Reliable BS En 50182 Certified Bare ACSR Bare Conductor for Long-Distance Power Lines

Product Details
Customization: Available
Application: Construction, Overhead, Underground, Industrial, Power Station, Telecommunication, Computer, Car
Voltage: Low and Medium Voltage Cable
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 30 days
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
CCC
to see all verified strength labels (22)
  • Reliable BS En 50182 Certified Bare ACSR Bare Conductor for Long-Distance Power Lines
  • Reliable BS En 50182 Certified Bare ACSR Bare Conductor for Long-Distance Power Lines
  • Reliable BS En 50182 Certified Bare ACSR Bare Conductor for Long-Distance Power Lines
  • Reliable BS En 50182 Certified Bare ACSR Bare Conductor for Long-Distance Power Lines
  • Reliable BS En 50182 Certified Bare ACSR Bare Conductor for Long-Distance Power Lines
  • Reliable BS En 50182 Certified Bare ACSR Bare Conductor for Long-Distance Power Lines
Find Similar Products

Basic Info.

Model NO.
ACSR
Current
DC & AC
Insulation Material
Bare
Sheath Material
Bare
Material Shape
Round Wire
Wire Core Material
Steel
Certification
ISO, CCC, CE, RoHS, VDE
Model
AGRP
Brand
Xunda Cable
Standard
IEC ASTM BS as Gbt Cable
Quality
100% Test It
Range of Application
Overhead
Transport Package
Wooden Drum, Steel Drum, Steel&Wooden Drum, Pallet
Specification
Aluminum Alloy
Trademark
Xunda Cable
Origin
Henan
HS Code
7614900000
Production Capacity
3000 Tons/Month

Product Description

ACSR 

Reliable BS En 50182 Certified Bare ACSR Bare Conductor for Long-Distance Power Lines
DESCRIPTION
Aluminium Conductor Steel Reinforced (ACSR) is concentrically stranded conductor with one or more layers of hard drawn aluminium wire on galvanized steel wire core. The core can be single wire or stranded depending on the size. Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease.

APPLICATION
Used as bare overhead transmission conductor and as primary and secondary distribution conductor and messenger support. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
Reliable BS En 50182 Certified Bare ACSR Bare Conductor for Long-Distance Power Lines

Standards 
•IEC61089    • ASTM B 232    • BS EN 50182    • AS 3607    • GB/T 1179

BS EN 50182(Germany)
Code Old Code Areas No. of Wires Wire Diameter Diameter Mass per unit Length Rated Strength DC Resistance
Al Steel Total Al Steel Core Cond.
mm2 mm2 mm2 Al Steel mm mm mm mm kg/km kN Ω/km
15-AL1/3-ST1A 16/2.5 15.3 2.54 17.8 6 1 1.8 1.8 1.8 5.4 61.6 5.8 1.8769
24-AL1/4-ST1A 25/4 23.9 3.98 27.8 6 1 2.25 2.25 2.25 6.75 96.3 8.95 1.2012
34-AL1/6-ST1A 35/6 34.4 5.73 40.1 6 1 2.7 2.7 2.7 8.1 138.7 12.37 0.8342
44-AL1/32-ST1A 44/32 44 31.7 75.6 14 7 2 2.4 7.2 11.2 369.3 44.24 0.6574
48-AL1/8-ST1A 50/8 48.3 8.04 56.3 6 1 3.2 3.2 3.2 9.6 194.8 16.81 0.5939
51-AL1/30-ST1A 50/30 51.2 29.8 81 12 7 2.33 2.33 6.99 11.7 374.7 42.98 0.5644
70-AL1/11-ST1A 70/12 69.9 11.4 81.3 26 7 1.85 1.44 4.32 11.7 282.2 26.27 0.4132
94-AL1/15-ST1A 95/15 94.4 15.3 109.7 26 7 2.15 1.67 5.01 13.6 380.6 34.93 0.306
97-AL1/56-ST1A 95/55 96.5 56.3 152.8 12 7 3.2 3.2 9.6 16 706.8 77.85 0.2992
106-AL1/76-ST1A 105/75 105.7 75.5 181.2 14 19 3.1 2.25 11.3 17.5 885.3 105.82 0.2742
122-AL1/20-ST1A 120/20 121.6 19.8 141.4 26 7 2.44 1.9 5.7 15.5 491 44.5 0.2376
122-AL1/71-ST1A 120/70 122.1 71.3 193.4 12 7 3.6 3.6 10.8 18 894.5 97.92 0.2364
128-AL1/30-ST1A 125/30 127.9 29.8 157.8 30 7 2.33 2.33 6.99 16.3 587 56.41 0.226
149-AL1/24-ST1A 150/25 148.9 24.2 173.1 26 7 2.7 2.1 6.3 17.1 600.8 53.67 0.194
172-AL1/40-ST1A 170/40 171.8 40.1 211.8 30 7 2.7 2.7 8.1 18.9 788.2 74.89 0.1683
184-AL1/30-ST1A 185/30 183.8 29.8 213.6 26 7 3 2.33 6.99 19 741 65.27 0.1571
209-AL1/34-ST1A 210/35 209.1 34.1 243.2 26 7 3.2 2.49 7.47 20.3 844.1 73.36 0.1381
212-AL1/49-ST1A 210/50 212.1 49.5 261.5 30 7 3 3 9 21 973.1 92.46 0.1363
231-AL1/30-ST1A 230/30 230.9 29.8 260.8 24 7 3.5 2.33 6.99 21 870.9 72.13 0.125
243-AL1/39-ST1A 240/40 243.1 39.5 282.5 26 7 3.45 2.68 8.04 21.8 980.1 85.12 0.1188
264-AL1/34-ST1A 265/35 263.7 34.1 297.7 24 7 3.74 2.49 7.47 22.4 994.4 81.04 0.1095
304-AL1/49-ST1A 300/50 304.3 49.5 353.7 26 7 3.86 3 9 24.4 1227.3 105.09 0.0949
305-AL1/39-ST1A 305/40 304.6 39.5 344.1 54 7 2.68 2.68 8.04 24.1 1151.2 96.8 0.0949
339-AL1/30-ST1A 340/30 339.3 29.8 369.1 48 7 3 2.33 6.99 25 1171.2 91.71 0.0852
382-AL1/49-ST1A 380/50 381.7 49.5 431.2 54 7 3 3 9 27 1442.5 121.3 0.0758
386-AL1/34-ST1A 385/35 386 34.1 420.1 48 7 3.2 2.49 7.47 26.7 1333.6 102.56 0.0749
434-AL1/56-ST1A 435/55 434.3 56.3 490.6 54 7 3.2 3.2 9.6 28.8 1641.3 133.59 0.0666
449-AL1/39-ST1A 450/40 448.7 39.5 488.2 48 7 3.45 2.68 8.04 28.7 1549.1 119.05 0.0644
490-AL1/64-ST1A 490/65 490.3 63.6 553.8 54 7 3.4 3.4 10.2 30.6 1852.9 150.81 0.059
494-AL1/34-ST1A 495/35 494.4 34.1 528.4 45 7 3.74 2.49 7.47 29.9 1632.6 117.96 0.0584
511-AL1/45-ST1A 510/45 510.5 45.3 555.8 48 7 3.68 2.87 8.61 30.7 1765.3 133.31 0.0566
550-AL1/71-ST1A 550/70 549.7 71.3 620.9 54 7 3.6 3.6 10.8 32.4 2077.2 166.32 0.0526
562-AL1/49-ST1A 560/50 561.7 49.5 611.2 48 7 3.86 3 9 32.2 1939.5 146.28 0.0515
571-AL1/39-ST1A 570/40 571.2 39.5 610.6 45 7 4.02 2.68 8.04 32.2 1887.1 136.4 0.0506
653-AL1/45-ST1A 650/45 653.5 45.3 698.8 45 7 4.3 2.87 8.61 34.4 2159.9 156.18 0.0442
679-AL1/86-ST1A 680/85 678.6 86 764.5 54 19 4 2.4 12 36 2549.7 206.56 0.0426
1046-AL1/45-ST1A 1045/45 1045.6 45.3 1090.9 72 7 4.3 2.87 8.61 43 3248.2 218.92 0.0277


BS EN 50182(United Kingdom)
 
Code Old Areas No.of Wire Diameter Diameter Mass per Rated DC
Code Al Steel Total Wires Al Steel Core Cond. Unit Length Strength Resistance
  mm2 mm2 mm2 Al Steel mm mm mm mm kg/km kN Ω/km
11-AL1/2-ST1A MOLE 10.6 1.77 12.4 6 1 1.5 1.5 1.5 4.5 42.8 4.14 2.7027
21-AL1/3-ST1A SQUIRREL 21 3.5 24.5 6 1 2.11 2.11 2.11 6.33 84.7 7.87 1.3659
26-AL1/4-ST1A GOPHER 26.2 4.37 30.6 6 1 2.36 2.36 2.36 7.08 106 9.58 1.0919
32-AL1/5-ST1A WEASEL 31.6 5.27 36.9 6 1 2.59 2.59 2.59 7.77 127.6 11.38 0.9065
37-AL1/6-ST1A FOX 36.7 6.11 42.8 6 1 2.79 2.79 2.79 8.37 148.1 13.21 0.7812
42-AL1/7-ST1A FERRET 42.4 7.07 49.5 6 1 3 3 3 9 171.2 15.27 0.6757
53-AL1/9-ST1A RABBIT 52.9 8.81 61.7 6 1 3.35 3.35 3.35 10.1 213.5 18.42 0.5419
63-AL1/11-ST1A MINK 63.1 10.5 73.6 6 1 3.66 3.66 3.66 11 254.9 21.67 0.454
63-AL1/37-ST1A SKUNK 63.2 36.9 100.1 12 7 2.59 2.59 7.77 13 463 52.79 0.4568
75-AL1/13-ST1A BEAVER 75 12.5 87.5 6 1 3.99 3.99 3.99 12 302.9 25.76 0.382
73-AL1/43-ST1A HORSE 73.4 42.8 116.2 12 7 2.79 2.79 8.37 14 537.3 61.26 0.3936
79-AL1/13-ST1A RACOON 78.8 13.1 92 6 1 4.09 4.09 4.09 12.3 318.3 27.06 0.3635
84-AL1/14-ST1A OTTER 83.9 14 97.9 6 1 4.22 4.22 4.22 12.7 338.8 28.81 0.3415
95-AL1/16-ST1A CAT 95.4 15.9 111.3 6 1 4.5 4.5 4.5 13.5 385.3 32.76 0.3003
105-AL1/17-ST1A HARE 105 17.5 122.5 6 1 4.72 4.72 4.72 14.2 423.8 36.04 0.273
105-AL1/14-ST1A DOG 105 13.6 118.5 6 7 4.72 1.57 4.71 14.2 394 32.65 0.2733
132-AL1/20-ST1A COYOTE 131.7 20.1 151.8 26 7 2.54 1.91 5.73 15.9 520.7 45.86 0.2192
132-AL1/7-ST1A COUGAR 131.5 7.3 138.8 18 1 3.05 3.05 3.05 15.3 418.8 29.74 0.2188
131-AL1/31-ST1A TIGER 131.2 30.6 161.9 30 7 2.36 2.36 7.08 16.5 602.2 57.87 0.2202
158-AL1/37-ST1A WOLF 158.1 36.9 194.9 30 7 2.59 2.59 7.77 18.1 725.3 68.91 0.1829
159-AL1/9-ST1A DINGO 158.7 8.8 167.5 18 1 3.35 3.35 3.35 16.8 505.2 35.87 0.1814
183-AL1/43-ST1A LYNX 183.4 42.8 226.2 30 7 2.79 2.79 8.37 19.5 841.6 79.97 0.1576
184-AL1/10-ST1A CARACAL 184.2 10.2 194.5 18 1 3.61 3.61 3.61 18.1 586.7 40.74 0.1562
212-AL1/49-ST1A PANTHER 212.1 49.5 261.5 30 7 3 3 9 21 973.1 92.46 0.1363
211-AL1/12-ST1A JAGUAR 210.6 11.7 222.3 18 1 3.86 3.86 3.86 19.3 670.8 46.57 0.1366
238-AL1/56-ST1A LION 238.3 55.6 293.9 30 7 3.18 3.18 9.54 22.3 1093.4 100.47 0.1213
264-AL1/62-ST1A BEAR 264.4 61.7 326.1 30 7 3.35 3.35 10.1 23.5 1213.4 111.5 0.1093
324-AL1/76-ST1A GOAT 324.3 75.7 400 30 7 3.71 3.71 11.1 26 1488.2 135.13 0.0891
375-AL1/88-ST1A SHEEP 375.1 87.5 462.6 30 7 3.99 3.99 12 27.9 1721.3 156.3 0.0771
374-AL1/48-ST1A ANTELOPE 374.1 48.5 422.6 54 7 2.97 2.97 8.91 26.7 1413.8 118.88 0.0773
382-AL1/49-ST1A BISON 381.7 49.5 431.2 54 7 3 3 9 27 1442.5 121.3 0.0758
430-AL1/100-ST1A DEER 429.6 100.2 529.8 30 7 4.27 4.27 12.8 29.9 1971.4 179 0.0673
429-AL1/56-ST1A ZEBRA 428.9 55.6 484.5 54 7 3.18 3.18 9.54 28.6 1620.8 131.92 0.0674
477-AL1/111-ST1A ELK 477.1 111.3 588.5 30 7 4.5 4.5 13.5 31.5 2189.5 198.8 0.0606
476-AL1/62-ST1A CAMEL 476 61.7 537.7 54 7 3.35 3.35 10.1 30.2 1798.8 146.4 0.0608
528-AL1/69-ST1A MOOSE 528.5 68.5 597 54 7 3.53 3.53 10.6 31.8 1997.3 159.92 0.0547

Reliable BS En 50182 Certified Bare ACSR Bare Conductor for Long-Distance Power Lines
Industry Solutions
Power grid
New energy
Building
Industry
Marine cable
Telecommunication
Railway
Instrument


Our Certificate
Reliable BS En 50182 Certified Bare ACSR Bare Conductor for Long-Distance Power Lines
Company Information


Reliable BS En 50182 Certified Bare ACSR Bare Conductor for Long-Distance Power LinesReliable BS En 50182 Certified Bare ACSR Bare Conductor for Long-Distance Power LinesReliable BS En 50182 Certified Bare ACSR Bare Conductor for Long-Distance Power LinesReliable BS En 50182 Certified Bare ACSR Bare Conductor for Long-Distance Power Lines
FAQ

1. Q:Are you a factory or trading company?
A: Manufacturing base in Henan ,China, with more than 150 workers.

2. Q:How can I visit there?
A: Sure,lf you need,we will arrange the driver to pick you up.

3. Q:How can I get some samples?
A: Contact me on below,Determine sample and address for shipping.

4. Q:Have you ever supplied cables to our country?
A: Xunda Cable have been sold to over 30 countries and regions in the world. you cancontact me for details.

5. Q:What is your MOQ?
A: MOQ Normally 1km for insulated cables(1 ton for bare conductor).Please contact mefor detail info if you have specific cable requirement.

6. Q:When can l get the price?
A: Usually quote within 3hours after we get your inquiry.

7. Q:How long is your delivery time?
A: According to your order's quantity.Usually our lead time is 3 - 20 working days.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier