Premium Overhead Bare Conductors AAC/AAAC ACSR for Efficient Power Transmission

Product Details
Customization: Available
Application: Construction, Overhead, Underground, Industrial, Power Station, Telecommunication, Computer, Car
Voltage: Low and Medium Voltage Cable
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 30 days
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
CCC
to see all verified strength labels (22)
  • Premium Overhead Bare Conductors AAC/AAAC ACSR for Efficient Power Transmission
  • Premium Overhead Bare Conductors AAC/AAAC ACSR for Efficient Power Transmission
  • Premium Overhead Bare Conductors AAC/AAAC ACSR for Efficient Power Transmission
  • Premium Overhead Bare Conductors AAC/AAAC ACSR for Efficient Power Transmission
  • Premium Overhead Bare Conductors AAC/AAAC ACSR for Efficient Power Transmission
  • Premium Overhead Bare Conductors AAC/AAAC ACSR for Efficient Power Transmission
Find Similar Products

Basic Info.

Model NO.
ACSR / AAC /AAAC / BCC / ACAR
Current
DC & AC
Insulation Material
Bare
Sheath Material
Bare
Material Shape
Round Wire
Wire Core Material
Steel
Certification
ISO, CCC, CE, RoHS, VDE
Model
AGRP
Brand
Xunda Cable
Range of Application
Construction, Overhead, Underground, Industrial, P
Color
Silvery White
Quality
100% Test It
Transport Package
Wooden Drum, Steel Drum, Steel&Wooden Drum, Pallet
Specification
BS215
Trademark
Xunda Cable
Origin
Henan
HS Code
7614900000
Production Capacity
5000 Tons/Month

Product Description

ACSR / AAC /AAAC / BCC / ACAR Overhead Bare Conductors
Application
Overhead lines, sometimes referred to as aerial conductors, are often specified where there are significant distances to cover and where these cables are best positioned far out of reach. The distances to cover, the environmental conditions it will face, and the location are all factors in specifying the appropriate cable. The main classifications of bare conductor are AAC (All aluminum conductor), AAAC (All aluminum Alloy Conductor) or ACSR (aluminum conductor steel reinforced). AAC is most commonly found in urban areas with frequent supports and short spans. It is also used in coastal regions where salt in the air can cause corrosion - the all aluminum wire providing corrosion resistance - and specified for use in the railway industry for OHL electrification. AAAC tend to be specified where greater mechanical resistance is required and where there is a reduced sag characteristic. The ACSR, with its steel reinforcement provides additional strength and where the spans run for larger distances, such as across rivers. The advantages of AAC, AAAC and ACSR come in their lightweight properties. These overhead lines have no specified voltage rating - it will depend on the type of installation - although the higher corona limit of ACSR makes it beneficial when used with high voltage and extra-high voltage transmission. The overhead line wires are manufactured in accordance with various national standards and can be sized appropriately - including GB/T1179 ASTM B231, ASTM B399, IEC 61089, DIN 48201, BS 215, BS 3242, BS EN 50182 and Spanish standard UNE 21.018. etc.

Standards
GB/T1179, IEC61089, ASTM B231, ASTM B399, BS215-1, BS3242, DIN48201, BS EN 50182 etc.

Bare conductor recommendations

Type Description
AAC All Aluminum Conductor
ACSR Aluminum Conductor Steel Reinforced
AAAC All aluminum Alloy Conductor
ACAR Aluminum Conductor Alloy Reinforced
AACSR All Aluminum Alloy Conductor Steel Reinforced
ACSR / AW Aluminum Conductor Aluminum Clad Steel Reinforced
TACSR Thermal Resistant Aluminum-alloy Conductor Steel Reinforced
ACSS Aluminum Conductor Steel Supported
ACSS/AW Aluminum Conductor. Aluminum-Clad Steel Supported
ACSS/TS Aluminum Conductor, Steel Supported. Trapezoidal Shaped
ACS Aluminum Clad Steel
CCS Copper Clad Steel
GSW Galvanized Steel Wire


AAC-All Aluminum Conductor

Premium Overhead Bare Conductors AAC/AAAC ACSR for Efficient Power Transmission


DESCRIPTION
AAC-All aluminum Conductors has the characteristics of simple structure, convenient erection and maintenance, low cost, large transmission capacity, good conductivity, sufficient mechanical strength and high tensile strength. Concentric lay stranded Aluminium Conductors (AAC) are made out of Hard-Drawn aluminum wires. 

APPLICATION
AAC is used mainly in urban areas where the spacing is short and the supports are close. All aluminium conductors are made up of one or more strands of aluminium wire depending on the end usage. AAC is also used extensively in coastal regions because it has a high degree of corrosion resistance.
Premium Overhead Bare Conductors AAC/AAAC ACSR for Efficient Power Transmission
STANDARDS
IEC 61089
ASTM B 231
BS EN 50182
AS 1531
GB/T 1179



AAAC -All Aluminum Alloy Conductor

APPLICATION
AAAC is used as a bare overhead conductor for power transmission and distribution lines, on aerial circuits that require a larger mechanical resistance than AAC, and a better corrosion resistance than ACSR. The sag characteristics and the strength-to-weight ratio of AAAC is better than both AAC / ACSR.

DESCRIPTION 
Concentric lay stranded Aluminium Alloy Conductors (AAAC) are made out of high strength Aluminium-Magnesium-Silicon Alloy.

STANDARDS
IEC 61089
ASTM B 399
BS EN 50182
AS 1531
GB/T 1179



ACSR -Aluminum Conductor Steel Reinforced
Premium Overhead Bare Conductors AAC/AAAC ACSR for Efficient Power Transmission

APPLICATION
Used as bare overhead transmission conductor and as primary and secondary distribution conductor and messenger support. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. 

DESCRIPTION 
Aluminium Conductor Steel Reinforced (ACSR) is concentrically stranded conductor with one or more layers of hard drawn aluminium wire on galvanized steel wire core. The core can be single wire or stranded depending on the size. Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease.

STANDARDS
IEC 61089
ASTM B 232
BS EN 50182
AS 3607
GB/T 1179



AAC & AAAC & ACSR
Dimension AAC
 (All Aluminum Conductor)
AAAC
(All Aluminum Alloy Conductor)
ACSR
(Aluminum Conductor Steel Reinforced)
Product Name & Code AAC 1350-H19 AAAC 6201-T81 ACSR 26/7 (Customizable Steel Core Ratio)
Material Composition 99.6% Pure Aluminum Strands Aluminum-Magnesium-Silicon Alloy Aluminum Layers + Galvanized Steel Core
Appearance Smooth Silver Surface, No Coating Slightly Denser Texture, Natural Metallic Shine Visible Steel Core in Cross-Section, Dual-Tone
Key Standards ASTM B230, IEC 61089 ASTM B399, BS EN 50183 ASTM B232, IEC 61089, BS 215
Certifications ISO 9001, CE, RoHS ISO 9001, CE, RoHS, DNV-GL (Marine) ISO 9001, CE, UL, IECEx (Hazardous Areas)
Conductivity 61% IACS (Highest) 53-56% IACS Depends on Aluminum Area (Steel Non-Conductive)
Tensile Strength 150-170 MPa 250-300 MPa 300-600 MPa (Adjustable via Steel Core Ratio)
Corrosion Resistance Good (Al Oxide Layer) Excellent (Alloy Inhibits Oxidation) Moderate (Galvanized Steel Required)
Typical Applications - Rural Grids - Coastal Power Lines - EHV Transmission (≥132kV)
- Short Span LV Distribution - Industrial Zones - Mountain Crossings
Temperature Range -20°C to +80°C -30°C to +90°C -40°C to +120°C
Cost Efficiency Lowest Initial Cost Moderate (Balanced Performance) Higher Initial Cost, Lower Lifetime Cost
Packaging & Shipping Wooden Drums, Anti-Moisture Film Coiled on Steel Reels, Waterproof Wrap Custom Lengths (≤3km/Reel), Corrosion-Resistant Coating
 
 
 
Premium Overhead Bare Conductors AAC/AAAC ACSR for Efficient Power Transmission
Industry Solutions
Power grid
New energy
Building
Industry
Marine cable
Telecommunication
Railway
Instrument


Our Certificate
Premium Overhead Bare Conductors AAC/AAAC ACSR for Efficient Power Transmission
Company Information


Premium Overhead Bare Conductors AAC/AAAC ACSR for Efficient Power TransmissionPremium Overhead Bare Conductors AAC/AAAC ACSR for Efficient Power TransmissionPremium Overhead Bare Conductors AAC/AAAC ACSR for Efficient Power TransmissionPremium Overhead Bare Conductors AAC/AAAC ACSR for Efficient Power Transmission
FAQ

1. Q:Are you a factory or trading company?
A: Manufacturing base in Henan ,China, with more than 150 workers.

2. Q:How can I visit there?
A: Sure,lf you need,we will arrange the driver to pick you up.

3. Q:How can I get some samples?
A: Contact me on below,Determine sample and address for shipping.

4. Q:Have you ever supplied cables to our country?
A: Xunda Cable have been sold to over 30 countries and regions in the world. you cancontact me for details.

5. Q:What is your MOQ?
A: MOQ Normally 1km for insulated cables(1 ton for bare conductor).Please contact mefor detail info if you have specific cable requirement.

6. Q:When can l get the price?
A: Usually quote within 3hours after we get your inquiry.

7. Q:How long is your delivery time?
A: According to your order's quantity.Usually our lead time is 3 - 20 working days.