Low Voltage 1 2 3 4 Core 1/0, 2/0, 3/0, 4/0AWG, 266.8/300/336.4Kcmil Aluminium Aerial Bundled Overhead Power Cable
Phase Conductor : AAC
Neutral Conductor : AAC/AAAC
Insulation : XLPE/PE
Rated Voltage : 0.6/1KV
Cores: Available in variants of 1, 2, 3, 4, 5, 2+1, 3+1, 3+2, 4+1, 4+2 Cores to suit your needs
Other Standards: Conforming to ASTM/ BS 7870-5/ IEC 60502/AS/NZS standards or customized to your specifications.
Application: These expertly engineered aerial bundled cables are crafted for overhead distribution lines with all conductors made of durable aluminium.
Insulated with XLPE, the phase and neutral cores are meticulously laid up in a bundle with a left-hand lay. Perfect for fixed installations as overhead power lines up to 1000V, offering unrivaled reliability. They can also supply 120/220V aerial service, ideal for temporary setups at construction sites, or act as service drops (from power pole to service entrance), as secondary cables (pole to pole), or for street lighting.
Designed for service at 600V or lower with a maximum conductor temperature of 75ºC for polyethylene insulated cables or 90ºC for XLPE insulation, ensuring optimal performance across varying conditions.
NFC 33-209
AAC/XLPE
No. of Cores and Section |
No. of Wires |
Nominal Insulation Thickness |
Approx. Diameter |
Max. DC. Resistance at 20ºC |
Approx. Weight |
of Cable |
mm2 |
No. |
mm |
mm |
Ω/km |
kg/km |
2x16 |
7 |
1.2 |
14.4 |
1.91 |
131 |
2x25 |
7 |
1.4 |
17.6 |
1.2 |
200 |
2x35 |
7 |
1.6 |
20.4 |
0.868 |
273 |
2x50 |
7 |
1.6 |
22.6 |
0.641 |
350 |
2x70 |
12 |
1.8 |
26.8 |
0.443 |
495 |
2x95 |
19 |
1.8 |
30.4 |
0.32 |
656 |
2x120 |
19 |
1.8 |
32.8 |
0.253 |
799 |
4x16 |
7 |
1.2 |
17.4 |
1.91 |
262 |
4x25 |
7 |
1.4 |
21.3 |
1.2 |
399 |
4x35 |
7 |
1.6 |
24.7 |
0.868 |
547 |
4x50 |
7 |
1.6 |
27.3 |
0.641 |
699 |
4x70 |
12 |
1.8 |
32.4 |
0.443 |
990 |
4x95 |
19 |
1.8 |
36.8 |
0.32 |
1311 |
4x120 |
19 |
1.8 |
39.7 |
0.253 |
1597 |
AAC/XLPE+AAAC/XLPE
No. of Cores and Section |
No. of Wires |
Nominal Insulation Thickness |
Approx. Diameter |
Max. DC. Resistance at 20ºC |
Approx. Weight |
Phase |
Neutral |
Phase |
Neutral |
of Cable |
Phase |
Neutral |
mm2 |
No. |
No. |
mm |
mm |
mm |
Ω/km |
Ω/km |
kg/km |
1x25+1x54.6 |
7 |
7 |
1.4 |
1.6 |
21.3 |
1.2 |
0.63 |
309 |
1x35+1x54.6 |
7 |
7 |
1.6 |
1.6 |
22.7 |
0.868 |
0.63 |
345 |
1x50+1x54.6 |
7 |
7 |
1.6 |
1.6 |
23.8 |
0.641 |
0.63 |
384 |
1x70+1x54.6 |
12 |
7 |
1.8 |
1.6 |
25.9 |
0.443 |
0.63 |
456 |
1x95+1x54.6 |
19 |
7 |
1.8 |
1.6 |
27.7 |
0.32 |
0.63 |
537 |
1x70+1x70 |
12 |
7 |
1.8 |
1.6 |
26.7 |
0.443 |
0.5 |
491 |
1x95+1x70 |
19 |
7 |
1.8 |
1.6 |
28.5 |
0.32 |
0.5 |
571 |
1x120+1x70 |
19 |
7 |
1.8 |
1.6 |
29.7 |
0.253 |
0.5 |
643 |
1x120+1x95 |
19 |
19 |
1.8 |
1.6 |
31.9 |
0.253 |
0.343 |
737 |
1x150+1x95 |
19 |
19 |
1.8 |
1.6 |
33.6 |
0.206 |
0.343 |
819 |
3x25+1x54.6 |
7 |
7 |
1.4 |
1.6 |
23.5 |
1.2 |
0.63 |
508 |
3x35+1x54.6 |
7 |
7 |
1.6 |
1.6 |
26.1 |
0.868 |
0.63 |
619 |
3x50+1x54.6 |
7 |
7 |
1.6 |
1.6 |
28.1 |
0.641 |
0.63 |
733 |
3x70+1x54.6 |
12 |
7 |
1.8 |
1.6 |
31.9 |
0.443 |
0.63 |
951 |
3x95+1x54.6 |
19 |
7 |
1.8 |
1.6 |
35.2 |
0.32 |
0.63 |
1192 |
3x70+1x70 |
12 |
7 |
1.8 |
1.6 |
32.4 |
0.443 |
0.5 |
986 |
3x95+1x70 |
19 |
7 |
1.8 |
1.6 |
35.6 |
0.32 |
0.5 |
1227 |
3x120+1x70 |
19 |
7 |
1.8 |
1.6 |
37.8 |
0.253 |
0.5 |
1441 |
3x120+1x95 |
19 |
19 |
1.8 |
1.6 |
39.1 |
0.253 |
0.343 |
1536 |
3x150+1x95 |
19 |
19 |
1.8 |
1.6 |
42.2 |
0.206 |
0.343 |
1779 |
BS 6485,BS 7884
AAC/XLPE
Number of Cores and Size |
Min. No. of Wires |
Nominal Insulation Thickness |
Approx. Diameter of Cable |
Max. DC. Resistance at 20ºC |
Breaking Load |
Approx .weight |
mm2 |
No. |
mm |
mm |
Ω/km |
kN |
kg/km |
1x10 |
6 |
1 |
5.8 |
3.08 |
1.65 |
41 |
1x16 |
6 |
1.2 |
7.2 |
1.91 |
2.517 |
65 |
1x25 |
6 |
1.2 |
8.4 |
1.2 |
3.762 |
94 |
1x35 |
6 |
1.4 |
9.8 |
0.868 |
5.177 |
129 |
1x50 |
6 |
1.4 |
10.9 |
0.641 |
7.011 |
166 |
1x70 |
12 |
1.4 |
12.6 |
0.443 |
10.354 |
229 |
1x95 |
15 |
1.6 |
14.8 |
0.32 |
13.727 |
315 |
1x120 |
15 |
1.6 |
16 |
0.253 |
17.339 |
386 |
1x150 |
15 |
1.8 |
18.1 |
0.206 |
21.033 |
476 |
1x185 |
30 |
2 |
20.1 |
0.164 |
26.732 |
594 |
1x240 |
30 |
2.2 |
22.8 |
0.125 |
34.679 |
777 |
1x300 |
30 |
2.2 |
24.9 |
0.1 |
43.349 |
955 |
1x400 |
53 |
2.2 |
27.6 |
0.0778 |
55.707 |
1205 |
2x10 |
6 |
1 |
11.6 |
3.08 |
1.65 |
84 |
2x16 |
6 |
1.2 |
14.4 |
1.91 |
2.517 |
131 |
2x25 |
6 |
1.2 |
16.8 |
1.2 |
3.762 |
189 |
2x35 |
6 |
1.4 |
19.6 |
0.868 |
5.177 |
261 |
2x50 |
6 |
1.4 |
21.8 |
0.641 |
7.011 |
336 |
2x70 |
12 |
1.4 |
25.2 |
0.443 |
10.354 |
463 |
2x95 |
15 |
1.6 |
29.6 |
0.32 |
13.727 |
637 |
2x120 |
15 |
1.6 |
32 |
0.253 |
17.339 |
779 |
4x10 |
6 |
1 |
14 |
3.08 |
1.65 |
167 |
4x16 |
6 |
1.2 |
17.4 |
1.91 |
2.517 |
262 |
4x25 |
6 |
1.2 |
20.3 |
1.2 |
3.762 |
378 |
4x35 |
6 |
1.4 |
23.7 |
0.868 |
5.177 |
522 |
4x50 |
6 |
1.4 |
26.4 |
0.641 |
7.011 |
672 |
4x70 |
12 |
1.4 |
30.5 |
0.443 |
10.354 |
926 |
4x95 |
15 |
1.6 |
35.8 |
0.32 |
13.727 |
1274 |
4x120 |
15 |
1.6 |
38.7 |
0.253 |
17.339 |
1558 |
GBT 12527
Nominal Size |
Min. No. of Wires |
Approx.Diameter of Conductor |
Nominal Thickness of Insulation |
Max. Diameter of Cable |
Max. DC Resistance at 20°C |
Breaking Load |
AAC |
AAAC |
AAC |
AAAC |
mm2 |
No. |
mm |
mm |
mm |
Ω/km |
Ω/km |
N |
N |
10 |
6 |
3.8 |
1 |
6.5 |
3.08 |
3.574 |
1650 |
2514 |
16 |
6 |
4.8 |
1.2 |
8 |
1.91 |
2.217 |
2517 |
4022 |
25 |
6 |
6 |
1.2 |
9.4 |
1.2 |
1.393 |
3762 |
6284 |
35 |
6 |
7 |
1.4 |
11 |
0.868 |
1.007 |
5177 |
8800 |
50 |
6 |
8.4 |
1.4 |
12.3 |
0.641 |
0.744 |
7011 |
12569 |
70 |
12 |
10 |
1.4 |
14.1 |
0.443 |
0.514 |
10354 |
17596 |
95 |
15 |
11.6 |
1.6 |
16.5 |
0.32 |
0.371 |
13727 |
23880 |
120 |
15 |
13 |
1.6 |
18.1 |
0.253 |
0.294 |
17339 |
30164 |
150 |
15 |
14.6 |
1.8 |
20.2 |
0.206 |
0.239 |
21033 |
37706 |
185 |
30 |
16.2 |
2 |
22.5 |
0.164 |
0.19 |
26732 |
46503 |
240 |
30 |
18.4 |
2.2 |
25.6 |
0.125 |
0.145 |
34679 |
60329 |
300 |
30 |
20.8 |
2.2 |
27.2 |
0.1 |
0.116 |
43349 |
75411 |
400 |
53 |
23.2 |
2.2 |
30.7 |
0.0778 |
0.0904 |
55707 |
100548 |
Production Details










Our advantages
* Always a pre-production sample before mass production
*Advanced production and testing equipment.* Strict controlling of raw materials.
* Raw material origin, factory direct sales, competitive price.
* Inquiry and consulting support.
* Free sample and sample testing support.
* Fast delivery.
* Good pre-sale and after-sale services.