50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line

Product Details
Customization: Available
Type: Bare
Conductor Type: Stranded
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 30 days
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
CCC
to see all verified strength labels (22)
  • 50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line
  • 50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line
  • 50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line
  • 50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line
  • 50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line
  • 50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line
Find Similar Products

Basic Info.

Model NO.
AAC
Application
Overhead
Conductor Material
Aluminum
Sheath Material
Bare
Insulation Material
Bare
Material Shape
Round Wire
Range of Application
LSOH
Certification
ISO9001, CE, CCC
Brand
Xunda
Product Capacity
3000t/Year
Material
AAC
Standard
BS En 50182
Size
10mm2-1500mm2
Conductivity
52%-61% Iacs
Ampacity
5A/mm2
Elastic Modulus
70gpa
Package Length
Customized
Ome Accepted
Yes
Third Party Inspection
Yes
Transport Package
Drum
Specification
1.1*1.1*1.0
Trademark
XUNDA
Origin
China
HS Code
7614900000
Production Capacity
500km/Month

Packaging & Delivery

Package Size
100.00cm * 20.00cm * 20.00cm
Package Gross Weight
1.000kg

Product Description

50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line
AAC is used mainly in urban areas where the spacing is short and the supports are close. All aluminium conductors are made up of one or more strands of aluminium wire depending on the end usage. AAC is also used extensively in coastal regions because it has a high degree of corrosion resistance.Concentric lay stranded Aluminium Conductors (AAC) are made out of Hard-Drawn aluminum wires.
AAAC is used as a bare overhead conductor for power transmission and distribution lines, on aerial circuits that require a larger mechanical resistance than AAC, and a better corrosion resistance than ACSR. The sag characteristics and the strength-to-weight ratio of AAAC is better than both AAC / ACSR.Concentric lay stranded Aluminium Alloy Conductors (AAAC) are made out of high strength Aluminium-Magnesium-Silicon Alloy.
Used as bare overhead transmission conductor and as primary and secondary distribution conductor and messenger support. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
Aluminium Conductor Steel Reinforced (ACSR) is concentrically stranded conductor with one or more layers of hard drawn aluminium wire on galvanized steel wire core. The core can be single wire or stranded depending on the size. Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease

 

 

BS EN 50182

BS EN 50182 (Germany)AAC

 
Code Old Code Area No. of Wires Diameter Mass per Unit Length Rated Strength DC
Wire Cond. Resistance
mm2 mm mm kg/km kN Ω/km
16-AL1 16 15.9 7 1.7 5.1 43.4 3.02 1.7986
24-AL1 25 24.2 7 2.1 6.3 66.3 4.36 1.1787
34-AL1 35 34.4 7 2.5 7.5 93.9 6.01 0.8317
49-AL1 50 49.5 7 3 9 135.2 8.41 0.5776
48-AL1 50 48.3 19 1.8 9 132.9 8.94 0.5944
66-AL1 70 65.8 19 2.1 10.5 180.9 11.85 0.4367
93-AL1 95 93.3 19 2.5 12.5 256.3 16.32 0.3081
117-AL1 120 117 19 2.8 14 321.5 19.89 0.2456
147-AL1 150 147.1 37 2.25 15.8 405.7 26.48 0.196
182-AL1 185 181.6 37 2.5 17.5 500.9 31.78 0.1588
243-AL1 240 242.5 61 2.25 20.3 671.1 43.66 0.1193
299-AL1 300 299.4 61 2.5 22.5 828.5 52.4 0.0966
400-AL1 400 400.1 61 2.89 26 1107.1 68.02 0.0723
500-AL1 500 499.8 61 3.23 29.1 1382.9 82.47 0.0579
626-AL1 625 626.2 91 2.96 32.6 1739.7 106.45 0.0464
802-AL1 800 802.1 91 3.35 36.9 2228.3 132.34 0.0362
1000-AL1 1000 999.7 91 3.74 41.1 2777.3 159.95 0.0291
50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line
50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line
 

BS EN 50182

 BS EN 50182 (United Kingdom)
AAC
Code Old Area   Diameter Mass per Rated DC
code No.of Wire Cond. Unit length Strength Resistance
  mm2 wires mm mm kg/km kN Ω/km
23-AL1 MIDGE 23.3 7 2.06 6.18 63.8 4.2 1.2249
27-AL1 GNAT 26.9 7 2.21 6.63 73.4 4.83 1.0643
37-AL1 MOSQUITO 36.9 7 2.59 7.77 100.8 6.27 0.7749
43-AL1 LADYBIRD 42.8 7 2.79 8.37 117 7.28 0.6678
53-AL1 ANT 52.8 7 3.1 9.3 144.4 8.72 0.5409
64-AL1 FLY 63.6 7 3.4 10.2 173.7 10.49 0.4497
74-AL1 BLUEBOTTLE 73.6 7 3.66 11 201.3 11.78 0.388
79-AL1 EARWIG 78.6 7 3.78 11.3 214.7 12.57 0.3638
84-AL1 GRASSHOPPER 84.1 7 3.91 11.7 229.7 13.45 0.34
96-AL1 CLEGG 95.6 7 4.17 12.5 261.3 15.3 0.2989
106-AL1 WASP 106 7 4.39 13.2 289.6 16.95 0.2697
106-AL1 BEETLE 106.4 19 2.67 13.4 292.4 18.08 0.2701
132-AL1 BEE 132 7 4.9 14.7 360.8 21.12 0.2165
158-AL1 HORNET 157.6 19 3.25 16.3 433.2 26.01 0.1823
186-AL1 CATERPILLAR 185.9 19 3.53 17.7 511.1 29.75 0.1546
213-AL1 CHAFER 213.2 19 3.78 18.9 586 34.12 0.1348
238-AL1 SPIDER 237.6 19 3.99 20 652.9 38.01 0.121
266-AL1 COCKROACH 265.7 19 4.22 21.1 730.4 42.52 0.1081
323-AL1 BUTTERFLY 322.7 19 4.65 23.3 886.8 51.63 0.0891
373-AL1 MOTH 373.1 19 5 25 1025.3 59.69 0.077
372-AL1 DRONE 372.4 37 3.58 25.1 1027.1 59.59 0.0774
415-AL1 CENTIPEDE 415.2 37 3.78 26.5 1145.1 66.43 0.0695
486-AL1 MAYBUG 486.1 37 4.09 28.6 1340.6 77.78 0.0593
530-AL1 SCORPION 529.8 37 4.27 29.9 1461.2 84.77 0.0544
628-AL1 CICADA 628.3 37 4.65 32.6 1732.9 100.54 0.0459
 
50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line
50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line
 

 

 
 
50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line
50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line




 
50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line
 
 
50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line
50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line
50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line

50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line



50 75 90mm2 Reliable British Standard AAC Power Transmission and Distribution Line

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier