kg/km Ω/km
6×0.5 2 0.6 1.8 10.2 124 36
6×0.75 2 0.6 1.8 10.8 147 24.5
6×1 2 0.6 1.8 11.4 170 18.1
6×1.5 2 0.8 1.8 13.5 239 12.1
6×2.5 2 0.8 1.8 14.7 311 7.41
6×4 2 1 1.8 17.6 455 4.61
6×6 2 1 1.8 19.2 596 3.08
6×10 2 1 1.8 21.9 868 1.83
7×0.5 2 0.6 1.8 10.2 131 36
7×0.75 2 0.6 1.8 10.8 157 24.5
7×1 2 0.6 1.8 11.4 182 18.1
7×1.5 2 0.8 1.8 13.5 259 12.1
7×2.5 2 0.8 1.8 14.7 341 7.41
7×4 2 1 1.8 17.6 504 4.61
7×6 2 1 1.8 19.2 657 3.08
7×10 2 1 1.8 21.9 962 1.83
8×0.5 2 0.6 1.8 11.1 150 36
8×0.75 2 0.6 1.8 11.9 180 24.5
8×1 2 0.6 1.8 12.5 209 18.1
8×1.5 2 0.8 1.8 14.9 298 12.1
8×2.5 2 0.8 1.8 16.4 392 7.41
8×4 2 1 1.8 19.6 582 4.61
8×6 2 1 1.8 21.5 755 3.08
8×10 2 1 1.8 24.6 1111 1.83
9×0.5 2 0.6 1.8 11.9 167 36
9×0.75 2 0.6 1.8 12.7 203 24.5
9×1 2 0.6 1.8 13.4 235 18.1
9×1.5 2 0.8 1.8 16 334 12.1
9×2.5 2 0.8 1.8 17.6 442 7.41
9×4 2 1 1.8 21.2 655 4.61
9×6 2 1 1.8 23.2 857 3.08
9×10 2 1 1.8 26.7 1261 1.83
             
 
No. of Cores
and Nominal
Cross Section
Conductor Type Nominal Insulation
Thickness 
Nominal Sheath
Thickness
Approx. Overall
Diameter
Approx. Weight Max. D.C. Resistance of
Conductor at 20ºC 
No. × mm²   mm mm mm kg/km Ω/km
10×0.5 2 0.6 1.8 12.3 179 36
10×0.75 2 0.6 1.8 13.1 216 24.5
10×1 2 0.6 1.8 13.9 252 18.1
10×1.5 2 0.8 1.8 16.7 360 12.1
10×2.5 2 0.8 1.8 18.3 478 7.41
10×4 2 1 1.8 22.1 711 4.61
10×6 2 1 1.8 24.3 932 3.08
10×10 2 1 1.8 27.9 1369 1.83
12×0.5 2 0.6 1.8 12.6 195 36
12×0.75 2 0.6 1.8 13.5 238 24.5
12×1 2 0.6 1.8 14.3 280 18.1
12×1.5 2 0.8 1.8 17.2 406 12.1
12×2.5 2 0.8 1.8 18.9 543 7.41
12×4 2 1 1.8 22.8 816 4.61
12×6 2 1 1.8 25.1 1072 3.08
14×0.5 2 0.6 1.8 13.2 217 36
14×0.75 2 0.6 1.8 14.1 266 24.5
14×1 2 0.6 1.8 14.9 314 18.1
14×1.5 2 0.8 1.8 18 459 12.1
14×2.5 2 0.8 1.8 19.8 617 7.41
14×4 2 1 1.8 24 932 4.61
14×6 2 1 1.8 26.3 1230 3.08
16×0.5 2 0.6 1.8 13.8 242 36
16×0.75 2 0.6 1.8 14.8 298 24.5
16×1 2 0.6 1.8 15.6 352 18.1
16×1.5 2 0.8 1.8 18.9 516 12.1
16×2.5 2 0.8 1.8 20.9 696 7.41
16×4 2 1 1.8 25.3 1055 4.61
16×6 2 1 1.8 27.8 1393 3.08
19×0.5 2 0.6 1.8 14.4 271 36
19×0.75 2 0.6 1.8 15.5 336 24.5
19×1 2 0.6 1.8 16.4 400 18.1
19×1.5 2 0.8 1.8 19.9 592 12.1
19×2.5 2 0.8 1.8 22 802 7.41
19×4 2 1 1.8 26.7 1222 4.61
19×6 2 1 1.9 29.9 1643 3.08
             
No. of Cores
and Nominal
Cross Section
Conductor Type Nominal Insulation
Thickness 
Nominal Sheath
Thickness
Approx. Overall
Diameter
Approx. Weight Max. D.C. Resistance
of Conductor at 20ºC 
No. × mm²   mm mm mm kg/km Ω/km
20×0.5 2 0.6 1.8 15.1 286 36
20×0.75 2 0.6 1.8 16.2 355 24.5
20×1 2 0.6 1.8 17.2 422 18.1
20×1.5 2 0.8 1.8 20.9 624 12.1
20×2.5 2 0.8 1.8 23.1 845 7.41
20×4 2 1 1.8 28.2 1288 4.61
20×6 2 1 1.9 31.5 1731 3.08
21×0.5 2 0.6 1.8 15.1 294 36
21×0.75 2 0.6 1.8 16.2 366 24.5
21×1 2 0.6 1.8 17.2 436 18.1
21×1.5 2 0.8 1.8 20.9 647 12.1
21×2.5 2 0.8 1.8 23.1 879 7.41
21×4 2 1 1.8 28.2 1342 4.61
21×6 2 1 1.9 31.5 1804 3.08
22×0.5 2 0.6 1.8 15.8 309 36
22×0.75 2 0.6 1.8 17 385 24.5
22×1 2 0.6 1.8 18 458 18.1
22×1.5 2 0.8 1.8 22 679 12.1
22×2.5 2 0.8 1.8 24.4 922 7.41
22×4 2 1 1.9 30.2 1430 4.61
22×6 2 1 2 33.5 1908 3.08
24×0.5 2 0.6 1.8 16.5 338 36
24×0.75 2 0.6 1.8 17.8 420 24.5
24×1 2 0.6 1.8 18.8 500 18.1
24×1.5 2 0.8 1.8 23 739 12.1
24×2.5 2 0.8 1.8 25.6 1006 7.41
24×4 2 1 1.9 31.7 1559 4.61
24×6 2 1 2 35.1 2084 3.08
27×0.5 2 0.6 1.8 16.8 362 36
27×0.75 2 0.6 1.8 18.1 453 24.5
27×1 2 0.6 1.8 19.2 542 18.1
27×1.5 2 0.8 1.8 23.5 808 12.1
27×2.5 2 0.8 1.8 26.1 1104 7.41
27×4 2 1 2 32.6 1732 4.61
27×6 2 1 2.1 36.1 2314 3.08
30×0.5 2 0.6 1.8 17.4 392 36
30×0.75 2 0.6 1.8 18.7 493 24.5
30×1 2 0.6 1.8 19.9 592 18.1
30×1.5 2 0.8 1.8 24.3 885 12.1
30×2.5 2 0.8 1.8 27 1212 7.41
30×4 2 1 2 33.8 1903 4.61
30×6 2 1 2.1 37.4 2547 3.08
             
 
Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems
Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems





Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems
Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems
Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems
Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems
Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems

Flexible Multi-Core Kvv Control Cable for Industrial Automation Control SystemsFlexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems

Flexible Multi-Core Kvv Control Cable for Industrial Automation Control SystemsFlexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems

Flexible Multi-Core Kvv Control Cable for Industrial Automation Control Systems
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier