Bare Copper Conductor ASTM BS DIN Tbt Standardfor Electrical Projects
|
Still deciding? Get samples of $ !
Order Sample
|
Product Details
| Customization: | Available |
|---|---|
| Type: | Insulated |
| Conductor Type: | Stranded |
Shipping
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Payment Guarantee
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Secured Trading Service
Diamond Member Since 2025
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Importers and Exporters
Fast Delivery
Management Certification
Product Certification
The supplier has import and export rights
The supplier can deliver the goods within 30 days
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
The supplier's products already have relevant certification qualifications, including:
CE
CCC
CE
CCC
Sign In to see all verified strength labels (22)
Find Similar Products
Basic Info.
- Model NO.
- Copper Conductor
- Application
- Overhead
- Conductor Material
- Aluminum
- Sheath Material
- PVC
- Insulation Material
- XLPE
- Material Shape
- Round Wire
- Range of Application
- Power Distribution for Overhead Facilities
- Certification
- ISO9001, CE, CCC, RoHS, VDE
- Brand
- Xunda
- Code Name
- Sac Cable
- Conductor
- Hard Drawn Aluminium Wire
- Conductor Screen
- XLPE Compound
- Insulation
- XLPE ( Crosslinked Polyethylene)
- Jacket
- Jacket: Black XLPE
- Transport Package
- Wooden Drum, Steel Drum, Steel&Wooden Drum, Pallet
- Specification
- ASTM B231, IEC61089, BS215, CSA C49, DIN 480201, I
- Trademark
- Xunda Cable
- Origin
- Henan
- HS Code
- 7614900000
- Production Capacity
- 3000 Tons/Month
Packaging & Delivery
- Package Size
- 110.00cm * 110.00cm * 110.00cm
- Package Gross Weight
- 100.000kg
Product Description
Copper Conductor
DESCRIPTION
Stranded bare copper and copper alloy are suitable for overhead power transmission systems and overhead electric traction systems.
APPLICATION
Stranded bare copper and copper alloy are suitable for overhead power transmission systems and overhead electric traction systems.
Standards
•ASTM B 8 • BS 7884 • DIN 48201 • TBT 3111
BS 7884
| Nominal area of cross-section of stranded conductor | Construction (stranding and wire diameter) | Overall diameter of conductor (approx.) | Nominal mass per unit length | Resistance at 20 °C | Minimum breaking load | |
| Nominal | Max. | |||||
| mm² | number/mm | mm | kg/km | Ω/km | Ω/km | N |
| 10 | 7/1.35 | 4.05 | 89.82 | 1.788 | 1.829 | 3752 |
| 14 | 7/1.60 | 4.8 | 126.2 | 1.273 | 1.303 | 5267 |
| 16 | 3/2.65 | 5.7 | 148.3 | 1.082 | 1.106 | 6194 |
| 16 | 7/1.70 | 5.1 | 142.4 | 1.128 | 1.154 | 5946 |
| 25 | 7/2.10 | 6.3 | 217.3 | 0.7391 | 0.7563 | 9073 |
| 32 | 3/3.75 | 8.06 | 296.9 | 0.5405 | 0.552 | 12400 |
| 32 | 7/2.46 | 7.38 | 298.2 | 0.5386 | 0.5497 | 12442 |
