Durable High Conductivity IEC AAC BS AC Conductor for Energy Solutions

Product Details
Customization: Available
Application: Construction, Overhead, Underground, Industrial, Power Station, Telecommunication, Computer, Car
Voltage: Low and Medium Voltage Cable
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 30 days
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
CCC
to see all verified strength labels (22)
  • Durable High Conductivity IEC AAC BS AC Conductor for Energy Solutions
  • Durable High Conductivity IEC AAC BS AC Conductor for Energy Solutions
  • Durable High Conductivity IEC AAC BS AC Conductor for Energy Solutions
  • Durable High Conductivity IEC AAC BS AC Conductor for Energy Solutions
  • Durable High Conductivity IEC AAC BS AC Conductor for Energy Solutions
  • Durable High Conductivity IEC AAC BS AC Conductor for Energy Solutions
Find Similar Products

Basic Info.

Model NO.
AAC
Current
DC & AC
Insulation Material
Bare
Sheath Material
Bare
Material Shape
Round Wire
Wire Core Material
Steel
Certification
ISO, CCC, CE, RoHS, VDE
Model
AGRP
Brand
Xunda Cable
Standard
ASTM BS AC Gbt
Color
Silvery White
Range of Application
Construction, Overhead, Underground, Industrial, P
Transport Package
Wooden Drum, Steel Drum, Steel&Wooden Drum, Pallet
Specification
BS215
Trademark
Xunda Cable
Origin
Henan
HS Code
7614900000
Production Capacity
5000 Tons/Month

Product Description


AAC (All aluminum conductor)


AAC(All aluminum conductor) are suited for overhead power line.

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.

 
Durable High Conductivity IEC AAC BS AC Conductor for Energy Solutions
Durable High Conductivity IEC AAC BS AC Conductor for Energy Solutions

Product Name All Aluminum Conductor  (AAC)
Material Aluminum
Color Silvery white
Standard BS, ASTM, ACSA, DIN, IEC, GB/T...
Used Power transmission lines with various voltage


Standards 

IEC 61089
Area No.of Diameter Linear Rated D.C.
Wires Wire Cond. Mass Strength Resistance
mm2   mm mm kg/km kN Ω/km
10 7 1.35 4.05 27.4 1.95 2.8633
16 7 1.71 5.12 43.8 3.04 1.7896
25 7 2.13 6.4 68.4 4.5 1.1453
40 7 2.7 8.09 109.4 6.8 0.7158
63 7 3.39 10.2 172.3 10.39 0.4545
100 19 2.59 12.9 274.8 17 0.2877
125 19 2.89 14.5 343.6 21.25 0.2302
160 19 3.27 16.4 439.8 26.4 0.1798
200 19 3.66 18.3 549.7 32 0.1439
250 19 4.09 20.5 687.1 40 0.1151
315 37 3.29 23 867.9 51.97 0.0916
400 37 3.71 26 1102 64 0.0721
450 37 3.94 27.5 1239.8 72 0.0641
500 37 4.15 29 1377.6 80 0.0577
560 37 4.39 30.7 1542.9 89.6 0.0515
630 61 3.63 32.6 1738.3 100.8 0.0458
710 61 3.85 34.6 1959.1 113.6 0.0407
800 61 4.09 36.8 2207.4 128 0.0361
900 61 4.33 39 2483.3 144 0.0321
1000 61 4.57 41.1 2759.2 160 0.0289
1120 91 3.96 43.5 3093.5 179.2 0.0258
1250 91 4.18 46 3452.6 200 0.0231
1400 91 4.43 48.7 3866.9 224 0.0207
1500 91 4.58 50.4 4143.1 240 0.0193

ASTM B231
Code Name Area Number of Wires Diameter of Wire Approx. Overall Diameter Unit Weight Nominal Breaking Load Nominal DC Resistance at 20ºC
Nominal Actual
AWG or MCM mm2 No. mm mm kg/km kN ohm/km
PEACHBELL 6 13.3 7 1.56 4.68 36.6 2.53 2.1606
ROSE 4 21.1 7 1.96 5.88 58.2 3.91 1.3619
IRIS 2 33.6 7 2.47 7.41 92.6 5.99 0.855
PANSY 1 42.4 7 2.78 8.34 116.6 7.3 0.6779
POPPY 1/0 53.5 7 3.12 9.36 147.2 8.84 0.5373
ASTER 2/0 67.4 7 3.5 10.5 185.7 11.1 0.4262
PHLOX 3/0 85 7 3.93 11.79 233.9 13.5 0.3379
OXLIP 4/0 107.2 7 4.42 13.26 295.2 17 0.268
VALERIAN 250 126.7 19 2.91 14.55 348.6 20.7 0.2268
SNEEZEWORT 250 126.7 7 4.8 14.4 348.8 20.1 0.2268
LAUREL 266.8 135.2 19 3.01 15.05 372.2 22.1 0.2126
DAISY 266.8 135.2 7 4.96 14.88 372.3 21.4 0.2126
PEONY 300 152 19 3.19 15.95 418.3 24.3 0.189
TULIP 336.4 170.5 19 3.38 16.9 469.5 27.3 0.1686
DAFFODIL 350 177.3 19 3.45 17.25 487.9 28.4 0.1621
CANNA 397.5 201.4 19 3.67 18.35 554.9 31.6 0.1427
GOLDENTUFT 450 228 19 3.91 19.55 627.6 35 0.126
SYRINGA 477 241.7 37 2.88 20.16 664.8 38.6 0.1189
COSMOS 477 241.7 19 4.02 20.1 664.8 37 0.1189
HYACINTH 500 253.3 37 2.95 20.65 696.8 40.5 0.1134
ZINNIA 500 253.3 19 4.12 20.6 697.1 38.9 0.1134
MISTLETOE 556.5 282 37 3.12 21.84 775.7 44.3 0.1019
DAHLIA 556.5 282 19 4.35 21.75 775.8 43.3 0.1019
MEADOWSWEET 600 304 37 3.23 22.61 836.3 47.5 0.0945
ORCHID 636 322.3 37 3.33 23.31 886.9 50.4 0.0892
HEUCHERA 650 329.4 37 3.37 23.59 907.4 51.7 0.0872
FLAG 700 354.7 61 2.72 24.48 975.8 57.1 0.081
VERBENA 700 354.7 37 3.49 24.43 975.7 55.4 0.081
NASTURTIUM 715.5 362.6 61 2.75 24.75 998.5 58.4 0.0793
VIOLET 715.5 362.6 37 3.53 24.71 998.5 56.7 0.0793
 
Code Name Area Number of Wires Diameter of Wire Approx. Overall Diameter Unit Weight Nominal Breaking Load Nominal DC Resistance at 20ºC
Nominal Actual
AWG or MCM mm2 No. mm mm kg/km kN ohm/km
CATTAIL 750 380 61 2.82 25.38 1046 60.3 0.0756
PETUNIA 750 380 37 3.62 25.34 1046 58.6 0.0756
LILAC 795 402.8 61 2.9 26.1 1110 63.8 0.0713
ARBUTUS 795 402.8 37 3.72 26.04 1109 61.8 0.0713
SNAPDRAGON 900 456 61 3.09 27.81 1256 70.8 0.063
COCKSCOMB 900 456 37 3.96 27.72 1256 68.4 0.063
GOLDENROD 954 483.4 61 3.18 28.62 1331 75 0.0594
MAGNOLIA 954 483.4 37 4.08 28.56 1331 72.6 0.0594
CAMELLIA 1000 506.7 61 3.25 29.25 1394 78.3 0.0567
HAWKWEED 1000 506.7 37 4.18 29.26 1395 76.2 0.0567
LARKSPUR 1033.5 523.7 61 3.31 29.79 1442 81.3 0.0549
BLUEBELL 1033.5 523.7 37 4.25 29.75 1441 78.8 0.0549
MARIGOLD 1113 564 61 3.43 30.87 1553 87.3 0.0509
HAWTHORN 1192.5 604.2 61 3.55 31.95 1662 93.5 0.0476
NARCISSUS 1272 644.5 61 3.67 33.03 1774 98.1 0.0446
COLUMBINE 1351 684.6 61 3.78 34.02 1884 104 0.042
CARNATION 1431 725.1 61 3.89 35.01 1997 108 0.0396
GLADIOLUS 1510.5 765.4 61 4 36 2108 114 0.0375
COREOPSIS 1590 805.7 61 4.1 36.9 2216 120 0.0357
JESSAMINE 1750 886.7 61 4.3 38.7 2442 132 0.0324
COWSLIP 2000 1013 91 3.77 41.47 2787 153 0.0284
SAGEBRUSH 2250 1140 91 3.99 43.89 3166 167 0.0255
LUPINE 2500 1267 91 4.21 46.31 3519 186 0.0229
BITTERROOT 2750 1393 91 4.42 48.62 3872 205 0.0208
TRILLIUM 3000 1520 127 3.9 50.7 4226 223 0.0191
BLUEBONNET 3500 1773 127 4.22 54.86 4977 261 0.0165

BS EN 50182 (Germany)
Code Old Code Area No. of Wires Diameter Mass per Unit Length Rated Strength DC
Wire Cond. Resistance
mm2 mm mm kg/km kN Ω/km
16-AL1 16 15.9 7 1.7 5.1 43.4 3.02 1.7986
24-AL1 25 24.2 7 2.1 6.3 66.3 4.36 1.1787
34-AL1 35 34.4 7 2.5 7.5 93.9 6.01 0.8317
49-AL1 50 49.5 7 3 9 135.2 8.41 0.5776
48-AL1 50 48.3 19 1.8 9 132.9 8.94 0.5944
66-AL1 70 65.8 19 2.1 10.5 180.9 11.85 0.4367
93-AL1 95 93.3 19 2.5 12.5 256.3 16.32 0.3081
117-AL1 120 117 19 2.8 14 321.5 19.89 0.2456
147-AL1 150 147.1 37 2.25 15.8 405.7 26.48 0.196
182-AL1 185 181.6 37 2.5 17.5 500.9 31.78 0.1588
243-AL1 240 242.5 61 2.25 20.3 671.1 43.66 0.1193
299-AL1 300 299.4 61 2.5 22.5 828.5 52.4 0.0966
400-AL1 400 400.1 61 2.89 26 1107.1 68.02 0.0723
500-AL1 500 499.8 61 3.23 29.1 1382.9 82.47 0.0579
626-AL1 625 626.2 91 2.96 32.6 1739.7 106.45 0.0464
802-AL1 800 802.1 91 3.35 36.9 2228.3 132.34 0.0362
1000-AL1 1000 999.7 91 3.74 41.1 2777.3 159.95 0.0291

BS EN 50182 ( United Kingdom)
Code Old Area   Diameter Mass per Rated DC
code No.of Wire Cond. Unit length Strength Resistance
  mm2 wires mm mm kg/km kN Ω/km
23-AL1 MIDGE 23.3 7 2.06 6.18 63.8 4.2 1.2249
27-AL1 GNAT 26.9 7 2.21 6.63 73.4 4.83 1.0643
37-AL1 MOSQUITO 36.9 7 2.59 7.77 100.8 6.27 0.7749
43-AL1 LADYBIRD 42.8 7 2.79 8.37 117 7.28 0.6678
53-AL1 ANT 52.8 7 3.1 9.3 144.4 8.72 0.5409
64-AL1 FLY 63.6 7 3.4 10.2 173.7 10.49 0.4497
74-AL1 BLUEBOTTLE 73.6 7 3.66 11 201.3 11.78 0.388
79-AL1 EARWIG 78.6 7 3.78 11.3 214.7 12.57 0.3638
84-AL1 GRASSHOPPER 84.1 7 3.91 11.7 229.7 13.45 0.34
96-AL1 CLEGG 95.6 7 4.17 12.5 261.3 15.3 0.2989
106-AL1 WASP 106 7 4.39 13.2 289.6 16.95 0.2697
106-AL1 BEETLE 106.4 19 2.67 13.4 292.4 18.08 0.2701
132-AL1 BEE 132 7 4.9 14.7 360.8 21.12 0.2165
158-AL1 HORNET 157.6 19 3.25 16.3 433.2 26.01 0.1823
186-AL1 CATERPILLAR 185.9 19 3.53 17.7 511.1 29.75 0.1546
213-AL1 CHAFER 213.2 19 3.78 18.9 586 34.12 0.1348
238-AL1 SPIDER 237.6 19 3.99 20 652.9 38.01 0.121
266-AL1 COCKROACH 265.7 19 4.22 21.1 730.4 42.52 0.1081
323-AL1 BUTTERFLY 322.7 19 4.65 23.3 886.8 51.63 0.0891
373-AL1 MOTH 373.1 19 5 25 1025.3 59.69 0.077
372-AL1 DRONE 372.4 37 3.58 25.1 1027.1 59.59 0.0774
415-AL1 CENTIPEDE 415.2 37 3.78 26.5 1145.1 66.43 0.0695
486-AL1 MAYBUG 486.1 37 4.09 28.6 1340.6 77.78 0.0593
530-AL1 SCORPION 529.8 37 4.27 29.9 1461.2 84.77 0.0544
628-AL1 CICADA 628.3 37 4.65 32.6 1732.9 100.54 0.0459

AS 1531
Code Name Stranding Approx. Cross- Approx. Mass Calculated Equiv. D.C.
and Wire Overall Diameter sectional Breaking Aluminium Area Resistance  at 20ºC
Diameter   Area Load    
      (CBL)    
mm mm mm2 kg/km KN mm2 Ω/km
Leo 7/2.50 7.5 34.36 94.3 5.71 33.9 0.833
Leonids 7/2.75 8.25 41.58 113 6.72 41.1 0.689
Libra 7/3.00 9 49.48 135 7.98 48.9 0.579
Mars 7/3.75 11.3 77.28 211 11.8 76.3 0.37
Mercury 7/4.50 13.5 111.3 304 16.9 110 0.258
Moon 7/4.75 14.3 124 339 18.9 122 0.232
Neptune 19/3.25 16.3 157.6 433 24.7 154 0.183
Orion 19/3.50 17.5 182.8 503 28.7 180 0.157
Pluto 19/3.75 18.8 209.8 576 31.9 206 0.137
Saturn 37/3.00 21 261.6 721 42.2 256 0.11
Sirius 37/3.25 22.8 307 845 48.2 301 0.094
Taurus 19/4.75 23.8 336.7 924 51.3 331 0.0857
Triton 37/3.75 26.3 408.5 1120 62.2 400 0.0706
Uranus 61/3.25 29.3 506.1 1400 75.2 495 0.0572
Ursula 61/3.50 31.5 586.9 1620 87.3 574 0.0493
Venus 61/3.75 33.8 673.4 1860 97.2 659 0.0429
Durable High Conductivity IEC AAC BS AC Conductor for Energy Solutions
Industry Solutions
Power grid
New energy
Building
Industry
Marine cable
Telecommunication
Railway
Instrument


Our Certificate
Durable High Conductivity IEC AAC BS AC Conductor for Energy Solutions
Company Information


Durable High Conductivity IEC AAC BS AC Conductor for Energy SolutionsDurable High Conductivity IEC AAC BS AC Conductor for Energy SolutionsDurable High Conductivity IEC AAC BS AC Conductor for Energy SolutionsDurable High Conductivity IEC AAC BS AC Conductor for Energy Solutions
FAQ

1. Q:Are you a factory or trading company?
A: Manufacturing base in Henan ,China, with more than 150 workers.

2. Q:How can I visit there?
A: Sure,lf you need,we will arrange the driver to pick you up.

3. Q:How can I get some samples?
A: Contact me on below,Determine sample and address for shipping.

4. Q:Have you ever supplied cables to our country?
A: Xunda Cable have been sold to over 30 countries and regions in the world. you cancontact me for details.

5. Q:What is your MOQ?
A: MOQ Normally 1km for insulated cables(1 ton for bare conductor).Please contact mefor detail info if you have specific cable requirement.

6. Q:When can l get the price?
A: Usually quote within 3hours after we get your inquiry.

7. Q:How long is your delivery time?
A: According to your order's quantity.Usually our lead time is 3 - 20 working days.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier