Spaced Aerial Cable -SAC
DESCRIPTION
The conductors are stranded,circular compressed aluminum. The conductor screen is the extruded Semi-conducting conductor shield in Black. The inner Insulation is mainly natural color thermoplastic polyethylene (PE) or cross-linked polyethylene (XLPE). And the outer Insulation is mainly thermoplastic polyethylene (PE) or cross-linked polyethylene (XLPE) in Black or Grey with Weather or UV resistant. This standard covers both thermoplastic and cross linked polyethylene constructions, rated for 75°C or 90°C normal service temperature.
APPLICATION
This kind of spaced aerial cable ( SAC cable) is used for aerial power tranmission at 15/25/35 maximum system voltage. the phase to phase voltage is 10/20/33KV.
CONSTRUCTION
Conductor: Hard drawn aluminium wire according to the IEC 60228 standard. |
Conductor screen: XLPE compound |
Insulation: XLPE ( crosslinked polyethylene) |
Jacket: Black XLPE |
SPECIFICATIONS
• ICEA S-66-524
Cross-Linked-Thermosetting-Polyethylene-Insulated Wire and Cable for The Transmission and Distribution of Electrical Energy
• GB/T 14049 (Equal to IEC 60502-2)
Aerial Insulated Cables For Rated Voltage of 10kV
IEC 60502-2; ICEA S 66-524 Standards
15kV SAC Cable
Nominal Size |
Min.No. |
Covering Thickness |
Cable Diameter |
Min. Breaking Load |
Weight |
of Wires |
Conductor Shield |
Inner Layer |
Outer Layer |
mm2 |
No. |
mm |
mm |
mm |
mm |
N |
kg/km |
3-Layer 15kV AAC/XLPE/XLPE |
25 |
6 |
0.6 |
1.91 |
1.91 |
15.2 |
3762 |
218 |
35 |
6 |
0.6 |
1.91 |
1.91 |
16.2 |
5177 |
258 |
50 |
6 |
0.6 |
1.91 |
1.91 |
17.3 |
7011 |
307 |
70 |
12 |
0.6 |
1.91 |
1.91 |
19 |
10354 |
387 |
95 |
15 |
0.6 |
1.91 |
1.91 |
20.8 |
13727 |
482 |
120 |
15 |
0.6 |
1.91 |
1.91 |
22 |
17339 |
564 |
150 |
15 |
0.6 |
1.91 |
1.91 |
23.7 |
21033 |
660 |
185 |
30 |
0.6 |
1.91 |
1.91 |
25.3 |
26732 |
780 |
240 |
30 |
0.6 |
1.91 |
1.91 |
27.6 |
34679 |
968 |
Nominal Size |
Min. No. |
Covering Thickness |
Cable Diameter |
Min. Breaking Load |
Weight |
of Wires |
Conductor Shield |
Inner Layer |
Outer Layer |
mm2 |
No. |
mm |
mm |
mm |
mm |
N |
kg/km |
3-Layer 15kV AAC/XLPE/HDPE |
25 |
6 |
0.6 |
1.91 |
1.91 |
15.2 |
3762 |
221 |
35 |
6 |
0.6 |
1.91 |
1.91 |
16.2 |
5177 |
261 |
50 |
6 |
0.6 |
1.91 |
1.91 |
17.3 |
7011 |
310 |
70 |
12 |
0.6 |
1.91 |
1.91 |
19 |
10354 |
390 |
95 |
15 |
0.6 |
1.91 |
1.91 |
20.8 |
13727 |
486 |
120 |
15 |
0.6 |
1.91 |
1.91 |
22 |
17339 |
568 |
150 |
15 |
0.6 |
1.91 |
1.91 |
23.7 |
21033 |
664 |
185 |
30 |
0.6 |
1.91 |
1.91 |
25.3 |
26732 |
785 |
240 |
30 |
0.6 |
1.91 |
1.91 |
27.6 |
34679 |
973 |
25kV SAC Cable
Nominal Size |
Min. No. |
Covering Thickness |
Cable Diameter |
Min. Breaking Load |
Weight |
of Wires |
Conductor Shield |
Inner Layer |
Outer Layer |
mm2 |
No. |
mm |
mm |
mm |
mm |
N |
kg/km |
3-Layer 25kV AAC/XLPE/XLPE |
25 |
6 |
0.7 |
3.18 |
3.18 |
20.1 |
3762 |
351 |
35 |
6 |
0.7 |
3.18 |
3.18 |
21.1 |
5177 |
398 |
50 |
6 |
0.7 |
3.18 |
3.18 |
22.2 |
7011 |
455 |
70 |
12 |
0.7 |
3.18 |
3.18 |
23.9 |
10354 |
548 |
95 |
15 |
0.7 |
3.18 |
3.18 |
25.7 |
13727 |
657 |
120 |
15 |
0.7 |
3.18 |
3.18 |
26.9 |
17339 |
748 |
150 |
15 |
0.7 |
3.18 |
3.18 |
28.6 |
21033 |
856 |
185 |
30 |
0.7 |
3.18 |
3.18 |
30.2 |
26732 |
989 |
240 |
30 |
0.7 |
3.18 |
3.18 |
32.5 |
34679 |
1195 |
Nominal Size |
Min. No. |
Covering Thickness |
Cable Diameter |
Min. Breaking Load |
Weight |
of Wires |
Conductor Shield |
Inner Layer |
Outer Layer |
mm2 |
No. |
mm |
mm |
mm |
mm |
N |
kg/km |
3-Layer 25kV AAC/XLPE/HDPE |
25 |
6 |
0.7 |
3.18 |
3.18 |
20.1 |
3762 |
356 |
35 |
6 |
0.7 |
3.18 |
3.18 |
21.1 |
5177 |
404 |
50 |
6 |
0.7 |
3.18 |
3.18 |
22.2 |
7011 |
461 |
70 |
12 |
0.7 |
3.18 |
3.18 |
23.9 |
10354 |
555 |
95 |
15 |
0.7 |
3.18 |
3.18 |
25.7 |
13727 |
664 |
120 |
15 |
0.7 |
3.18 |
3.18 |
26.9 |
17339 |
755 |
150 |
15 |
0.7 |
3.18 |
3.18 |
28.6 |
21033 |
864 |
185 |
30 |
0.7 |
3.18 |
3.18 |
30.2 |
26732 |
997 |
240 |
30 |
0.7 |
3.18 |
3.18 |
32.5 |
34679 |
1203 |
35kV SAC Cable
Nominal Size |
Min. No. |
Covering Thickness |
Cable Diameter |
Min. Breaking Load |
Weight |
of Wires |
Conductor Shield |
Inner Layer |
Outer Layer |
mm2 |
No. |
mm |
mm |
mm |
mm |
N |
kg/km |
3-Layer 35kV AAC/XLPE/XLPE |
25 |
6 |
0.7 |
4.45 |
3.18 |
22.6 |
3762 |
433 |
35 |
6 |
0.7 |
4.45 |
3.18 |
23.6 |
5177 |
485 |
50 |
6 |
0.7 |
4.45 |
3.18 |
24.7 |
7011 |
545 |
70 |
12 |
0.7 |
4.45 |
3.18 |
26.4 |
10354 |
645 |
95 |
15 |
0.7 |
4.45 |
3.18 |
28.2 |
13727 |
761 |
120 |
15 |
0.7 |
4.45 |
3.18 |
29.4 |
17339 |
856 |
150 |
15 |
0.7 |
4.45 |
3.18 |
31.1 |
21033 |
971 |
185 |
30 |
0.7 |
4.45 |
3.18 |
32.7 |
26732 |
1110 |
240 |
30 |
0.7 |
4.45 |
3.18 |
35 |
34679 |
1324 |
Nominal Size |
Min. No. |
Covering Thickness |
Cable Diameter |
Min. Breaking Load |
Weight |
of Wires |
Conductor Shield |
Inner Layer |
Outer Layer |
mm2 |
No. |
mm |
mm |
mm |
mm |
N |
kg/km |
3-Layer 35kV AAC/XLPE/HDPE |
25 |
6 |
0.7 |
4.45 |
3.18 |
22.6 |
3762 |
439 |
35 |
6 |
0.7 |
4.45 |
3.18 |
23.6 |
5177 |
491 |
50 |
6 |
0.7 |
4.45 |
3.18 |
24.7 |
7011 |
552 |
70 |
12 |
0.7 |
4.45 |
3.18 |
26.4 |
10354 |
652 |
95 |
15 |
0.7 |
4.45 |
3.18 |
28.2 |
13727 |
768 |
120 |
15 |
0.7 |
4.45 |
3.18 |
29.4 |
17339 |
864 |
150 |
15 |
0.7 |
4.45 |
3.18 |
31.1 |
21033 |
980 |
185 |
30 |
0.7 |
4.45 |
3.18 |
32.7 |
26732 |
1119 |
240 |
30 |
0.7 |
4.45 |
3.18 |
35 |
34679 |
1334 |
Industry Solutions
Power grid
New energy
Building
Industry
Marine cable
Telecommunication
Railway
Instrument
Our Certificate
Quality Testing

Packaging & Shipping

Company Information

Henan Xunda Cable Co., Ltd., established in 2001, is a manufacturer specializing in the R&D and production of high-quality wires and cables. With over 20 years of experience, we provide reliable cable solutions, strengthened by our subsidiary, Xina Cable, for global reach and better service.
We produce a wide range of cables, including AAC, AAAC, ACSR, Power Cables (up to 35KV), Control Cables, Concentric Cables, Solar Cables, Building Wires, Nylon Wires, LSOH wires, and Branch Cables. Our products are widely used in power transmission, petrochemicals, metallurgy, construction, and infrastructure projects.
Located in the Industrial Zone of Gongyi, Zhengzhou City, Henan, China, our 30,000m2 factory employs over 100 staff, including 20 senior technicians. With 30+ advanced production lines including high-speed drawing, stranding, and extrusion equipment, our daily bare conductor production capacity achieves more than 100 tons. Our strict quality control system and full-scale testing equipment ensure all products comply with ISO9001, CCC, and international standards, ensuring safety, durability, and reliability.
We have exported to over 20 countries, including Chile, Dominica, Panama, Colombia, Nicaragua, Peru, Philippines, Vietnam, Malaysia, Australia, PNG, Burundi, Tanzania, Madagascar, Angola among others. We provide 48-hour technical support, flexible payments, and efficient logistics for smooth transactions and timely delivery.
Our mission: Transmit Light, Connect World, Create Win-win, Grow together!
FAQ
Your questions illuminate better solutions- we welcome any additional inquiries.
Q1: Are you a factory or trading company?
A1: Manufacturing base in Henan ,China, with more than 150 workers.
Q2: How can I visit there?
A2: Sure,lf you need,we will arrange the driver to pick you up.
Q3: How can I get some samples?
A3: Contact me on below, determine sample and address for shipping.
Q4: What is your MOQ?
A4: MOQ Normally 1km for insulated cables(1 ton for bare conductor). Please contact me for detail info if you have specific cable requirement.
Q5: Have you ever supplied cables to our country?
A5: Xunda Cable have been sold to over 30 countries and regions in the world. you can contact me for details.
Q6: When can l get the price?
A6: Usually quote within 3 hours after we get your inquiry.
Q7: How long is your delivery time?
A7: According to your order's quantity.Usually our lead time is 3 - 20 working days.
Q8: How do you guarantee quality?
A8: 100% inspection before delivery; Full set of testing equipment.