| 35 | 7/2.50 | 7.5 | 308 | 0.5215 | 0.5337 | 12860 |
| 50 | 7/3.00 | 9 | 443.5 | 0.3622 | 0.3706 | 18520 |
| 50 | 19/1.80 | 9 | 435.8 | 0.3727 | 0.3819 | 17700 |
| 70 | 7/3.55 | 10.65 | 621.1 | 0.2586 | 0.2646 | 25930 |
| 70 | 19/2.10 | 10.5 | 593.2 | 0.2738 | 0.2806 | 24090 |
| 95 | 19/2.50 | 12.5 | 840.7 | 0.1932 | 0.198 | 34140 |
| 100 | 7/4.30 | 12.9 | 911.2 | 0.1763 | 0.181 | 36540 |
| 120 | 19/2.80 | 14 | 1055 | 0.154 | 0.1578 | 42830 |
| 125 | 19/2.90 | 14.5 | 1131 | 0.1436 | 0.1471 | 45940 |
| 150 | 19/3.20 | 16 | 1377 | 0.118 | 0.1208 | 55940 |
| 150 | 37/2.25 | 15.75 | 1334 | 0.1233 | 0.1264 | 53880 |
| 185 | 19/3.55 | 17.75 | 1695 | 0.09582 | 0.09815 | 68860 |
| 185 | 37/2.50 | 17.5 | 1647 | 0.09981 | 0.1024 | 66490 |
| 12 | 3/2.30 | 4.95 | 112.4 | 1.743 | 1.78 | 6968 |
| 16 | 7/1.70 | 5.1 | 143.3 | 1.368 | 1.399 | 8883 |
| 22 | 7/2.00 | 6 | 198.3 | 0.9882 | 1.011 | 12290 |
| 25 | 7/2.10 | 6.3 | 218.7 | 0.8959 | 0.9171 | 13550 |
| 30 | 7/2.30 | 6.9 | 262.3 | 0.7469 | 0.7645 | 16260 |
| 35 | 7/2.50 | 7.5 | 309.9 | 0.6324 | 0.6471 | 19210 |
| 38 | 7/2.60 | 7.8 | 335.2 | 0.5847 | 0.5983 | 20780 |
| 45 | 7/2.90 | 8.7 | 417 | 0.4698 | 0.4809 | 24600 |
| 55 | 7/3.20 | 9.6 | 507.8 | 0.3859 | 0.395 | 29950 |
| 70 | 19/2.10 | 10.5 | 596.8 | 0.3316 | 0.3403 | 35990 |
| 75 | 7/3.70 | 11.1 | 678.8 | 0.2887 | 0.2954 | 38010 |
| 95 | 19/2.50 | 12.5 | 845.9 | 0.2343 | 0.24 | 51010 |
| 100 | 7/4.30 | 12.9 | 916.9 | 0.2138 | 0.2195 | 51160 |
| 120 | 19/2.80 | 14 | 1061 | 0.1862 | 0.1914 | 60890 |
| 125 | 19/2.90 | 14.5 | 1138 | 0.1739 | 0.1784 | 65310 |
| 150 | 19/3.20 | 16 | 1386 | 0.1428 | 0.1465 | 79530 |
| 150 | 37/2.25 | 15.75 | 1342 | 0.1493 | 0.1533 | 80490 |
| 180 | 19/3.50 | 17.5 | 1658 | 0.1196 | 0.1225 | 95140 |
| 180 | 37/2.50 | 17.5 | 1657 | 0.1209 | 0.1242 | 99330 |
| 200 | 19/3.70 | 18.5 | 1853 | 0.1068 | 0.1696 | 100900 |
| 240 | 19/4.00 | 20 | 2165 | 0.09153 | 0.09378 | 117900 |
ASTM B 8
| Size of Conductor | Size of Conductor | Nominal Conductor Diameter, inA | Nominal ConductorDiameler, inA | Nominal Conductor Diameler, inA | Nominal Conductor Diameler, inA | Nominal Conductor Diameler, inA | Mass | Mass | dc Resistance at 20°C | dc Resistance at 20°C | |
| Concentric Strand | Concentric Strand | Concentric Strand | Concentric Strand | Concentric Strand | |||||||
| cmil or AWG numbers | mm2 | Class A A | Class A | Class B | Reverse | Unilay Compressed | Area in2 | lbs/1000 ft | kg/km | Ω /1000 ft | Ω/km |
| Concentric | Diameter | ||||||||||
| Compreseed | in | ||||||||||
| Class B | |||||||||||
| Diameter | |||||||||||
| in | |||||||||||
| *5 000 000 cmil | 2530 | - | 2.58 | 2 581 | - | - | 3.927 | 15 890 | 23 649 | 0.00218 | 0.00715 |
| 4 500 000 cmil | 2280 | - | 2.448 | 2.448 | - | - | 3.534 | 14 300 | 21 283 | 0.00242 | 0.00794 |
| 4 000 000 cmil | 2030 | - | 2.307 | 2 309 | - | - | 3.142 | 12 590 | 18 738 | 0.0027 | 0.00888 |
| 3 500 000 cmil | 1770 | - | 2.158 | 2159 | - | - | 2.749 | 11 020 | 16 401 | 0.00308 | 0.0101 |
| *3 000 000 cmil | 1520 | - | 1.998 | 1.998 | - | - | 2.356 | 9353 | 13 920 | 0.00356 | 0.0117 |
| *2 500 000 cmil | 1270 | - | 1.823 | 1. .824 | - | - | 1.963 | 7 794 | 11 600 | 0.00427 | 0.014 |
| *2 000 000 cmil | 1010 | - | 1.63 | 1. .632 | 1.583 | 1.533 | 1.571 | 6175 | 9 190 | 0.00529 | 0.0174 |
| 1 900 000 cmil | 963 | - | 1. 590 | 1. .590 | 1.542 | 1.494 | 1.492 | 5 866 | 8 730 | 0.00557 | 0.0183 |
| 1 800 000 omil | 912 | - | 1. 547 | 1. .548 | 1.502 | 1.454 | 1.414 | 5558 | 8 272 | 0.00588 | 0.0193 |
| *1 750 000 cmil | 887 | - | 1.526 | 1.526 | 1 .480 | 1.434 | 1.374 | 5 403 | 8 041 | 0.00604 | 0.0198 |
| 1 700 000 cmil | 861 | - | 1.504 | 1. 504 | 1.459 | 1.413 | 1.335 | 5249 | 7812 | 0.00622 | 0.0204 |
| 1 600 000 cmil | 801 | - | 1.459 | 1.459 | 1.415 | 1.371 | 1.257 | 4 940 | 7352 | 0.00661 | 0.0217 |
| *1 500 000 cmil | 760 | - | 1.411 | 1.412 | 1.37 | 1.327 | 1.178 | 4 631 | 6 892 | 0.00705 | 0.0231 |
| 1 400 000 cmilt | 709 | - | 1. 364 | 1. .364 | 1.323 | 1.282 | 1.1 | 4 323 | 6 435 | 0.00756 | 0.0248 |
| 1 300 000 cmil | 659 | - | 1.314 | 1.315 | 1.275 | 1.236 | 1.021 | 4 014 | 5974 | 0.00814 | 0.0267 |
| *1 250 000 cmil | 633 | - | 1.288 | 1. .289 | 1.25 | 1.212 | 0.9817 | 3859 | 5 743 | 0.00846 | 0.0278 |
| 1 200 000 cmil | 608 | - | 1.263 | 1.263 | 1.225 | 1.187 | 0.9425 | 3 705 | 5514 | 0.00882 | 0.0289 |
| 1 100 000 cmil | 557 | - | 1. 209 | 1. 209 | 1.173 | 1.137 | 0.8639 | 3396 | 5 054 | 0.00962 | 0.0316 |
| *1 000 000 cmil | 507 | 1.151 | 1.152 | 1.152 | 1.117 | 1.084 | 0.7854 | 3088 | 4 596 | 0.0106 | 0.0348 |
| 900 000 cmil | 456 | 1.092 | 1.094 | 1.094 | 1.06 | 1.028 | 0.7069 | 2779 | 4 136 | 0.0118 | 0.0387 |
| *800 000 cmil | 405 | 1.029 | 1.031 | 1.031 | 1 | 0.969 | 0.6283 | 2470 | 3676 | 0.0132 | 0.0433 |
| *750 000 cmil | 380 | 0.997 | 0.998 | 0.998 | 0.968 | 0.939 | 0.5800 | 2316 | 3447 | 0.0141 | 0.0462 |
| *700 000 cmil | 355 | 0.963 | 0.964 | 0.964 | 0.935 | 0.907 | 0.5498 | 2161 | 3216 | 0.0151 | 0.0495 |
| 650 000 cmil | 329 | 0.928 | 0.929 | 0.929 | 0.901 | 0.874 | 0.5106 | 2007 | 2 987 | 0.0163 | 0.0535 |
| *600 000 cmil | 304 | 0.891 | 0.891 | 0.893 | 0.866 | 0.84 | 0.4712 | 1 853 | 2 758 | 0.0176 | 0.0578 |
| 550 000 cmil | 279 | 0.853 | 0.853 | 0.855 | 0.829 | 0.804 | 0.432 | 1 698 | 2527 | 0.0192 | 0.063 |
| *500 000 cmil | 253 | 0.811 | 0.813 | 0.813 | 0.789 | 0.766 | 0.3927 | 1 544 | 2298 | 0.0212 | 0.0695 |
| 450 000 cmil | 228 | 0.77 | 0.772 | 0.772 | 0.749 | 0.727 | 0 3534 | 1 389 | 2 067 | 0.0235 | 0.0771 |
| *400 000 cmil | 203 | 0.726 | 0.726 | 0.728 | 0.706 | 0.685 | 0.3142 | 1 235 | 1 838 | 0.0264 | 0.0866 |
| *350 000 cmil | 177 | 0.71 | 0.679 | 0.681 | 0.661 | 0.641 | 0.2749 | 1 081 | 1 609 | 0.0302 | 0.0991 |
| *300 000 cmil | 152 | 0.657 | 0.629 | 0.63 | 0.611 | 0.594 | 0.2356 | 926.3 | 1 378.6 | 0.0353 | 0.116 |
| *250 000 amil | 127 | 0.6 | 0.574 | 0.575 | 0.558 | 0.542 | 0.1963 | 771.9 | 1148.8 | 0.0423 | 0.139 |
| * No.0000 | 107 | 0.522 | 0 522 | 0.528 | 0.512 | 0.498 | 0.1662 | 653.1 | 972 | 0.05 | 0.164 |
| " No.000 | 85 | 0.464 | 0.464 | 0.47 | 0.456 | 0.443 | 0.1318 | 518.1 | 771.1 | 0.063 | 0.207 |
| * No. 00 | 67.4 | 0.414 | 0.414 | 0.419 | 0.405 | 0.395 | 0.1045 | 410.9 | 611.5 | 0.0795 | 0.261 |
| *No.0 | 53.5 | 0.368 | 0.368 | 0.373 | 0.362 | 0.352 | 0.08289 | 325.8 | 484.9 | 0.1 | 0.328 |
| * No, 1,3 wire | 42.4 | 0.36 | - | - | - | - | 0.06573 | 255.9 | 380.9 | 0.126 | 0.413 |
| * No. 1 | 42.4 | - | 0.328 | 0.332 | 0.322 | 0.313 | 0.06573 | 258.4 | 384.6 | 0.126 | 0.413 |
| *No.2,3wire | 33.6 | 0.32 | - | - | - | - | 0.05213 | 202.9 | 301.9 | 0.159 | 0.522 |
| *No.2 | 33.6 | - | 0.292 | 0.292 | 0.283 | - | 0.05213 | 204.9 | 304.9 | 0.159 | 0.522 |
| *No.3.3wire | 26.7 | 0.285 | - | - | - | - | 0.04134 | 160.9 | 239.5 | 0.201 | 0.659 |
| "No.3 | 26.7 | 0.26 | 0.26 | 0.252 | - | 0.04134 | 162.5 | 241.9 | 0.201 | 0.659 | |
| *No. 4, 3 wire | 21.2 | 0.254 | - | - | - | - | 0.03278 | 127.6 | 189.9 | 0.253 | 0.83 |
| "No.4 | 21.2 | - | 232 | 0.232 | 0.225 | - | 0.03278 | 128.9 | 191.8 | 0.253 | 0.83 |
| * No.5 | 16.8 | - | - | 0.206 | 0.2 | - | 0.026 | 102.2 | 152.1 | 0.319 | 1.05 |
| *No. 6 | 13.3 | - | - | 0.184 | 0.178 | - | 0.02062 | 81.05 | 120.63 | 0.403 | 1.32 |
| * No.7 | 10.6 | - | - | 0.164 | 0.159 | - | 0.01635 | 64.28 | 95.67 | 0.509 | 1.67 |
| * No.8 | 8.37 | - | - | 0.146 | 0.142 | - | 0.01297 | 50.97 | 75.86 | 0.64 | 2.1 |
| * No.9 | 6.63 | - | - | 0.13 | 0.126 | - | 0.01028 | 40.42 | 60.16 | 0.809 | 2.65 |
| * No. 10 | 5.26 | - | - | 0.116 | 0.113 | - | 0.008155 | 32.06 | 47.72 | 1.02 | 3.35 |
| * No. 12 | 3.31 | - | - | 0.0915 | 0.089 | - | 0.005129 | 20.16 | 30 | 1.63 | 5.35 |
| * No.14 | 2.08 | - | - | 0.0726 | 0.071 | - | 0.003225 | 12.68 | 18.87 | 2.58 | 8.46 |
| * No. 16 | 0.823 | - | - | 0.0576 | - | - | 0.002028 | 7.974 | 11.868 | 4.1 | 13.45 |
| *No.18 | 0.519 | - | - | 0.0456 | - | - | 0.001276 | 5.015 | 7.484 | 6.54 | 21.46 |
| * No.20 | 0.519 | - | - | 0.0363 | - | - | 0.0008023 | 3.154 | 4.694 | 10.3 | 33.8 |
| * No.22 | 0.324 | - | - | 0.0288 | - | - | 0.0005067 | 1.992 | 2.965 | 16.4 | 53.8 |
| * No.24 | 0.205 | - | - | 0.0228 | - | - | 0.0003176 | 1.249 | 1.859 | 26.1 | 85.6 |
- Class A conductors are suitable for covering with weather-resistant materials or for bare applications where more flexibility than Class AA is needed.
- Class B conductors are designed for insulating with various materials or for more flexible applications than Class A.
- Class C and D conductors offer even more flexibility than Class B and are used where extreme bending is required.
DIN 48201
| Nominal area | Cross- sectional | Wire | Overall | Approx. mass per | Rated strength | Current carrying | |
| mm2 | area | diameter | unit length | kN | capacity | ||
| mm2 | Number | Diameter | mm | kg/km | A | ||
| mm | |||||||
| 10 | 10.02 | 7 | 1.35 | 4.1 | 90 | 4.02 | 90 |
| 16 | 15.89 | 7 | 1.7 | 5.1 | 143 | 6.37 | 125 |
| 25 | 24.25 | 7 | 2.1 | 6.3 | 218 | 9.72 | 160 |
| 35 | 34.36 | 7 | 2.5 | 7.5 | 310 | 13.77 | 200 |
| 50 | 49.48 | 7 | 3 | 9 | 446 | 19.84 | 250 |
| 48.35 | 19 | 1.8 | 9 | 437 | 19.38 | 250 | |
| 70 | 65.81 | 19 | 2.1 | 10.5 | 596 | 26.38 | 310 |
| 95 | 93.27 | 19 | 2.5 | 12.5 | 845 | 37.39 | 380 |
| 120 | 116.99 | 19 | 2.8 | 14 | 1060 | 46.9 | 440 |
| 150 | 147.11 | 37 | 2.25 | 15.8 | 1337 | 58.98 | 510 |
| 185 | 181.62 | 37 | 2.5 | 17.5 | 1649 | 72.81 | 585 |
| 240 | 242.54 | 61 | 2.25 | 20.3 | 2209 | 97.23 | 700 |
| 300 | 299.43 | 61 | 2.5 | 22.5 | 2725 | 120.04 | 800 |
| 400 | 400.14 | 61 | 2.89 | 26 | 3640 | 160.42 | 960 |
| 500 | 499.83 | 61 | 3.23 | 29.1 | 4545 | 200.38 | 1110 |
TBT 3111
| Type | Section area | Calculated overall | Structure | Single wire diameter | Single wire | Stranded wire (Nominal) | ||||
| mm2 | diameter | mm | Min. tensile strength | Min. | Min. | Mass per | ||||
| mm | MPa | elongation | breaking load | unit length | ||||||
| Nominal | Cross- sectional | Before | After | % | kN | kg/km | ||||
| stranding | stranding | |||||||||
| JT | 70 | 65.81 | 10.5 | 1×19 | 2.1 | 430 | 410 | 0.7 | 27.45 | 596 |
| JT | 95 | 93.27 | 12.5 | 1×19 | 2.5 | 430 | 410 | 0.7 | 38.54 | 844 |
| JT | 120 | 116.99 | 14 | 1×19 | 2.8 | 430 | 410 | 0.7 | 48.01 | 1059 |
| JT | 150 | 147.12 | 15.75 | 1×37 | 2.25 | 430 | 410 | 0.7 | 61.21 | 1334 |
| JTM | 25 | 24.25 | 6.3 | 1×7 | 2.1 | 520 | 494 | - | 11.98 | 218 |
| JTM | 35 | 34.36 | 7.5 | 1×7 | 2.5 | 520 | 494 | - | 16.97 | 309 |
| JTM | 35 | 34.93 | 7.65 | 1×19 | 1.53 | 520 | 494 | - | 17.26 | 316 |
| JTM | 50 | 49.48 | 9 | 1×7 | 3 | 520 | 494 | - | 24.44 | 446 |
| JTM | 50 | 48.35 | 9 | 1×19 | 1.8 | 520 | 494 | - | 23.88 | 438 |
| JTM | 70 | 65.81 | 10.5 | 1×19 | 2.1 | 520 | 494 | - | 32.51 | 596 |
| JTM | 95 | 93.27 | 12.5 | 1×19 | 2.5 | 520 | 494 | - | 46.08 | 844 |
| JTM | 120 | 116.99 | 14 | 1×19 | 2.8 | 520 | 494 | - | 57.79 | 1059 |
| JTM | 150 | 147.12 | 15.75 | 1×37 | 2.25 | 520 | 494 | - | 72.67 | 1334 |
| JTMH | 25 | 24.25 | 6.3 | 1×7 | 2.1 | 620 | 589 | - | 14.28 | 218 |
| JTMH | 35 | 34.36 | 7.5 | 1×7 | 2.5 | 620 | 589 | - | 20.24 | 309 |
| JTMH | 35 | 34.93 | 7.65 | 1×19 | 1.53 | 620 | 589 | - | 20.57 | 316 |
| JTMH | 50 | 49.48 | 9 | 1×7 | 3 | 620 | 589 | - | 29.14 | 446 |
| JTMH | 50 | 48.35 | 9 | 1×19 | 1.8 | 620 | 589 | - | 28.48 | 438 |
| JTMH | 70 | 65.81 | 10.5 | 1×19 | 2.1 | 620 | 589 | - | 38.76 | 596 |
| JTMH | 95 | 93.27 | 12.5 | 1×19 | 2.5 | 620 | 589 | - | 54.94 | 844 |
| JTMH | 120 | 116.99 | 14 | 1×19 | 2.8 | 620 | 589 | - | 68.91 | 1059 |
| JTMH | 150 | 147.11 | 15.75 | 1×37 | 2.25 | 620 | 589 | - | 86.65 | 1334 |
| JTMM | 70 | 65.81 | 10.5 | 1×19 | 2.1 | 620 | 589 | - | 38.76 | 596 |
| JTMM | 95 | 93.27 | 12.5 | 1×19 | 2.5 | 620 | 589 | - | 54.94 | 844 |
| JTMM | 120 | 116.99 | 14 | 1×19 | 2.8 | 620 | 589 | - | 68.91 | 1059 |
| JTMM | 150 | 147.11 | 15.75 | 1×37 | 2.25 | 620 | 589 | - | 86.65 | 1334 |
| JTCZ120 | 120 | 119.75 | 14.21 | 1×37 | 2.03 | 520 | 494 | - | 59.16 | 1092 |
Industry Solutions
Power grid
New energy
Building
Industry
Marine cable
Telecommunication
Railway
Instrument
Power grid
New energy
Building
Industry
Marine cable
Telecommunication
Railway
Instrument
Our Certificate

Company Information




FAQ
1. Q:Are you a factory or trading company?
A: Manufacturing base in Henan ,China, with more than 150 workers.
2. Q:How can I visit there?
A: Sure,lf you need,we will arrange the driver to pick you up.
3. Q:How can I get some samples?
A: Contact me on below,Determine sample and address for shipping.
4. Q:Have you ever supplied cables to our country?
A: Xunda Cable have been sold to over 30 countries and regions in the world. you cancontact me for details.
5. Q:What is your MOQ?
A: MOQ Normally 1km for insulated cables(1 ton for bare conductor).Please contact mefor detail info if you have specific cable requirement.
6. Q:When can l get the price?
A: Usually quote within 3hours after we get your inquiry.
7. Q:How long is your delivery time?
A: According to your order's quantity.Usually our lead time is 3 - 20 working days.
Send your message to this supplier
People who viewed this also viewed
Product Groups
Find Similar Products By Category
- Supplier Homepage
- Products
- Aluminum Bare Conductor
- Others Aluminum Bare Conductor
- Bare Copper Conductor ASTM BS DIN Tbt Standardfor Electrical Projects
Related Categories
Hot Searches
More